journal article·2020-01Open access

Corrosion resistance of electrified railway tunnels made of steel fibre reinforced concrete

Kangkang Tang, Stephen Wilkinson

Abstract

Abstract Steel fibre reinforced concrete (SFRC) has been widely used in the construction of buildings, roads and bridges where high compressive and/or tensile strength is preferred. From a structural perspective, SFRC is an ideal substitute for conventional steel reinforcement in railway tunnel construction. However, it is still not clear whether discontinuous steel fibres can pick up and transfer stray current, especially stray alternating current (AC), and lead to similar corrosive attacks as occur in conventional steel reinforcement. The development of suitable approaches for the assessment of the corrosion susceptibility of SFRC under stray AC conditions is a primary aim of this paper. The analytical model, validated by experimental data, indicates that SFRC has an inherent corrosion resistance to stray AC due to the electrical double layer developed on the steel surface. The presence of a small amount of chlorides (0.3 mol/L in the concrete pore solution or 2% by mass of cement) however reduces its corrosion resistance.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (58)

Show source-provided references
1. Wikipedia, 25 kV AC railway electrification. https://en.wikipedia.org/wiki/25_kV_AC_railway_electrification, 2017. (Accessed 29 June 2018).
2. Crossrail, Europe's largest construction project. http://www.crossrail.co.uk/construction/, 2017. (Accessed 27 June 2017).
3. Railway-technology, High Speed 2 (HS2) railway. http://www.railway-technology.com/projects/high-speed-2-hs2/, 2017. (Accessed 27 June 2017).
4. Wikipedia, Turin-Lyon high-speed railway. https://en.wikipedia.org/wiki/Turin%E2%80%93Lyon_high-speed_railway, 2017. (Accessed 29 June 2018).
5. Wikipedia, Gotthard Base Tunnel. https://en.wikipedia.org/wiki/Gotthard_Base_Tunnel, 2016. (Accessed 29 June 2018).
6. Corrosion behaviour of steel in concrete in the presence of stray current10.1016/j.corsci.2006.05.048 ↗
7. National Physical Laboratory (UK), Estimate of annual costs attributable to corrosion of reinforced concrete structures in the United Kingdom. www.npl.co.uk. (Accessed 18 November 2016).
8. A. Steel, Design standards stray current management, Office of Rail Regulation, 2010.
9. Prinz · 1992
10. Ragault · 1998
11. Wakeling · 1998
12. BSI · 2013
13. Understand the AC induced pitting corrosion on pipelines in both high pH and neutral pH carbonate/bicarbonate solutions10.1016/j.corsci.2014.04.030 ↗
14. Effect of alternating current on corrosion and effectiveness of cathodic protection of pipelines10.1179/1879139511Y.0000000021 ↗
15. Effects of curing temperature on the hydration of GGBS blended concrete and the use of electron microscope particle analysis10.1680/jadcr.16.00175 ↗
16. ACI · 2008
17. Corrosion resistance of steel fibre reinforced concrete – a literature review10.1016/j.cemconres.2017.05.016 ↗
18. A proposal of AC corrosion mechanism of carbon steel in cathodic protection condition (PhD thesis)
19. Cao · 2008
20. A revised model for predicting corrosion of materials induced by alternating voltages10.1016/S0010-938X(96)00065-0 ↗
21. Effect of alternating voltage on corrosion of X80 and X100 steels in a chloride containing solution – investigated by AC voltammetry technique10.1016/j.corsci.2014.05.012 ↗
22. A theoretical study of AC-induced corrosion considering diffusion phenomena10.1016/S0010-938X(97)00139-X ↗
23. Effects of alternating current interference on the cathodic protection for API 5L X60 pipeline steel10.1016/j.jngse.2016.10.021 ↗
24. Experimental study on stray current corrosion of coated pipeline steel10.1016/j.jngse.2015.10.022 ↗
25. Development of a real-time AC/DC data acquisition technique for studies of AC corrosion of pipelines10.1016/j.corsci.2012.04.038 ↗
26. AC corrosion – part 2: parameters influencing corrosion rate10.1016/j.corsci.2009.11.012 ↗
