Shear behavior of single- and triple-thickness masonry panels strengthened by bed-joint structural repointing
Source abstract
Abstract
Abstract Bed-joint structural repointing is a widely used strengthening technique in historic masonry constructions, particularly in applications where the material appearance needs to be preserved. Despite its wide use, limited research is available on the effectiveness of this technique in masonry elements of greater thickness subjected to in-plane shear loading. In the reported study, the shear behavior of single- and triple-thickness masonry panels strengthened with Near Surface Mounted (NSM) steel bars was investigated. Masonry panels were built following the material characteristics and bonding types of a reference case and tested in diagonal compression. Two lime-based mortar mixes with different compressive strength were employed to assess the effect of existing mortar quality on the strengthening technique performance. The investigated parameters were the number of courses with reinforcement in single-thickness panels, and the depth of the reinforcement and number of the faces reinforced in those of triple-thickness. The technique proved effective in improving the shear deformation capacity regardless of specimen thickness and, in panels of triple-thickness, both the eccentricity (result of reinforcing one or two faces) and depth of reinforcement were observed to significantly affect shear behavior.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Behavior of Reinforced Concrete · Building materials and conservation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. D. D’Ayala, G. Benzoni, Historic and traditional structures during the 2010 Chile earthquake: observations, codes, and conservation strategies, Earthq. Spectra. 28 (2012) 425–451.10.1193/1.4000030 ↗
2. A. Penna, P. Morandi, M. Rota, C. Manzini, F. da Porto, G. Magenes, Performance of masonry buildings during the Emilia 2012 earthquake, Bull. Earthq. Eng. 12 (2014) 2255–2273.10.1007/s10518-013-9496-6 ↗
3. Damage assessment of unreinforced stone masonry buildings after the 2010–2011 Canterbury earthquakes10.1080/15583058.2013.840688 ↗
4. G. Brando, D. Rapone, E. Spacone, M.S. O’Banion, M.J. Olsen, A.R. Barbosa, M. Fagella, R. Gigliotti, D. Liberatore, S. Russo, L. Sorrentino, S. Bose, A. Stavridis, Damage reconnaissance of unreinforced masonry bearing wall buildings after the 2015 Gorkha, Nepal, earthquake, Earthq. Spectra. 33 (2017) S243–S273.10.1193/010817eqs009m ↗
5. Damages observed in locations of Oaxaca due to the Tehuantepec Mw8.2 earthquake, Mexico10.1007/s11069-019-03662-9 ↗
6. Seismic damage and fragility assessment of ancient masonry churches located in central Chile10.1007/s10518-020-00831-1 ↗
7. Fiber reinforced polymer strengthening of structures by near-surface mounting method10.3390/polym8080298 ↗
8. Shear strengthening of masonry wallettes resorting to structural repointing and FRCM composites10.1016/j.conbuildmat.2019.02.044 ↗
9. Mechanical behaviour of historic masonry structures strengthened by bed joints structural repointing10.1016/j.conbuildmat.2004.04.036 ↗
10. In-plane shear behaviour of masonry wall panels strengthened by structural repointing
11. J.G. Tumialan, A. Morbin, A. Nanni, C. Modena, Shear Strengthening of Masonry Walls with FRP Composites, en: Compos. 2001, Conv. Trade Show, Compos. Fabr. Assoc., Tampa, FL, 2001.10.1061/40558(2001)130 ↗
12. Analysis of unreinforced masonry concrete walls strengthened with glass fiber-reinforced polymer bars
13. Flexural and shear strengthening of un-reinforced masonry with FRP bars10.1016/j.compscitech.2005.04.042 ↗
14. Diagonal shear behaviour of unreinforced masonry wallettes strengthened using twisted steel bars10.1016/j.conbuildmat.2011.04.063 ↗
15. In-plane performance of unreinforced concrete masonry strengthened with prestressed GFRP bars10.1061/(ASCE)CC.1943-5614.0000717 ↗
16. Diagonal compression testing of FRP-retrofitted unreinforced clay brick masonry wallettes10.1061/(ASCE)CC.1943-5614.0000209 ↗
17. Experimental and applied element modeling of masonry walls retrofitted with near surface mounted (NSM) reinforcing steel bars10.1007/s10518-019-00607-2 ↗
18. Numerical assessment of accumulated seismic damage in a historic masonry building. A case study
19. Multi directional pushover analysis of irregular masonry buildings without box behavior10.1016/j.engstruct.2019.109534 ↗
20. R. Valledor, D. López-García, C. Sandoval, Linearly elastic seismic evaluation of masonry historical buildings in Santiago, Chile: The case of the Pereira Palace, en: V.C. Cardiel (Ed.), 3rd Int. Conf. Mech. Model. Struct. Eng. C. 2015, Sevilla, España, 2015: pp. 281–299.
