journal article·2020-11

Corrosion of pipelines under dynamic direct current interference

Shan Qian, Y. Frank Cheng

Publisher page

Abstract

Abstract While pipeline corrosion under direct current (DC) interference has been investigated, there is few work conducted under dynamic DC existing in reality. This work studied corrosion of an X52 pipeline steel under dynamic DC interference in a diluted sodium bicarbonate solution, which simulated the soil electrolyte. Electrochemical measurements, weight-loss testing and surface characterization were used to determine the effects of DC current density, pulse frequency and wave form of the DC interference on the corrosion. It is found that the dynamic DC can accelerate the steel corrosion at a rate more rapidly than that under the static DC at specific current densities. However, the corrosion enhancement is not significant, especially at low DC current densities. The role of the AC component in the pulse DC in corrosion becomes more apparent as the DC current density increases. When the pulse frequency of the DC increases, the corrosion rate decreases. The wave form of the dynamic DC does not obviously affect the steel corrosion.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. The capacitive coupling between EHV lines and nearby pipelines10.1109/TPWRD.2003.823211 ↗
2. Mitigating AC corrosion on cathodically protected pipelines
3. Understand the AC induced pitting corrosion on pipelines in both high pH and neutral pH carbonate/bicarbonate solutions10.1016/j.corsci.2014.04.030 ↗
4. The corrosion behavior of steel exposed to a DC electric field in the simulated wet-dry cyclic environment10.1016/j.matchemphys.2017.01.057 ↗
5. Accelerated corrosion of pipeline steel and reduced cathodic protection effectiveness under direct current interference10.1016/j.conbuildmat.2017.05.024 ↗
6. R. Ellis, AC Induced Corrosion on Onshore Pipelines, A Case History, Shell UK, 2001.
7. P. Nicholson, High voltage direct current interference with underground/underwater pipelines, Corrosion 2010, paper no. 10102, NACE, Houston, TX, USA.
8. A review on stray current-induced steel corrosion in infrastructure10.1515/corrrev-2017-0009 ↗
9. Estimation of stray current from a DC-electrified railway and impressed potential on a buried pipe10.1109/TPWRD.2012.2211623 ↗
10. Feasibility of determining corrosion rates by means of stray current-induced polarisation10.1007/s10800-008-9591-6 ↗
11. Numerical simulation and experimental investigation of the stray current corrosion of viaducts in the high-speed rail transit system10.1016/j.conbuildmat.2017.09.114 ↗
12. Effects of vehicle running mode on rail potential and stray current in DC mass transit systems10.1109/TVT.2013.2265093 ↗
13. Electrochemical behavior of X70 steel corrosion in sand with direct current
14. Novel predictive model for metallic structure corrosion status in presence of stray current in DC mass transit systems10.1007/s11771-014-2024-2 ↗
15. Measuring and understanding the critical duration and amplitude of anodic transients10.1080/1478422X.2017.1386017 ↗
16. Visualising dynamic passivation and localised corrosion processes occurring on buried steel surfaces under the effect of anodic transients10.1016/j.elecom.2016.02.015 ↗
17. Localised corrosion of cathodically protected pipeline steel under the effects of cyclic potential transients10.1080/1478422X.2018.1471250 ↗
18. Investigation on corrosion rate and a novel corrosion criterion for gas pipelines affected by dynamic stray current10.1016/j.jngse.2015.06.044 ↗
19. The determination and identification of stray current source influences on buried pipelines using time/frequency analysis10.1108/00035590911000313 ↗
20. Evaluation and control of stray current in DC-electrified railway systems10.1109/TVT.2016.2555485 ↗
21. Development of a real-time AC/DC data acquisition technique for studies of AC corrosion of pipelines10.1016/j.corsci.2012.04.038 ↗
22. ASTM Standard practice for preparing, cleaning, and evaluating corrosion test specimens, ASTM International, 2011.
23. Synergism of imidazoline and sodium dodecylbenzenesulphonate inhibitors on corrosion inhibition of X52 carbon steel in CO2-saturated chloride solutions10.1016/j.molliq.2019.111674 ↗
24. Studies of water transport behavior and impedance models of epoxy-coated metals in NaCl solution by EIS10.1016/j.porgcoat.2004.08.001 ↗
25. Determination of effective capacitance and film thickness from constant-phase-element parameters10.1016/j.electacta.2009.10.065 ↗
26. Effect of alternating current on cathodic protection on pipelines10.1016/j.corsci.2012.09.028 ↗
27. Effects of corrosion product deposit on the subsequent cathodic and anodic reactions of X-70 steel in near-neutral pH solution10.1016/j.corsci.2008.08.026 ↗
28. The effects of bicarbonate on the corrosion and passivation of iron10.5006/0010-9312-36.8.416 ↗
29. Reactions of pipeline steels in carbon dioxide solutions10.1016/S0010-938X(98)00104-8 ↗
30. The corrosion of carbon steel in a chloride environment due to periodic voltage modulation10.1016/0010-938X(95)00066-S ↗
31. H. Song, Y. Kho, Y. Kim, S. Lee, Y.S. Park, Competition of AC and DC current in AC corrosion under cathodic protection, Corrosion 2002, NACE International, 2002.
32. The mechanism of alternating current corrosion of API grade X65 pipeline steel10.5006/2028 ↗
33. A periodic voltage modulation effect on the corrosion of Cu-Ni alloy10.1016/0010-938X(94)P4303-X ↗