27. Federation internationale du beton, Fib Model Code for Concrete Structures 2010, Ernst & Sohn, 2013.
28. J. Greenhalgh, 20 years of fibre concrete linings in the UK. https://www.tunneltalk.com/Fibrecrete-Oct10-20-years-of-fibrecrete-in-the-UK.php, 2010. (Accessed 8 July 2018).
29. Channel tunnel rail link section 2: thames tunnel
30. Lin · 2005
31. Tunnel-online, Steel-fibre-reinforced segmental linings: State-of-the-art and completed projects. http://www.tunnel-online.info/en/artikel/tunnel_2011-01_Steel-fibre-reinforced_segmental_linings_State-of-the-art_and_completed_1076896.html, 2011. (Accessed 14 October 2018).
32. W. Angerer, M. Chappell, Design of Steel Fibre Reinforced Segmental Lining for the Gold Coast Desalination Tunnels, Melbourne, Australia, 2008.
33. Lining design for the district heating tunnel in Copenhagen with steel fibre reinforced concrete segments10.1016/j.tust.2007.11.001 ↗
34. Steel fibre reinforced concrete for tunnel lining segments
35. Keen · 2010
36. The monitor and control system of stray current corrosion in metro
37. A. Yadav, Traction choices: overhead ac vs third rail dc. http://www.railjournal.com/index.php/rolling-stock/traction-choices-overhead-ac-vs-third-rail-dc.html, 2013. (Accessed 17 September 2018).
38. EIS analysis on chloride-induced corrosion behavior of reinforcement steel in simulated carbonated concrete pore solutions10.1016/j.jelechem.2012.09.012 ↗
39. Stray current induced corrosion to steel fibre reinforced concrete10.1016/j.cemconres.2017.08.004 ↗
40. Influence of chloride concentration and pre-passivation on the pitting corrosion resistance of low-alloy reinforcing steel in simulated concrete pore solution10.1016/j.conbuildmat.2016.02.107 ↗
41. Effects of AC-interference on chloride-induced corrosion of reinforced concrete10.1016/j.conbuildmat.2017.01.087 ↗
42. Chloride content and pH value in the pore solution of concrete under carbonation10.1631/jzus.A1200187 ↗
43. EIS monitoring of embedded steel in alkali activated concrete exposed to carbonation10.4067/S0718-50732011000100005 ↗
44. The electrochemical behaviour of steel rebars in concrete: an Electrochemical Impedance Spectroscopy study of the effect of temperature10.1016/j.electacta.2013.12.012 ↗
45. Corrosion behavior of stainless steel rebars embedded in concrete: an electrochemical impedance spectroscopy study10.1016/j.electacta.2013.11.154 ↗
46. The corrosion behaviour of reinforced concrete using EIS tests
47. EIS analysis on stress corrosion initiation of pipeline steel under disbonded coating in near-neutral pH simulated soil electrolyte10.1016/j.corsci.2016.04.006 ↗
48. Gamry, Gamry Echem Analyst. http://www.gamry.com/support/software/dc105-dc-corrosion-software/, 2015. (Accessed 20 October 2018).
49. Roberge · 2008
50. AC corrosion – part 1: effects on overpotentials of anodic and cathodic processes10.1016/j.corsci.2009.10.005 ↗
51. Corrosion by alternating current: polarization of mild steel in neutral electrolytes10.1149/1.2120068 ↗
52. Experimental investigation on the effect of corrosion on the bond between reinforcing steel bars and fibre reinforced geopolymer concrete10.1016/j.istruc.2018.03.013 ↗
53. Experimental study on the properties of corroded steel fibres10.1016/j.conbuildmat.2014.12.082 ↗
54. Effect of AC current density on stress corrosion cracking behavior of X80 pipeline steel in high pH carbonate/bicarbonate solution10.1016/j.electacta.2013.11.149 ↗
55. A periodic voltage modulation effect on the corrosion oF Cu-Ni alloy10.1016/0010-938X(94)P4303-X ↗
56. Yunovich · 2004 · 183
57. V. Nielsen, P. Cohn, AC corrosion and electrical equivalent diagrams, European Committee for the Study of Corrosion and Protection of Pipes and Pipelines Systems Drinking Water, Waste Water, Gas and Oil, UK, 2000.
58. A study on chloride-induced depassivation of mild steel in simulated concrete pore solution10.1016/S0008-8846(02)00895-5 ↗