Structural capacity of timber I-joist with flange notch: Experimental evaluation
Source abstract
Abstract
Abstract Timber I-joist is a common building construction element in North America and Europe due to its availability and easiness of passing the service conduits and ducts through openings in the Oriented Strand Board (OSB) web of I-joists. However, in order to provide passageway for service conduits and ducts, cuts and notches in the flange of I-joist are frequently made during construction without considering the structural integrity of the system. Flange stiffness is very critical as it provides the flexural strength to the I-joist, hence it is prohibited to cut or notch the I-joist flanges. This study examined ten series of timber I-joists with single flange notch at different locations in two span lengths (12 and 20 ft) and compared with the uncut I-joists to understand the reduction in load capacity, stiffness and failure mechanism of the tested I-joists. A total of 100 I-joist specimens, which included uncut and flange notched I-joists, were tested in this experimental study. It was observed that with the increase in distance of the notch from the support, the load carrying capacity of notched I-joists can even decrease up to 80% in comparison with the uncut I-joists. Moreover, the effects of notch location and notch size were also investigated, and it was found that these notches significantly affect the load carrying capacity of an I-joist.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wood Treatment and Properties · Structural Engineering and Vibration Analysis · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. American-Wood-Council. Guideline wood I-joists; 1999.
2. WIJMA. Establishing prefabricated wood I-joist composite EI; 2008.
3. Canadian-Standard-Association. CSA O86 – engineering design in wood; 2010.
4. Cold-formed steel reinforcement for improperly cut wood composite I-joists10.1061/(ASCE)1084-0680(2008)13:4(198) ↗
5. Finite element modelling of OSB webbed timber I-beams with interactions between openings10.1016/j.advengsoft.2005.03.027 ↗
6. Finite element modelling of anisotropic elasto-plastic timber composite beams with openings10.1016/j.engstruct.2008.09.007 ↗
7. Effect of openings on oriented strand board webbed wood I-joists10.1061/(ASCE)0733-9445(2007)133:1(145) ↗
8. Buckling of oriented strand board webbed wood I-joists10.1061/(ASCE)0733-9445(2005)131:10(1629) ↗
9. Predicting strength of wood I-joist with a circular web hole10.1061/(ASCE)0733-9445(2008)134:7(1229) ↗
10. Experimental evaluation of wood l-joists with web holes
11. Wood I-joists with excessive web openings: an experimental and analytical investigation10.1061/(ASCE)ST.1943-541X.0000013 ↗
12. ASTM-D5055. Standard specification for establishing and monitoring structural capacities of prefabricated wood I-joists; 2013. p. 1–33.
13. NASCOR. I-joist specifier guide. ; 2010.