Behavior of post-tensioned dry-stack interlocking masonry shear walls under cyclic in-plane loading
Source abstract
Abstract
Abstract Dry-stacked interlocking masonry (DSIM) systems were developed worldwide to minimize the disadvantages of traditional masonry systems such as shrinkage, weak joints, and the need of skilled labors. Nevertheless, dry-stacked walls are recommended to be designed as reinforced and fully grouted. In this paper an experimental study conducted to evaluate the in-plane behavior of full-scale DSIM shear walls under cyclic in-plane loading and to explore the effectiveness of using post-tensioning (PT) instead of grout and reinforcement. A sliding control system to enhance the ductility of the DSIM system was developed. The test program consists of nine masonry shear walls constructed with three different types of locally available concrete masonry blocks (Conventional, Azar and Sparlock). The specimens were tested under reversed cyclic lateral load up to failure. The test results, including load displacement response, failure mode, modes of deformation, residual drift ratio, displacement ductility, wall stiffness, stiffness degradation, and energy dissipation are presented and discussed. The results showed that a similar behavior of Azar and conventional masonry systems in both reinforced and PT specimens. The utilization of PT with excluding the grout in DSIM shear walls improved the displacement ductility, effective stiffness and energy dissipation. Finally, the developed sliding control system in DSIM PT specimens increased the sliding contribution to 35% of total deformation, hence improved the displacement ductility.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Polymer composites and self-healing
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Development and performance evaluation of interlocking-block masonry10.1061/(ASCE)1076-0431(2000)6:2(45) ↗
2. Agrément-South-Africa, Agreement certificate 69/237, Pretoria, South Africa, (1996).
3. Structural behaviour of dry-stack interlocking block walling systems subject to in-plane loading
4. Ngowi · 2006
5. Behavior of the dry bed joint in the mortarless interlocking masonry system: an overview
6. Structural behavior of an interlocking masonry block
7. E. Gazzola, R. Drysdale, Strength and deformation properties of dry-stacked surface bonded low-density block masonry, in: Proc. Fifth Can. Mason. Symp. Vancouver, Canada. (1989) 609–18.
8. R. Drysdale, E. Gazzola, Strength and Deformation Properties of a Grouted, Dry-Stacked, Interlocking, Concrete Block System, Brick Block Mason. (1991) 164–171.
9. H. Harris, K. Oh, A. Hamid, Development of new interlocking and mortarless block masonry units for efficient building systems, in: Proc. 6th Can. Mason. Symp. Saskatoon, Canada (1992).
10. Strength and deformation capacity of laterally loaded masonry
11. Loading capacity of dry-stack masonry walls
12. Out-of-plane structural response of interlocking compressed earth block walls
13. To study the behavior of interlocking of masonry units/blocks10.9790/3021-04313947 ↗
14. Testing of flexure-dominated interlocking compressed earth block walls10.1016/j.conbuildmat.2015.02.080 ↗
15. Development of interlocking masonry bricks and its’ structural behaviour: a review paper10.1088/1755-1315/140/1/012127 ↗
16. Laursen · 2002
17. G.D. Wight, Seismic performance of a post-tensioned concrete masonry wall system, 2006. http://hdl.handle.net/2292/362 (accessed 9 September 2017).
18. Effects of tendon spacing on in-plane behavior of posttensioned masonry walls
19. Experimental Investigation of In-Plane Cyclic Response of Unbonded Posttensioned Masonry Walls
20. In-plane flexural strength of unbonded post-tensioned concrete masonry walls10.1016/j.engstruct.2017.01.016 ↗
21. Improved estimation of the reverse-cyclic behavior of fully-grouted masonry shear walls with unbonded post-tensioning10.1016/j.engstruct.2017.05.011 ↗
22. 2011
23. Kohail · 2015
24. Sokairege · 2016
25. Behavior of post-tensioned dry-stack interlocking masonry walls under out of plane loading10.1016/j.conbuildmat.2016.12.071 ↗
26. ASTM-C270, Standard Specification for Mortar for Unit Masonry, West Conshohocken, PA ASTM Int. (2004) 1–13.
27. Strength and stiffness of masonry shear walls with openings
28. Seismic design parameters for special masonry structural walls detailed with confined boundary elements
29. Elshafie · 1997
30. Evaluation of ductility of structures and structural assemblages from laboratory testing
31. Paulay · 1992
32. Performance based seismic design10.5459/bnzsee.33.3.325-346 ↗
33. M. Tomaževič, Earthquake-Resistant Design of Masonry Buildings, 1999. doi: 10.1142/9781848160835.10.1142/9781848160835 ↗
34. Prestandard and, commentary for the seismic rehabilitation of buildings
35. Behavior of fully grouted reinforced concrete masonry shear walls failing in flexure: analysis10.1016/j.engstruct.2009.03.006 ↗