Performance of axially loaded masonry columns confined using textile reinforced concrete (TRC) added with short fibers
Source abstract
Abstract
Abstract Textile-reinforced high ductile concrete (TRHDC) (Li et al., 2020) is an optimized textile reinforced concrete (TRC) by using short polyvinyl alcohol (PVA) fibers. This work presented an experimental study on the compressive behavior of masonry piers confined with TRHDC jacket. The considered parameters were textile types, number of textile layers, together with a group of fiber reinforced polymer (FRP) confined columns as a reference set. Although the strength was greatly improved by the FRP wraps, the brittle failure and rather weak post-peak behavior were observed in the FRP strengthened columns. By contrast, TRHDC composites changed failure mode of columns with multiple thin cracks opening on the jacket. The compressive strength, ultimate strain and energy absorption capacity were improved by the TRHDC confinement. Analytical models from the literature were evaluated for their applicability to estimate the compressive strength of masonry piers confined with FRP or TRHDC jacket. Predictions were in good agreement with experimental data, which can be adopted in the engineering application.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Wound Healing and Treatments · Structural Analysis and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (51)
Show source-provided references
1. Masonry columns confined with glass textile-reinforced high ductile concrete (TRHDC) jacket10.1016/j.engstruct.2020.111123 ↗
2. High performance textile-reinforced concrete10.2749/101686699780481745 ↗
3. Experimental research on seismic behavior of reinforced concrete columns strengthened with TRC under corrosion environment10.1061/(ASCE)ST.1943-541X.0001713 ↗
4. Structural behaviour of fabric reinforced cementitious matrix (FRCM) strengthened concrete columns under eccentric loading10.1016/j.compositesb.2015.01.042 ↗
5. I.A. Yilmaz, P.E. Mezrea, et al., External confinement of brick masonry columns with open—grid basalt reinforced mortar. In: Proceedings of the Fourth Asia-Pacific conference on FRP in structures (APFIS 2013), Melbourne, Australia.
6. External jacketing of unreinforced historical masonry piers with open-grid basalt-reinforced mortar10.1061/(ASCE)CC.1943-5614.0000770 ↗
7. Flax and polyparaphenylene benzobisoxazole cementitious composites for the strengthening of masonry elements subjected to eccentric loading10.1016/j.compositesb.2014.10.055 ↗
8. Masonry columns strengthened with Steel Fabric Reinforced Cementitious Matrix (S-FRCM) jackets: Experimental and numerical analysis10.1016/j.measurement.2018.05.114 ↗
9. FRCM-confined masonry columns: experimental investigation on the effect of the inorganic matrix properties10.1016/j.conbuildmat.2018.08.020 ↗
10. Experimental investigation on the effect of mortar grade on the compressive behaviour of FRCM confined masonry columns10.1016/j.compositesb.2018.03.033 ↗
11. Experimental study on carbon fiber textile reinforced mortar system as a means for confinement of masonry columns10.1016/j.conbuildmat.2019.03.033 ↗
12. Compressive behavior of brick masonry columns confined with steel-reinforced grout jackets10.1061/(ASCE)CC.1943-5614.0000963 ↗
13. Effect of eccentricity on retrofitting efficiency of basalt textile reinforced concrete on partially damaged masonry columns10.1016/j.compstruct.2019.111585 ↗
14. Confinement of masonry columns with textile-reinforced mortar jackets10.1016/j.conbuildmat.2020.120343 ↗
15. Effect of corner over-reinforcing strips on the compressive behaviour of TRM confined masonry columns10.1617/s11527-020-01533-5 ↗
16. Masonry columns strengthened with FRCM system: Numerical and experimental evaluation10.1016/j.conbuildmat.2018.12.211 ↗
17. Experimental investigation on tensile behavior of carbon textile reinforced mortar (TRM) added with short polyvinyl alcohol (PVA) fibers10.1016/j.conbuildmat.2019.117801 ↗
18. Tensile behavior of glass textile reinforced mortar (TRM) added with short PVA fibers10.1016/j.conbuildmat.2020.119897 ↗
19. Tensile behavior of basalt textile grid reinforced engineering cementitious composite10.1016/j.compositesb.2018.08.059 ↗
20. Effect of short dispersed glass and carbon fibres on the behaviour of textile-reinforced concrete under tensile loading10.1016/j.engfracmech.2012.06.001 ↗
21. M. Hinzen, W. Brameshuber, Improvement of serviceability and strength of textile reinforced concrete by using short fibres. In: 4th Colloquium on textile reinforced structures, Dresden, Germany, 2009.
