journal article·2019-07

Behaviour of concrete filled glass fibre-reinforced polymer tubes under static and flexural fatigue loading

Farhad Aslani, Yasoja Gunawardena, Ayoub Dehghani

Publisher page

Abstract

Abstract Concrete-filled glass fibre-reinforced polymer tubes (CFFTs) have reportedly been considered for industrial applications such as fender piling for marine structures and bridge girders. Even though previous investigations of the flexural fatigue behaviour of circular sectioned CFFTs have been reported in the literature, no such study has been carried out for square or rectangular sectioned tubes. In order to address this research gap, an experimental programme was carried out to investigate the flexural fatigue behaviour of square sectioned CFFTs, considering fatigue deformation cycles equal to 75%, 80%, 85% and 90% of the deformation corresponding to the static flexural failure of the tested CFFTs. The used glass fibre-reinforced polymer (GFRP) tubes contained reinforcements at the longitudinal direction and ±45° to the longitudinal axis of tubes. They were also specified to have much larger longitudinal tensile and compressive strength compared to typical rectangular GFRP tubes. Self-compacting concrete was used for the core-infill of the tested CFFTs. In total, eight static flexural tests and sixteen flexural fatigue tests were conducted under displacement-control fatigue loading using two loading arrangements, namely three-point and four-point bending. All CFFTs beams subjected to the fatigue loading failed due to buckling of the compression flange of CFFT. It was observed that the number of cycles to failure for the employed fatigue deformation ranges were quite low and decreased with increasing the amplitude of fatigue deformation. The bending stiffness of the tested specimens was observed to decrease as the fatigue loading progressed. It was also found that the amount of dissipated energy in a given cycle and the rate of stiffness degradation increases with an increase in the amplitude of fatigue deformation, especially for specimens tested under four-point bending. Furthermore, the bending stiffness at failure for the specimens tested under four-point bending was found to be approximately 80–90% of its initial value.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Characterization of GFRP pultruded box beams under static and fatigue loads
2. Fatigue behavior of RC beams strengthened with GFRP sheets10.1061/(ASCE)1090-0268(2001)5:4(246) ↗
3. Fatigue behavior of externally strengthened concrete beams with fiber-reinforced polymers: state of the art10.1061/(ASCE)1090-0268(2008)12:3(246) ↗
4. Fatigue of concrete beams strengthened with glass-fiber composite under flexure10.1061/(ASCE)CC.1943-5614.0000189 ↗
5. Hollaway · 2008
6. State-of-the-art review on FRP strengthened steel structures10.1016/j.engstruct.2006.10.006 ↗
7. Bai · 2013
8. Barbero · 1999
9. Civil and structural engineering applications, recent trends, research and developments on pultruded fiber reinforced polymer closed sections: a review10.1007/s11709-013-0216-8 ↗
10. Advanced composite bridge decking system—project ASSET10.2749/101686602777965522 ↗
11. Stay-in-place FRP form for concrete columns10.1260/136943303322419241 ↗
12. Echevarria · 2014 · 441
13. Tests on reinforced-concrete-filled, fiber-reinforced-polymer circular tubes of different shear spans10.1139/l06-104 ↗
14. Fatigue behavior of concrete-filled fiber-reinforced polymer tubes10.1061/(ASCE)1090-0268(2008)12:4(478) ↗
15. Developments and advanced applications of concrete-filled steel tubular (CFST) structures: members10.1016/j.jcsr.2014.04.016 ↗
16. Flexural behavior of rectangular FRP-tubes filled with reinforced concrete: experimental and theoretical studies10.1016/j.engstruct.2016.12.010 ↗
17. Composite action of concrete-filled rectangular GFRP tubes10.1061/(ASCE)CC.1943-5614.0000370 ↗
18. Investigation of flexural behaviors of hybrid beams formed with GFRP box section and concrete10.1016/j.conbuildmat.2012.12.060 ↗
19. Prestressed concrete-filled fiber-reinforced polymer circular tubes tested in flexure10.15554/pcij.07012006.42.54 ↗
20. Rectangular filament-wound glass fiber reinforced polymer tubes filled with concrete under flexural and axial loading: experimental investigation10.1061/(ASCE)1090-0268(2005)9:1(25) ↗
21. Flexural behavior of concrete-filled fiber-reinforced polymer circular tubes10.1061/(ASCE)1090-0268(2002)6:2(123) ↗
22. Lawrence · 2014
23. Experimental investigation on the behaviour of concrete-filled FRP tubes under flexural load
24. Influence of infill concrete strength on the flexural behaviour of pultruded GFRP square beams10.1016/j.compstruct.2016.02.071 ↗
25. Flexural strength and behavior of steel and FRP-reinforced concrete-filled FRP tube beams10.1016/j.engstruct.2010.08.023 ↗
26. Flexural behavior of GFRP tubes filled with magnetically driven concrete10.3390/ma11010092 ↗
27. Composite tubes as an alternative to steel spirals for concrete members in bending and shear10.1016/j.conbuildmat.2005.08.016 ↗
28. Flexural behaviour of multi-celled GFRP composite beams with concrete infill: experiment and theoretical analysis10.1016/j.compstruct.2016.09.049 ↗
29. Beam-column behavior of steel tubes filled with high strength concrete10.1139/l94-024 ↗
30. Fatigue life assessment and static testing of structural GFRP tubes based on coupon tests10.1061/(ASCE)1090-0268(2008)12:2(212) ↗
31. Experimental investigation of cyclic behavior of concrete-filled fiber reinforced polymer tubes10.1061/(ASCE)1090-0268(2005)9:3(263) ↗
32. Effects of driving forces and bending fatigue on structural performance of a novel concrete-filled fibre-reinforced-polymer tube flexural pile10.1139/l05-075 ↗
33. An empirical model for fatigue behavior prediction of glass fibre-reinforced plastic composites for various stress ratios and test frequencies10.1016/S1359-835X(03)00052-6 ↗
34. Wagners · 2014
35. Behaviour of hollow and SCC filled high-strength GFRP tubes under concentric and eccentric compression
36. American Society of Testing Materials, ASTM D638-02a Standard test method for tensile properties of plastics, 2003.
37. Standards Australia, AS 1012.9:2014 Method of testing concrete Method 9: Compressive strength tests - Concrete, mortar and grout specimens, 2014.