journal article·2021-02

Structural performance of dowelled cross-laminated timber hold-down connections with increased row spacing and end distance

Justin R. Brown, Minghao Li

Publisher page

Abstract

Abstract This paper presents an experimental study to assess the structural performance of dowelled cross-laminated timber (CLT) hold-down connections that are critical components for a CLT shear wall under seismic loads. It aims to quantify the enhanced connection performance by increasing row spacing and end distance in the dowel layout compared with the standard spacing/distance specified by design standards. A total of 47 dowelled hold-down connection specimens with standard and increased row spacing and end distance in three-, five-, and seven-layer CLT layups were tested under monotonic and cyclic loading. Additional attempt was also made to investigate the benefits of applying screw reinforcement to deter the onset of potential brittle failure modes or mode cross-over. The increased row spacing and end distance provided comparable connection strength but significantly increased ductility. Displacement capacity and ductility increased by 35% and 20%, respectively and the effect was most pronounced in the five-layer CLT specimens. Dowel embedment tests were performed to verify the CLT Handbook equation and to determine theoretical overstrength. The maximum connection overstrength factor was 1.70 and the average was 1.61. Reinforcement by fully threaded inclined screws or the use of threaded dowels with nuts can further enhance the connection performance.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Bamboo properties and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (75)

Show source-provided references
1. Green · 2017
2. Dangel · 2016
3. Seismic reliability analysis of diagonal-braced and structural-panel- sheathed wood shear walls10.1061/(ASCE)ST.1943-541X.0000008 ↗
4. Seismic performance of post and beam timber buildings I: Model development and verification10.1007/s10086-011-1219-5 ↗
5. Seismic performance of post-and-beam timber buildings II: Reliability evaluations10.1007/s10086-011-1232-8 ↗
6. Seismic behaviour of Cross-Laminated Timber structures: A state-of-the-art review10.1016/j.engstruct.2018.05.060 ↗
7. Cross laminated timber (CLT): overview and development10.1007/s00107-015-0999-5 ↗
8. Cross-Laminated Timber for Seismic Regions: Progress and Challenges for Research and Implementation10.1061/(ASCE)ST.1943-541X.0001192 ↗
9. B. Dujic, J. Pucelj, R. Zarnic, Testing of racking behavior of massive wooden wall panels, in: Proc. CIB W18 Meet. Thirty-Seven, Edinburgh, Scotland, 2004.
10. Systematic experimental investigation to support the development of seismic performance factors for cross laminated timber shear wall systems10.1016/j.engstruct.2018.06.021 ↗
11. Experimental tests on cross-laminated timber joints and walls10.1680/stbu.13.00085 ↗
12. Cyclic behaviour of typical metal connectors for cross-laminated (CLT) structures10.1617/s11527-014-0278-7 ↗
13. Behaviour of Cross-Laminated Timber Panels under Cyclic Loads10.1007/978-94-007-7811-5_62 ↗
14. M. Popovski, J. Schneider, M. Schweinsteiger, Lateral load resistance of cross-laminated wood panels, in: WCTE 2010, Riva del Garda, Italy, 2010: pp. 3394–3403.
15. Challenges and solutions in the design of a 10 storey CLT building
16. Rothoblaas, WHT Angle brack for tensile loads, Cortaccia, Italy, 2019.
17. Strong-Tie · 2019
18. Ductility and overstrength of nailed CLT hold-down connections10.1016/j.engstruct.2020.110667 ↗
19. Experimental and numerical evaluation of hold-down connections on radiata pine Cross-Laminated-Timber shear walls: a case study in Chile10.1007/s00107-018-1365-1 ↗
20. Enhanced Seismic Performance of Timber Structures Using Resilient Connections: Full-Scale Testing and Design Procedure10.1061/(ASCE)ST.1943-541X.0002749 ↗
21. High-capacity hold-down for mass-timber buildings10.1016/j.conbuildmat.2018.01.019 ↗
22. Experimental assessment of a novel steel tube connector in cross-laminated timber10.1016/j.engstruct.2018.09.058 ↗
23. Structural performance of large-scale dowelled CLT connections under monotonic and cyclic loading10.1016/j.engstruct.2018.09.002 ↗
24. Design Approaches for CLT Connections10.22382/wfs-2018-038 ↗
25. Cross laminated timber (CLT): Design approaches for dowel-type fasteners and connections10.1016/j.engstruct.2018.05.032 ↗
26. Seismic analysis of multi-storey timber buildings braced with a CLT core and perimeter shear-walls10.1007/s10518-018-0467-9 ↗
27. Overstrength of dowelled CLT connections under monotonic and cyclic loading
28. A proposal for the capacity-design at wall- and building-level in light-frame and cross-laminated timber buildings10.1007/s10518-019-00578-4 ↗
29. Paulay · 1975
30. The Reality of Seismic Engineering in a Modern Timber World
31. Buchanan · 2016
32. CEN, EN12512: Timber structures: test methods : cyclic testing of joints made with mechanical fasteners : [including amendment A1:2005], European Committee for Standardization, Brussels, 2005.
33. General notes on ductility in timber structures10.1016/j.engstruct.2011.07.024 ↗
34. Performance-Based Engineering Provides Path to More Compelling Mass Timber Projects
35. Sesimic Design of Cross-Laminated Timber Buildings10.22382/wfs-2018-037 ↗