22. Cyclic loading tests of RC columns strengthened with high ductile fiber reinforced concrete jacket10.1016/j.conbuildmat.2017.07.175 ↗
23. Flexural behavior of reinforced concrete beams strengthened by HDC and RPC10.1016/j.conbuildmat.2018.08.124 ↗
24. GB/T 2542-2012. Test Methods for Wall Bricks. Beijing (CN); 2012.
25. JGJ/T 70-2009. Standard for Test Method of Basic Properties of Construction Mortar. Beijing (CN); 2009.
26. JC/T 2461-2018, Standard test method for the mechanical properties of ductile fiber reinforced cementitious composites. Beijing (CN); 2018.
27. Cyclic testing of unreinforced masonry walls retrofitted with engineered cementitious composites10.1016/j.conbuildmat.2018.05.132 ↗
28. Seismic response and shear mechanism of engineered cementitious composite (ECC) short columns10.1016/j.engstruct.2019.05.019 ↗
29. J. Hartig, F. Jesse, U. Häußler-Combe, Evaluation of experimental setups for determining the tensile strength of textile reinforced concrete, In: 2nd International RILEM Conference on Material Science, Aachen, Germany, 2010.
30. Testing procedures for the uniaxial tensile characterization of fabric-reinforced cementitious matrix composites10.1061/(ASCE)CC.1943-5614.0000626 ↗
31. Mechanical characterization of different FRCM systems for structural reinforcement10.1016/j.conbuildmat.2017.04.051 ↗
32. Mechanical properties of textile reinforced concrete plate at low textile ratios
33. GB/T 50129-2011. Standard for Test Method of Basic Mechanics Properties of Masonry. Beijing (CN): 2011.
34. Behavior of FRP strengthened concrete columns under eccentric compression loading10.1016/j.compstruct.2005.06.007 ↗
35. Effect of eccentric compression loading on the strains of FRCM confined concrete columns10.1016/j.conbuildmat.2014.03.007 ↗
36. Axial compressive behavior of grouted concrete block masonry columns confined by CFRP jackets10.1016/j.compositesb.2017.01.043 ↗
37. Discussion and definition on yield points of materials, members and structures
38. Reinforced concrete jacketing for masonry columns with axial loads
39. Structural performance of confined masonry walls retrofitted using ferrocement and GFRP under in-plane cyclic loading10.1016/j.engstruct.2015.03.035 ↗
40. State-of-the art review: Strengthening of reinforced concrete structures–different strengthening techniques
41. Analysis of flexural behavior of masonry column strengthened by wrapped steel outside under axial compression
42. Masonry confinement using steel cords10.1061/(ASCE)MT.1943-5533.0000753 ↗
43. Comparative experimental analysis on the compressive behaviour of masonry columns strengthened by FRP, BFRCM or steel wires10.1016/j.compositesb.2016.12.048 ↗
44. Analytical stress-strain law of FRP confined masonry in compression: Literature review and design provisions10.1016/j.compositesb.2016.10.019 ↗
45. Effectiveness of BFRP confinement on the compressive behaviour of clay brick masonry cylinders10.1016/j.compstruct.2020.112558 ↗
46. Structural upgrade using basalt fibres for concrete confinement10.1061/(ASCE)CC.1943-5614.0000114 ↗
47. CNR-DT 200 (R1 2013). Guide for the design and construction of externally bonded FRP systems for strengthening existing structures. Rome: Italian Council of Research (CNR); 2013.
48. Masonry confinement with fiber-reinforced polymers10.1061/(ASCE)1090-0268(2005)9:2(128) ↗
49. Strength and strain capacities of concrete compression members reinforced with FRP10.1016/S0958-9465(01)00048-8 ↗
50. Confinement of brick masonry columns with CFRP materials10.1016/j.compscitech.2006.11.002 ↗
51. Analysis-oriented model for concrete and masonry confined with fiber reinforced mortar10.1617/s11527-017-1072-0 ↗