journal article·2023-01

Diagonal compression cyclic testing of unreinforced and reinforced masonry walls

Luigi Biolzi, Sara Cattaneo, Pietro Crespi, Manuela Scamardo, Navid Vafa

Publisher page

Abstract

Steel reinforced plasters (SRP) are a traditional strengthening solution of existing masonry structures. SRPs consist of a thin layer of cementitious mortar or concrete (jacket) that incorporates a steel reinforcing mesh tied to a series of steel bent connectors embedded in the underlying masonry. Despite the recent development of more innovative retrofitting methods, SRPs are still widely adopted because of their low costs and effectiveness in terms of improved performance. In the present paper, a comprehensive experimental program on brickwork masonry walls is presented. The results are intended as a contribution to the knowledge of in-plane behavior of masonry strengthened with SRPs. Unreinforced and plastered masonry walls were subjected to cyclic diagonal compression loading under displacement control. Different thicknesses of walls (2 and 3 wythes) and plasters (30 and 50 mm) were selected. The performances of the plastered and non-plastered specimens were analyzed and compared. The results showed that the SRPs increased considerably the performance of the walls in terms of both strength and deformation capacity. The plaster's thickness had limited effects on the load carrying capacity of the walls, whereas it had a significant effect on their ductility. Finally, the connectors used to tie the steel mesh to the masonry walls played an essential role and avoided large out-of-plane displacements of the plaster layer after its detachment, thus preventing instability phenomena.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (60)