21. I. Ioannou, M. Philokyprou, A. Ilia, Design and Production of Repair Mortars for Historic Masonry Taking into Account the Characteristics of Old Mortars, en: J. Válek, C.J.W.P. Groot, J.J. Hughes (Eds.), 2nd Conf. Hist. Mortars - HMC 2010 RILEM TC 203-RHM Final Work., RILEM Publications SARL, 2010: pp. 1051–1058.
22. INN, Norma Chilena Oficial NCh167.Of2001. Construcción - Ladrillos cerámicos - Ensayos, (2001).
23. ASTM, C67. Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile., ASTM Int. (2019).
24. RILEM TC 127 MS D.7., Determination of pointing hardness by pendulum hammer, en: Mater. Struct., 1997: pp. 323–328.10.1007/BF02480682 ↗
25. Assessment of Mortar and Brick Strength in Earthquake-Affected Structures in Peru Using a Schmidt Hammer10.1061/(ASCE)CF.1943-5509.0000120 ↗
26. RILEM TC 203-RHM, The Role of Mortar in Masonry : an Introduction to Requirements for the Design of Repair Mortars, en: J. Válek, C.J.W.P. Groot, J.J. Hughes (Eds.), 2nd Conf. Hist. Mortars - HMC 2010 RILEM TC 203-RHM Final Work., RILEM Publications SARL, 2010: pp. 1323–1329.
27. B. Middendorf, J.J. Hughes, K. Callebaut, G. Baronio, I. Papayianni, Mineralogical characterization of historic mortars, en: C.J.W.P. Groot, G.J. Ashall, J.J. Hughes (Eds.), Characterisation old mortars with respect to their repair—final Rep. RILEM TC 167–COM, RILEM Publications SARL, 2004: pp. 23–38. https://doi.org/10.1617/2912143675.003.10.1617/2912143675.003 ↗
28. Characterization of historical mortars from Santa Catarina (Brazil)10.1016/j.cemconcomp.2009.02.013 ↗
29. INN, Norma Chilena Oficial NCh158.Of67. Cementos – Ensayo de flexión y compresión de morteros de cemento, (1999).
30. CEN, EN 998-2: Specification for mortar for masonry – Part 2: Masonry Mortar, (2010).
31. ASTM, C1437. Standard Test Method for Flow of Hydraulic Cement Mortar, (2013) 1–2. https://doi.org/10.1520/C1437-13.2.
32. ASTM, A615/A615M-03a. Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement, (2016).
33. INN, Norma Chilena Oficial NCh200.Of72. Productos metálicos - Ensayo de tracción, (1999).
34. J. Gonzalez-Libreros, T. D’Antino, F. Focacci, C. Carloni, C. Pellegrino, Structural repointing of masonry structures, en: Key Eng. Mater., 2019. https://doi.org/10.4028/www.scientific.net/KEM.817.412.10.4028/www.scientific.net/KEM.817.412 ↗
35. INN, Norma Chilena Oficial NCh2123.Of97. Albañilería confinada - Requisitos de diseño y cálculo, (2003).
36. ASTM, E519-2010. Standard test method for diagonal tension (shear) in masonry assemblages. American Society for Testing Material, (2010).