journal article·2012-05

Short-term performance of the HSB® shear plate-type connector for timber–concrete composite beams

Jose L. Fernandez-Cabo, Francisco Arriaga, Almudena Majano-Majano, Guillermo Iñiguez-González

Publisher page

Abstract

Abstract Experimental results of eight short-term tests of the HSB® (Habitat System Beton) timber–concrete connection system are presented. The specimens were compressive double shear tested according to EN 26891:1991, placing two connectors per shear plane. The ultimate shear force and slip modulus were measured and compared with the estimated values proposed by structural European design codes. The comparison between experimental and code values presents unsafe results for stiffness and the recommended distance between connectors, but results are consistent for strength. The connector itself failed in almost 50% of the cases due to the brittleness of the aluminium alloy.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Civil and Structural Engineering Research · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Timber–concrete composite structures
2. Lukaszewska E. Development of prefabricated timber–concrete composite floors. Doctoral thesis. Luleå University of Technology. Universitetstryckeriet, Luleå; 2009.
3. Wood–concrete and wood–wood mixed beams: rational basis for selecting connections10.1061/(ASCE)0733-9445(2008)134:3(440) ↗
4. EN 1995-1-1:2004. Eurocode 5. Design of timber structures. Part 1-1: General. Common rules and rules for buildings.
5. Meierhofer UA. RF 2000, a new efficient system for timber/concrete composite structural elements. Test, research and development. In: Proc for the IUFRO S5.02 timber engineering conference; 1992. p. 383–93.
6. Timmermann K, Meierhofer UA. Holz-Beton-Verbundkonstruktionen, Untersuchungen und Entwicklungen zum mechanischen Verbund von Holz und Beton. Forschungsbericht 115/30. Abteilung Holz: EMPA; 1993.
7. Experimental study of a composite wood–concrete beam with the INSA-Hilti new flexible shear connector10.1016/S0950-0618(99)00034-3 ↗
8. Short- and long-term performance of the “Tecnaria” stud connector for timber–concrete composite beams10.1617/s11527-006-9200-2 ↗
9. Bathon LA, Graf M. A continuous wood–concrete–composite system. In: Proc, world conference on timber engineering. Whistler Resort, British Columbia, Canada, CD; 2000.
10. Experimental behaviour of a continuous metal connector for a wood–concrete composite system
11. Natterer J, Hamm J, Favre P. Composite wood–concrete floors for multi-story buildings. In: Proc international wood engineering conference, New Orleans, Louisiana, vol. 3; 1996. p. 431–5.
12. Natterer J. Concepts and details of mixed timber–concrete structures. In: International Association for Bridge and Structural Engineering (IABSE) composite construction conference. Innsbruck, Austria; 1997. p. 175–80.
13. Kuhlmann U, Schänzlin J. Grooves as shear connectors for timber–concrete composite decks. In: Proc international RILEM symposium: joints in timber structures. Stuttgart, Germany; 2001. p. 283–90.
14. Kuhlmann U, Michelfelder B. Grooves as shear-connectors in timber–concrete composite structures. In: Proc 8th world conference on timber engineering WCTE 2004, Lahti, Finland, vol. 1; 2004. p. 301–6.
15. Michelfelder, Birgit C. Trag- und verformungsverhalten von kerven bei brettstapel-beton-verbunddecken. Doctoral thesis, Stuttgart, Institut für Konstruktion und Entwurf; 2006.
16. Laboratory tests of composite wood-concrete beams10.1016/j.conbuildmat.2007.03.013 ↗
17. Effects of various admixtures and shear keys in wood–concrete composite beams10.1016/j.conbuildmat.2010.02.016 ↗
18. Connections for composite concrete slab and LVL flooring systems10.1617/s11527-007-9261-x ↗
19. A semi-prefabricated LVL-concrete composite floor system for the Australasian market10.1080/13287982.2009.11465025 ↗
20. Performance of connections for prefabricated timber–concrete composite floors10.1617/s11527-007-9346-6 ↗
21. Toratti T, Kevarinmäki A. Development of wood-concrete composite floors. Reports of the working commissions, Zurich, Weitzerland, International Association for Bridge and Structural Engineering (IABSE), 2001, p. 513–8.10.2749/222137801796349132 ↗
22. EN 1194:1999. Timber structures. Glued laminated timber. Strength classes and determination of characteristic values.
23. RC-08:2008. Instrucción para la recepción de cementos. Real Decreto 956/2008 de 6 de junio. Gobierno de España.
24. EN 206-1:2000/A2 2005. Concrete. Part 1: Specification, performance, production and conformity.
25. EN 12390-3:2009 Testing hardened concrete. Compressive strength of test specimens.
26. EN 10080:2005. Steel for the reinforcements of concrete. Weldable reinforcing steel. General.
27. EN 1706:1998. Aluminium and aluminium alloys. Casting. Chemical composition and mechanical properties.
28. EN 912: 1999 AC. Timber fasterners. Specifications for connector for timber.
29. EN 26891:1991. Timber structures. Joints made with mechanical fasteners. General principles for the determination of strength and deformation characteristics.
30. Theoretical and experimental analysis of timber-to-timber joints connected with inclined screws10.1016/j.conbuildmat.2010.03.007 ↗
31. Monteiro S, Dias A, Negrão J. Experimental and numerical evaluation of notched timber–concrete joints mechanical behaviour. In: Proceedings of 11th WCTE, Italy; 2010.
32. Dias A, Cruz H, Lopes S, Van de Kuilen JWG. Experimental shear-friction tests on dowel type Fastener timber–concrete Joints. In: Proceedings of 8th WCTE Finland; 2004.
33. ARAMIS® system, GOM mbH, Mittelweg 7–8, 38106 Braunschweig, Germany. .
34. Ring and shear plate connector joints