Show source-provided references
1. Damage and performance evaluation of masonry churches in the 2009 l’aquila earthquake10.1016/j.engfailanal.2013.01.021 ↗
2. Damage assessment of three medieval churches after the emilia earthquake
3. Seismic vulnerability assessment and earthquake response of slender historical masonry bell towers in south-east lombardia10.1016/j.engfailanal.2021.105656 ↗
4. Evaluation of strengthening techniques of traditional masonry buildings: case study of a four-building aggregate10.1061/(ASCE)CF.1943-5509.0000164 ↗
5. The new foundation system of the basilica di collemaggio’s transept10.1504/IJMRI.2020.104846 ↗
6. Seismic vulnerability assessment and consolidation techniques of ancient masonry buildings: the case study of a neapolitan masseria10.1016/j.engfailanal.2022.106306 ↗
7. Numerical approaches for cross-laminated timber roof structure optimization in seismic retrofitting of a historical masonry church10.1007/s10518-019-00661-w ↗
8. Elgawady, M.A.; Lestuzzi, P. A Review of Conventional Seismic Retrofitting Techniques for URM. 13th International Brick and Block Masonry Conference 2004, 1–10.
9. A critical review of retrofitting methods for unreinforced masonry structures10.1016/j.ijdrr.2013.12.004 ↗
10. Ungureanu, D.; Nicolae, Tă.; Ghiga, D.A.; Isopescu, D.N.; Mihai, P.; Cozmanciuc, R. Diagonal Tensile Test on Masonry Panels Strengthened with Textile-Reinforced Mortar. 2021, doi:10.3390/ma14227021.10.3390/ma14227021 ↗
11. Assessment of overlay masonry strengthening system under in-plane monotonic and cyclic loading using the diagonal tensile test10.1016/j.conbuildmat.2015.07.040 ↗
12. Experimental in-plane behavior of tuff masonry strengthened with cementitious matrix-grid composites10.1061/(ASCE)1090-0268(2006)10:3(223) ↗
13. Quasi – static in – plane behavior of full – scale unreinforced masonry walls retrofitted using ferro – cement overlay10.1007/s42107-022-00447-7 ↗
14. The application of a reinforced plaster mortar for seismic strengthening of masonry structures10.1016/j.compositesb.2016.03.007 ↗
15. Ceroni, F.; Garofano, A.; Pecce, M. Finite Element Modelling of Masonry Panels Reinforced with FRP Grids. 2010.
16. Compressive and diagonal tension strengths of masonry prisms strengthened with amorphous steel fiber-reinforced mortar overlay
17. In-Plane strengthening of clay brick unreinforced masonry wallettes using ecc shotcrete10.1016/j.engstruct.2014.01.043 ↗
18. Shear behavior of masonry panels strengthened by frp laminates10.1016/S0950-0618(02)00043-0 ↗
19. Experimental response of masonry walls in-plane loading strengthened with gfrp strips10.1016/j.compstruct.2019.111735 ↗
20. The use of fibre reinforced polymers to improve seismic resistance of masonry10.1016/j.conbuildmat.2005.08.030 ↗
21. In-Situ and laboratory tests of old brick masonry strengthened with frp in innovative configurations and design considerations10.1007/s10518-014-9644-7 ↗
22. Diagonal compression testing of masonry panels with irregular texture strengthened with inorganic composites
23. Diagonal shear behavior of historic walls strengthened with composite reinforced mortar (crM)
24. Tensile capacity of adhesive anchors in damaged masonry
25. Ministero delle infrastrutture e dei Trasporti Decreto Ministeriale 17 Gennaio 2018 C.S.LL.PP. Aggiornamento Delle «Norme Tecniche per Le Costruzioni» 2018.
26. Earthquake Planning and Protection Organization of Greece EPPO CODE OF INTERVENTIONS (ΚΑΝ.ΕPΕ.). 2013, 1–337.
27. European Committee for Standardization EN 1998-3 Eurocode 8: Design of Structures for Earthquake Resistance - Part 3: Assessment and Retrofitting of Buildings Eurocode 2005.
28. Maddaloni, G. Analisi Sperimentale Del Comportamento Di Edifici in Muratura Rinforzati Con Tecniche e Materiali Innovativi, 2017.
29. Identification of shear parameters of masonry panels through the in-situ diagonal compression test10.1080/15583050802138634 ↗
30. The use of the diagonal compression test to identify the shear mechanical parameters of masonry10.1016/j.conbuildmat.2009.11.001 ↗
31. Testing masonry blockwork panels for orthotropic shear strength10.1016/j.conbuildmat.2019.04.116 ↗
32. Experimental and numerical insights on the diagonal compression test for the shear characterisation of masonry10.1016/j.conbuildmat.2021.122964 ↗
33. Diagonal compression tests on masonry walls strengthened with a gfrp mesh reinforced mortar coating
34. Experimental investigation of masonry panels externally strengthened with cfrp laminates
35. Masonry wall panels with gfrp and steel-cord strengthening subjected to cyclic shear: an experimental study10.1016/j.conbuildmat.2014.01.056 ↗
36. Nonlinear analysis of masonry panels strengthened with textile reinforced mortar10.1016/j.engstruct.2015.12.021 ↗
37. In-Plane shear strengthening of unreinforced masonry walls using gfrp jacketing
38. Gattesco, N.; Amadio, C.; Barelli, S.; Bedon, C.; Rinaldin, G.; Zorzini, F. Analisi Ciclica Di Pareti Murarie in Pietrame Rinforzate Mediante Intonaco Armato Con Rete in GFRP. 15 Convegno Nazionale “L’ingegneria sismica in Italia”, 30 giugno-4 luglio, Padova 2013, Id G11.
39. Stainless steel strip – a proposed shear reinforcement for masonry wall panels10.1016/j.conbuildmat.2019.03.197 ↗
40. Strengthening of unreinforced masonry using welded wire mesh and micro-concrete - behaviour under in-plane action10.1016/j.conbuildmat.2013.12.033 ↗
41. Retrofitting unreinforced masonry by steel fiber reinforced mortar coating: uniaxial and diagonal compression tests
42. Strengthening masonry infill panels using engineered cementitious composites10.1617/s11527-013-0176-4 ↗
43. Estimates for the stiffness, strength and drift capacity of stone masonry walls based on 123 quasi-static cyclic tests reported in the literature10.1007/s10518-017-0188-5 ↗
44. In-plane shear behaviour of unreinforced and jacketed brick masonry walls10.1016/j.soildyn.2013.03.006 ↗
45. Modelling of the in-plane behaviour of masonry walls strengthened with polymeric grids embedded in cementitious mortar layers10.1016/j.compositesb.2015.09.005 ↗
46. Astm International ASTM E 519:02 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages. ASTM Standard Guide, doi:10.1520/D2487-11.10.1520/D2487-11 ↗
47. ASTM E519/E519M-21 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages. ASTM International 2021, 5, doi:10.1520/E0519.10.1520/E0519 ↗
48. Parametric analyses of the response of masonry walls with reinforced plaster10.3390/app12105090 ↗
49. European Committee for Standardization EN 1996-1-1 Eurocode 6 - Design of Masonry Structures - Part 1-1: General Rules for Reinforced and Unreinforced Masonry Structures Eurocode; 2005;.
50. C293/C293M-16 standard test method for flexural strength of concrete (using simple beam with third-point loading).
51. C349–08 standard test method for compressive strength of hydraulic-cement mortars (using portions of prisms broken in flexure)
52. Deutsches Institut für Bautechnik ETA-19/0160: Hilti HIT-HY 270 with HAS-U. Metal Injection Anchors for Use in Masonry. 30.08.2019 2019.
53. C597–16 standard test method for pulse velocity through concrete
54. Application of sonic tests to the diagnosis of damaged and repaired structures10.1016/S0963-8695(00)00037-2 ↗
55. Sonic tomography and flat-jack tests as complementary investigation procedures for the stone pillars of the temple of s. nicolò 1’arena (italy)10.1016/S0963-8695(02)00066-X ↗
56. A new ultrasonic amplitude tomography approach, with validation on masonry tuff blocks10.1007/s10921-020-00693-2 ↗
57. Non-Destructive assessment of masonry pillars using ultrasonic tomography10.3390/ma11122543 ↗
58. Direct sonic and ultrasonic wave velocity in masonry under compressive stress
59. Porter, M.L. Sequential Phased Displacement (SPD) Procedure for TCCMAR Testing. In Proceedings of the Third Meeting of the Joint Technical Coordinating Committee on Masonry Research, U.S. - Japan Coordinated Earthquake Research Program; Tomamu, Japan, 1987.