36. Seismic Performance Factors for Cross-Laminated Timber Shear Wall Systems in the United States10.1061/(ASCE)ST.1943-541X.0002718 ↗
37. The new provisions for the seismic design of timber buildings in Europe10.1016/j.engstruct.2018.04.090 ↗
38. Ductility in Timber Structures: Investigations on Over-Strength Factors, Springer, Dordrecht
39. Capacity design of traditional and innovative ductile connections for earthquake-resistant CLT structures10.1007/s10518-018-00536-6 ↗
40. 086, Engineering design in wood
41. Standards New Zealand · 1993
42. CEN, Eurocode 5: Design of timber structures-Part 1-1: General-Common rules and rules for buildings, EN1995-1-12004-11 + AC2006-06 + A12008-06 + A22014-05 Eurocode 5. (2014).
43. Timber Engineering: Principles for Deisng, KIT Scientific Publishing, Karlsruhe
44. Mode Cross-Over and Ductility of Dowelled LVL and CLT Connections under Monotonic and Cyclic Loading
45. Blaß · 2007
46. CEN, EN 14358:2016 - Timber structures - Calculation and verification of characteristic values, European Committee for Standardization (CEN), Brussels, Belgium, 2016.
47. Australian / New Zealand Standard, AS/NZS 4671: Steel reinforcing materials, In: Standards Australia, GPO Box 476, Sydney, NSW and Standards New Zealand, Private Bag 2439, Wellington, New Zealand, 2001.
48. Gagnon · 2011
49. Standards New Zealand · 1992
50. Standards New Zealand, DZ NZS AS 1720.1/V6.0 Timber Structures - Part 1: Design Methods (draft out for public consultation), (2018).
51. T. Uibel, H.J. Blaß, Edge joints with dowel type fasteners in cross laminated timber, in: Proc. CIB W18 Meet. Forty, Bled, Slovenia, 2007.
52. T. Uibel, H.J. Blaß, Load carrying capacity of joints with dowel type fasteners in solid wood panels, in: Proc. CIB W18 Meet. Thirty-Nine, Florence, Italy, 2006: pp. 191–202.
53. AWC, AWC, National Design Specifications for Wood Construction(ANSI/AWC NDS-2015), (2015).
54. Standards Australia, AS 1444-2007: Wrought alloy steels-standard hardenability (H) series and hardened and tempered to designated mechanical properties, Standards Australia, Sydney, Australia, 2007.
55. ISO16670:2003, Timber Structures - joints made with mechanical fasteners - quasi-static reversed-cyclic test method, The International Organization for Standardization, Geneva, Switzerland, 2003.
56. I. Smith, A. Asiz, M. Snow, Y.H. Chui, Possible Canadian / ISO Approach to Deriving Design Values From Test Data, in: Proc. CIB W18 Meet. Thirty-Nine, Florence, Italy, 2006.
57. CEN, Eurocode 8: Design of structures for earthquake resistance, European Committee for Standardization (CEN), Brussels, Belgium, 2005.
58. Theory of timber connections
59. Effective bending capacity of dowel-type fasteners
60. CEN, EN 26891 - Joints made with mechanical fasteners. General principles for the determination of strength and deformation characteristics, European Committee for Standardization (CEN), Brussels, Belgium, 1991.
61. CEN, EN 409 - Timber structures - Test methods - Determination of the yield moment of dowel type fasteners, European Committee for Standardization (CEN), Brussels, Belgium, 2009.
62. Analytical Derivation and Experimental Verification of Overstrength Factors of Dowel-type Timber Connections for Capacity Design Analytical Derivation and Experimental Verification of
63. Australian / New Zealand Standard, AS/NZS ISO 10984.1: Timber Structures -Dowel-type fasteners, In: Standards Australia, GPO Box 476, Sydney, NSW and Standards New Zealand, Private Bag 2439, Wellington, New Zealand, 2015.
64. American Society for Testing and Materials, ASTM D5764-97a - Standard test method for evaluating dowel-bearing strength of wood and wood-based prducts, West Conshohocken, PA, United States, 2013.
65. Embedment strength of smooth dowel-type fasteners in cross-laminated timber10.1016/j.conbuildmat.2019.117243 ↗
66. Effects of embedment side and loading direction on embedment strength of cross-laminated timber for smooth dowels10.1007/s00107-019-01490-z ↗
67. G. Flatscher, Evaluation and approximation of timber connection properties for displacement-based analysis of CLT wall systems, 2017.
68. C. Zhang, Reinforcement of Timber Dowel-Type Connections Using Self-Tapping Screws, (2018).
69. I. Bejtka, H.J. Blaß, Self-tapping Screws as Reinforcements in Connections with Dowel-type Fasteners, in: Work. Comm. W18 Timber Struct., Karlsruhe, Germany, 2005: p. 19.
70. C. Sandhaas, J.-W.G. van de Kuilen, Strength and stiffness of timber joints with very high strength steel dowels, Eng. Struct. 131 (2017) 394–404. https://doi.org/https://doi.org/10.1016/j.engstruct.2016.10.046.10.1016/j.engstruct.2016.10.046 ↗
71. N.L. Rahim, G.M. Raftery, P. Quenneville, Stiffness of Bolted Timber Connection, in: WCTE 2018 - World Conf. Timber Eng., Seoul, Republic of Korea, n.d.
72. Experimental testing of full-scale glulam frames with buckling restrained braces10.1016/j.engstruct.2020.111081 ↗
73. R. Jockwer, A. Jorissen, Stiffness and deformation of connections with dowel-type fasteners, 2018.
74. Modelling the variation in wood density of New Zealand-grown Douglas-fir
75. L.-M. Ottenhaus, M. Li, T. Smith, Analytical Method to Derive Overstrength of Dowel-Type Connections Overstrength components, in: Proc. INTER Meet. Fifty-One, Tallin, Estonia, 2018: pp. 1–12.