Influence of pre-wetting, non-shrink grout, and scaling on the compressive strength of grouted concrete masonry prisms
Source abstract
Abstract
Abstract This study experimentally investigates the influence of pre-wetting of dry masonry prisms, non-shrink grout, and grout strength on the axial compressive stress-strain response of grouted masonry prisms built using half-scale and full-scale concrete masonry blocks. To achieve the aims of this study, a total of forty-two concrete-masonry prisms were built and tested under concentric axial load. The results showed that grouting of dry masonry prisms rendered a non-proportional increase in the prism compressive strength, whereas grouting of wet masonry prisms exhibited a significant increase in the masonry prism compressive strength. Masonry prisms constructed with non-shrink grout showed, on average, an increase in the compressive strength when compared to masonry prisms constructed with regular grout. Wetting of masonry prisms before grouting was found to enhance the compressive strength of masonry prisms. Half-scale masonry prisms showed a comparable modulus of elasticity and strain at peak strength to their full-scale counterparts. However, some discrepancies in the compressive strength and post-peak behaviour were observed. Superposition of the masonry shell and the grout core strengths was found to highly overestimate dry grouted masonry prism compressive strength, whereas wet masonry prisms demonstrated excellent agreement with superposition values. Wetting of dry masonry prisms is a promising construction procedure that significantly enhanced the compressive strength of grouted masonry; however, further research is needed to determine the proper wetting scheme and to ensure consistent results that can be quantified.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Microbial Applications in Construction Materials · Building materials and conservation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. CSA, “Design of masonry structures.” S304-14, Canadian Standards Association, a, Mississauga, ON, Canada, 2014.
2. ACI 530-05, Building Code Requirements for Masonry Structures., TMS 402-11. (2011) 158.
3. Drysdale · 2005
4. Comparing masonry compressive strength in various codes
5. Gayed · 2011
6. Y. Korany, Masonry Chair Report No. 105-2012 Concrete masonry compressive strength using the unit strength method for grouted masonry, (2012).
7. Relationship between the compressive strength of concrete masonry and the compressive strength of concrete masonry units
8. Small-scale modelling of concrete masonry using ½-scale units: A preliminary study
9. Compressive strength of grouted and un-grouted concrete block masonry
10. Behavior of concrete block masonry under axial compression
11. Stress-strain behavior of C-shaped confined concrete masonry boundary elements of reinforced masonry shear walls10.1061/(ASCE)ST.1943-541X.0002120 ↗
12. Mohamed · 2018
13. Effect of Grouting on the Strength Characteristics of Concrete Block Masonry
14. Concrete masonry prism testing
15. Influencing Factors on Prism Strength of Grouted Masonry and Fracture Mechanism under
16. J.C. Scrivener, L.R. Baker, Factors Influencing Grouted Masonry Prism Compressive Strength, (1988) 874–883.
17. C. Yao, N.D. Nathan, Axial Capacity of Grouted Concrete Masonry.pdf, in: 5th Can. Mason. Symp., Vancouver, B.C., Canada, 1989.
18. Stress-strain curves for unconfined and confined concrete masonry
19. Study of the compressive strength of blockwork masonry
20. Influence of block geometry and grout type on compressive strength of block masonry.pdf
21. Joyal · 2014
22. Compressive strength of high-strength concrete masonry grouted prisms10.1016/j.conbuildmat.2019.01.037 ↗
23. Small-scale modeling of concrete block masonry structures
24. ASTM, Standard Test Method for Compressive Strength of Masonry Prisms, C1314-14, ASTM Int. 04 (2014) 1–9. doi:10.1520/C1314-14.2.
25. Blocfiller, Concrete masonry unit grout, Technical data sheet, March 2015, (2015) 1–3. https://www.daubois.com/docs/blocfiller-en.pdf, (accessed April 6, 2018).
26. Quikrete®non-shrink precision Grout, Product No. 1585-00, Revised 28 August 2015, (2015) 1–2. https://www.quikrete.com/pdfs/data_sheet-non-shrink precision grout 1585-00.pdf, (accessed April 6, 2018).
27. SikaGrout®-212, Product Data Sheet Edition 12.2017/v1, 45 (2017) 1–3. https://can.sika.com/dms/getdocument.get/93842c32-adb3.../SikaGrout212_pds.pdf, (accessed February 8, 2018).
28. ASTM, Standard Test Method for Compressive Strength of Hydraulic Cement Mortars, C109/C109M, ASTM Int. (2013). doi:10.1520/C0109.
29. CSA · 2014
30. ASTM, Standard Test Method for Sampling and Testing Grout, C1019-14, AstmInternational. (2014) 1–5. doi:10.1520/C1019-11.2.
31. ASTM, Standard Test Methods for Sampling and Testing Concrete Masonry Units and Related Units, C140-15, ASTM Int. i (2015) 1–24. doi:10.1520/C0140.10.1520/C0140 ↗
32. G.R. Sturgeon, J. Longworth, J. Warwaruk, An Investigation of Reinforced Concrete Block Masonry Columns, Univ. Alberta Struct. Eng. Rep. No. 91. (1980).
33. ASTM C1437, Standard Test Method for Flow of Hydraulic Cement Mortar: C1437-13, ASTM Lnternational. i (2013) 7–8. doi:10.1520/C1437-13.2.
34. Suggested failure criteria for grouted concrete masonry under axial compression
35. Sarhat · 2016
36. Prediction of masonry compression strength.pdf
37. NCMA, Research Evaluation of Flexural Tensile Strength of Concrete Masonry, 1994.
38. A.H.P. Maurenbrecher, Effect of the test procedures on compressive strength of masonry prisms, in: Second Can. Mason. Symp., Ottawa, 1980: pp. 119–132.
39. Effect of dimensions on the compressive strength of concrete masonry prisms