journal article·2019-04

Evaluation of post-cracking behavior of fiber reinforced concrete using indirect tension test

Leonardo Augusto Cruz Borges, Renata Monte, Dimas Alan Strauss Rambo, Antonio Domingues de Figueiredo

Publisher page

Abstract

Abstract This paper presents an experimental investigation on the applicability of the novel double-edge wedge splitting (DEWS) testing technique to evaluate the mechanical properties of fiber reinforced concretes (FRCs) with low fiber content. This study aims to validate the DEWS test for the structural evaluation of FRCs with softening behavior, which is also considered by the design codes for structural applications. In this case, the occurrence of post-peak instability is critical. This instability could compromise the residual strength evaluation, especially for the serviceability limit state (SLS). The experimental studies focused on three main aspects affecting the DEWS test response: effect of test displacement rate, effect of fiber content, and orthotropy of FRCs. Two different groups of FRCs (reinforced with steel and macrosynthetic fibers) were mechanically evaluated, both at the SLS and ultimate limit state. The variation of the test displacement rate had no significant impact on the FRC post-cracking pattern. The DEWS test could detect behavioral variations induced by altering the fiber content and fiber orientation on both composites. This variation was more evident for higher crack opening levels because the post-peak instability may compromise the DEWS results in the SLS.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Innovative concrete reinforcement materials · Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Final recommendation of RILEM TC 162-TDF: test and design methods for steel fibre reinforced concrete sigma-epsilon-design method10.1617/14007 ↗
2. Fibre-reinforced concrete in fib Model Code 2010: principles, models and test validation10.1002/suco.201300021 ↗
3. The Concrete Society (2013) Technical Report 34: Concrete industrial ground floors – a guide to their design and construction. 4th ed, Camberley.
4. Bentur · 1990
5. Proposed classification of FRC composites based on their tensile response10.1617/s11527-006-9103-2 ↗
6. European Committee for Standardization (2005) EN 14651 – Test method for metallic fibered concrete – Measuring the flexural tensile strength (limit of proportionality (LOP), residual). Brussels.
7. ASTM, Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading). ASTM Stand C1609/C1609M-12 1–9. doi: 10.1520/C1609, 2013.
8. Double Punch Test to control the energy dissipation in tension of FRC (Barcelona test)10.1617/s11527-008-9391-9 ↗
9. Derivation of a simplified stress–crack width law for Fiber Reinforced Concrete through a revised round panel test10.1016/j.cemconcomp.2015.01.005 ↗
10. Fiber reinforced concrete in the new fib Model Code
11. Fibre distribution and orientation of macro-synthetic polyolefin fibre reinforced concrete elements10.1016/j.conbuildmat.2016.06.083 ↗
12. Multidirectional double punch test to assess the post-cracking behaviour and fibre orientation of FRC10.1016/j.conbuildmat.2014.02.023 ↗
13. The WST method, a fracture mechanics test method for FRC10.1617/s11527-007-9231-3 ↗
14. Characterisation of the tensile constitutive behaviour of fibre-reinforced concrete: a new configuration for the Wedge Splitting Test10.1016/j.conbuildmat.2018.10.101 ↗
15. Double edge wedge splitting (DEWS): an indirect tension test to identify post-cracking behaviour of fibre reinforced cementitious composites10.1617/s11527-013-0028-2 ↗
16. Double-edge wedge splitting test: preliminary results
17. High toughness shotcrete for large deformation control at perseverance mine
18. Use of macro plastic fibres in concrete: a review10.1016/j.conbuildmat.2015.05.105 ↗
19. On the characterization of flexural toughness in fiber reinforced concretes10.1016/0958-9465(95)99506-O ↗
20. Mechanical characterization of synthetic macrofibres10.1590/1980-5373-MR-2015-0680 ↗
21. Fédération Internationale du Béton – FIB. Fib Model Code for Concrete Structures 2010. Switzerland, 2013, p. 402.
22. Intrinsic scatter of FRC: an alternative philosophy to estimate characteristic values10.1617/s11527-014-0420-6 ↗
23. Predicting pull-out behaviour based on the bond mechanism of arch-type steel fibre in cementitious composite10.1016/j.compstruct.2015.08.127 ↗
24. Pull-out behaviour of hooked steel fibres10.1007/BF02483148 ↗
25. Analysis of steel fibers pull-out. Experimental study10.1016/j.conbuildmat.2015.09.034 ↗
26. Fiber distribution and orientation in UHP-FRC beams and their effect on backward analysis
27. Post-cracking behaviour of steel and macro-synthetic fibre-reinforced concretes10.1016/j.conbuildmat.2010.12.022 ↗
28. Alferes Filho, R. S.Avaliação da influência do direcionamento de fibras de aço no comportamento mecânico de concreto autoadensável aplicado em elementos planos. 2016. 106p. Dissertação (Mestrado) - Escola Politécnica, Universidade de São Paulo, São Paulo, 2016.(In Portuguese).
29. Constitutive model for fibre reinforced concrete based on the Barcelona test10.1016/j.cemconcomp.2014.07.017 ↗