journal article·2013-04Open access

Examining the possibility to estimate the influence of admixtures on pore structure of self-compacting concrete using the air void analyzer

Beata Łaźniewska-Piekarczyk

Abstract

The relationships between pressure methods of measuring air content in fresh concrete and measurements of air-void system parameters using the Air Void Analyzer (AVA) for fresh self-compacting concrete (SCC) and high performance self-compacting concrete (HPSCC) made with two different superplasticizer (SP) type, air-entraining admixture (AEA), viscosity modifying admixture (VMA) and anti-foaming admixture (AFA) is examined in the paper. The air content, size distribution, specific surface, and spacing factor of concrete mixtures were tested. The results indicated that the admixtures significantly affect the porosity of SCC and HPSCC. The correlation between the AVA tests and the porosity of hardened SCC and HPSCC tests (EN 480-11) was investigated also. The research results showed that fluidity of fresh concrete mixture significantly affect the reliability of the measurement using AVA.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete and Cement Materials Research · Innovations in Concrete and Construction Materials · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. ACI 201.2R-01. Guide to durable concrete. ACI manual of concrete practice. Farmington Hills (MI): American Concrete Institute; 2001.
2. Crawford GL, Wathne LG, Mullarky JI. A “fresh” perspective on measuring air in concrete. 2003 Concrete Bridge Conference.
3. Kosmatka · 2002
4. The influence of selected new generation admixtures on the workability, air-voids parameters and frost-resistance of self compacting concrete10.1016/j.conbuildmat.2011.12.107 ↗
5. Air-void stability in self-consolidating concrete
6. Optimization and performance of the air-entrained self-consolidating concrete
7. Air entrainment in the presence of superplasticizers
8. The influence of water-reducers on the production and stability of the air void system in concrete10.1016/0008-8846(89)90014-8 ↗
9. Laboratory investigation of rheological properties and scaling resistance of air entrained self-consolidating concrete10.1007/BF02481521 ↗
10. Mechanisms of air entrainment in concrete10.1016/j.cemconres.2004.07.026 ↗
11. Air-entrained self-consolidating concrete: a study of admixture sources10.1016/j.conbuildmat.2011.06.049 ↗
12. Self-consolidating concrete incorporating new viscosity modifying admixtures10.1016/j.cemconres.2003.10.024 ↗
13. Zhang S, Wang K. Effects of materials and mixing procedures on air void characteristics of fresh concrete. In: Proceedings of the 2005 mid-continent transportation research symposium, Ames, Iowa, August 2005.
14. The requirements for porosity parameters of frost-resistance self-compacting concrete (SCC)
15. Rheology and early age properties of cement systems10.1016/j.cemconres.2007.09.006 ↗
16. The influence of anti-foaming admixtures on properties self-compacting mix and concrete
17. Hansen W. Quantitative and rapid measurement of air-void system in fresh concrete. Report SHRP-ID-URF-91-519. Washington (DC): Transportation Research Board, National Research Council; 1991.
18. Wang K, Mohamed-Metwally M, Bektas F, Grove J. Improving variability and precision of air-void analyzer (AVA) test results and developing rational specification limits. Center for Transportation Research and Education, Iowa State University, Phase 1 Report, June 2008. 97 p.
19. Comparison of the air contents of freshly mixed and hardened concretes cement10.1520/CCA10543J ↗
20. Comparison of air contents in fresh and hardened concretes using different airmeters10.1520/CCA10545J ↗
21. The increase of air-content in mix under influence of carboxylate superplasticizers acting
22. EN 12350-8:2010, Testing fresh concrete – Part 8: Self-compacting concrete – slump-flow test.
23. EN 12350-7:2009, Testing fresh concrete. Air content. Pressure methods.
24. The air void anlayzer manual instruction by GERMANN INSTRUMENTS.
25. EN 480-11:2008, Admixtures for concrete, mortar and grout – test methods – Part 11: Determination of air void characteristics in hardened concrete.
26. Air void system and frost-salt scaling of concrete containing slag-blended cement10.1016/j.conbuildmat.2008.10.001 ↗
27. Influence of superplasticizers on the hydration of cement and the pore structure of hardened cement10.1016/j.cemconres.2006.08.003 ↗
28. Influence of superplasticizer and curing on porosity and pore structure of cement paste10.1016/S0958-9465(99)00031-1 ↗
29. The effect of superplasticizers on the entrained air-void system in concrete10.1016/0008-8846(86)90110-9 ↗
30. Gay FT. A factor which may affect differences in the determined air content of plastic and hardened air-entrained concrete. In: Proceedings of the fourth international conference on cement microscopy. Las Vegas: Int. Cem. Microscopy Assoc.; 1982. p. 286−92.
31. Jana D. Around robin test on measurements of air void parameters in hardened concrete by various automated image analyses and ASTM C 457 methods. In: Proceedings of the twenty-ninth conference on cement microscopy Quebec City, Pq, Canada May 20–24, 2007.
32. Wang K, Lomboy G, Steffes R. Investigation into freezing–thawing durability of low-permeability concrete with and without air entraining agent. National Concrete Pavement Technology Center, Final Report, June 2009.
33. Pinto · 2001
34. Taylor P. Presentation at the project TAC meeting at ISU, Ames, IA, 2007.
35. Magura DD. Air void analyzer. Evaluation. May 1996. FHWA-SA-96-062.
36. Pade C, Jakobsen UH, Elsen J. A new automatic analysis system for analyzing the air void system in hardened concrete. International cement microscopy association conference, San Diego (CA), USA, April 2002.
37. Taylor PC, Johansen VC, Graf LA, Kozikowski Ronald L, Zemajtis Jerzy Z, Ferraris Chiara F. Identifying incompatible combinations of concrete materials, vol. I – Final, Report, FHWA-HRT-06-079, August 2006.
38. ASTM C 457-98. Standard test method for determining parameters of air-void system in hardened concrete. West Conshohocken (PA): Annual Book of ASTM Standards, ASTM; 2003.
39. Summary Report of Task 2: BRITE/EURAM Project No: BE-3376-89, Qualitative and quantitative determination of the air void structure of fresh concrete, Dansk Beton Teknik A/S, February, 1994.
40. Magura DD. Air void analyzer evaluation. FHWA-SA-96-062; Federal Highway Administration, 1996.
41. Trost S. Measuring air void characteristics of oklahoma air-entrained concrete using the Air Void Analyzer (AVA)/analyzing AVA sources of error. Final Report – FHWA-OK-08-03 ODOT Spr Item Number 2182, January 2009.
42. ACI 211.1R-91. Standard practice for selecting proportions for normal, heavyweight, and mass concrete. ACI manual of concrete practice. Farmington Hills (MI): American Concrete Institute; 1991.
43. Wojakowski J, Real air testing in real time. [accessed in 2012].