Development and testing of precast concrete-filled square steel tube column-to-RC beam connections under cyclic loading
Source abstract
Abstract
Abstract Compared with the cast-in-place construction technique, the precast structure has advantages such as high industrialization, good quality, and environmental protection. Previous studies and investigations have shown that fabricated structures require secure connection technology, which could solve critical seismic problems associated with structures. The complex reinforcement layout in joint zone and the inefficient connection processes erode the economic value of the fabricated structure. This paper presents a novel precast concrete-filled square steel tube (CFSST) column-to-RC beam connection with energy dissipating (ED) bolts and prestressing tendons. In total, eight precast specimens with different axial compression ratios, ED bolt diameters, steel tube thicknesses, and beam end arrangement were tested under cyclic loading. The results show that the structural drift ratio obtained is up to 5.75%. The hysteresis curves of all specimens are plump. Even the specimen with the smallest diameter ED bolts can reach twice the energy dissipation capacity of the cast-in-place frame RC joint. The average ductility coefficients of all models are greater than 5. The precast CFSST column has good integrity and less damage after the earthquake. The final failure modes of the fabricated connections are governed by the plastic hinges at the beam. Besides, a calculation method for the flexural bearing capacity of the novel joint is developed and compared with the test results, which verified the feasibility of the model. The proposed precast connections exhibit superior resilience against earthquakes and can be used in active seismic regions.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Seismic Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Quantifying the waste reduction potential of using prefabrication in building construction in Hong Kong10.1016/j.wasman.2008.02.015 ↗
2. Investigation of precast RC beam-column assemblies under column-loss scenario10.1016/j.conbuildmat.2017.03.120 ↗
3. Experimental and numerical investigations of the seismic behavior of high-strength concrete beam-column joints with column axial load
4. Performance evaluation of semi precast concrete Beam-column connections with U-shaped strands10.1260/1369-4332.17.11.1585 ↗
5. Seismic tests of beam-to-column connections in a precast concrete frame10.15554/pcij.05012002.70.89 ↗
6. Experimental study of a new beam-to-column connection for precast concrete frames under reversal cyclic loading10.1177/1369433216630122 ↗
7. Ductile connections in precast concrete moment resisting frames10.15554/pcij.05012006.66.76 ↗
8. Quasi-static test and strut-and-tie modeling of precast concrete shear walls with grouted lap-spliced connections10.1016/j.conbuildmat.2017.05.183 ↗
9. Seismic analysis of precast concrete bridge columns connected with grouted splice sleeve connectors10.1061/(ASCE)ST.1943-541X.0001678 ↗
10. Studies on seismic performance of precast concrete columns with grouted splice sleeve10.3390/app7060571 ↗
11. Seismic repair of severely damaged precast reinforced concrete bridge columns connected with grouted splice sleeves10.14359/51688756 ↗
12. Overview of PRESSS research program10.15554/pcij.07011991.50.57 ↗
13. PRESSS program-current status and proposed plans for phase III10.15554/pcij.03011996.22.40 ↗
14. J.F. Stanton, S.D. Nakaki. Design guidelines for precast concrete seismic structural systems. PRESSS report. Seattle: Department of Civil Engineering, University of Washington, 2002.10.15554/pci.rr.seis-011 ↗
15. Seismic response of precast prestressed concrete frames with partially debonded tendons10.15554/pcij.01011993.58.69 ↗
16. Seismic response of precast concrete frames with hybrid connections
17. Performance of hybrid moment-resisting precast beam-column concrete connections subjected to cyclic loading
18. A friction damper for post-tensioned precast concrete beam-to-column joints10.15554/pcij.07012004.112.133 ↗
19. High-force-to-volume seismic dissipators embedded in a jointed precast concrete frame10.1061/(ASCE)ST.1943-541X.0000329 ↗
20. Performance of a damage-protected beam-column subassembly utilizing external HF2V energy dissipation devices10.1002/eqe.830 ↗
21. P.K. Aninthaneni, R.P. Dhakal, J. Marshall. Nonlinear Cyclic Behaviour of Precast Concrete Frame Sub-Assemblies With “Dry” End Plate Connection. Structures. 2018124-36.
22. Analytical and numerical investigation of “dry” jointed precast concrete frame sub-assemblies with steel angle and tube connections10.1007/s10518-019-00663-8 ↗
23. S.F. Li, Q.L. Li, H. Zhang, H.T. Jiang, L. Yan, Jiang WS. Experimental study of a fabricated confined concrete beam to-column connection with end-plates. Constr. Build. Mater. 2018208-16.
24. Experimental study of a novel precast prestressed reinforced concrete beam-to-column joint10.1016/j.engstruct.2017.11.011 ↗
25. Investigation of precast RC beam-column assemblies under column-loss scenario10.1016/j.conbuildmat.2017.03.120 ↗
26. Experimental behavior and failure modes of hybrid beam-to-column connections with RC wing-walls in industrial construction10.1016/j.conbuildmat.2019.05.154 ↗
27. Mixed finite-element modeling of rectangular concrete-filled steel tube members and frames under static and dynamic loads10.1061/(ASCE)ST.1943-541X.0000158 ↗
28. Experimental behavior of connections to concrete- filled steel tubes10.1016/S0143-974X(97)00071-0 ↗
29. Experimental behaviour of thin-walled steel tube confined concrete column to RC beam joints under cyclic loading10.1016/j.tws.2009.03.001 ↗
30. Axial compressive behavior of through-beam connections between concrete-filled steel tubular columns and reinforced concrete beams10.1061/(ASCE)ST.1943-541X.0001249 ↗
31. Q.J. Chen, J. Cai, M. Bradford, X.P.Liu, Z.L. Zao. Seismic behaviour of a through-beam connection between concrete-filled steel tubular columns and reinforced concrete beams. Eng. Struct. 201424-39.
32. CBIP H. Code for design of concrete structures. In: CBIP H, editor. GB50010-2010. Beijing: China: Architecture and Building Press, 2010.
33. ACI. ACI 550.1R-09: guide to emulating cast-inplace detailing seismic design of precast concrete structures. In: Institute AC, editor. MI, USA: Detroit, 2009.
34. Element mesh, section discretization and material hysteretic laws for fiber beam-column elements of composite structural members10.1617/s11527-014-0335-2 ↗
35. Acceptance Criteria for Moment Frames Based on Structural Testing and Commentary. In: ACI, editor. ACI 374.1-05. Farmington Hills: MI: American Concrete Institute, 2005.
36. Zhou · 1991
37. Models for behaviour analysis of monolithic wall and precast or monolithic floor slab connections10.1016/j.engstruct.2012.03.007 ↗
38. ASCE. Seismic Rehabilitation of Existing Buildings (ASCE/SEI 41-06). Reston, VA2007.
39. CBIP H. Specification of Testing Methods for Earthquake Resistant Building. In: CBIP H, editor. JGJ/T101-2015. Beijing, China: China Architecture and Building Press, 2015.
40. Chopra · 2012
41. Theoretical stress-strain model or for confined concrete10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
42. Experimental study on a precast beam-column joint with double grouted splice sleeves10.1016/j.engstruct.2019.109589 ↗
43. Experimental study on flexural behaviour of inorganic polymer concrete beams reinforced with basalt rebar10.1016/j.compositesb.2016.03.021 ↗
44. Can precast concrete structures be designed as semi-rigid frames? Part 2 - Analytical equations & column effective length factors
45. Inelastic design of reinforced concrete beams and limited ductilehigh-strength concrete columns