Performance of lightweight thermal insulating mortars applied on brick substrate specimens and prototype wall
Source abstract
Abstract
The trend and the market of thermal mortars increased in recent years in both new and thermal retrofitting of building facades mostly due to their enhanced thermal performance. These mortars are formulated using different lightweight aggregates, thus allowing a significant reduction of both density and thermal conductivity. However, this latter aspect should not compromise either durability or mechanical performance. It is therefore of paramount importance to have reliable data on the performance of these innovative mortars, thus contributing to increase their efficiency and durability. The aim of this paper is to evaluate the thermophysical and mechanical performance of three commercially available and five experimentally designed lightweight thermal insulating mortars with several aggregates (expanded polystyrene, expanded cork, expanded clay, and silica aerogel) replacing sand in different percentages. These thermal mortars were studied on their fresh and hardened states and when applied on brick substrate specimens and a prototype wall, also evaluating the influence of the substrate on the performance of thermal mortars. Results show that lightweight thermal insulating mortars exhibited lower density, mechanical properties and thermal conductivity and higher capillary water absorption when compared to the control mortar (100 % sand aggregate). Moreover, mortars applied on the prototype wall showed enhanced mechanical properties and slightly higher thermal conductivity than those applied on brick substrate specimens. Nevertheless, all mortars with insulating aggregates (either applied on the brick substrate or prototype wall) presented a thermal conductivity lower than 0.2 W/(m.K), thus following the requirements of the EN 998-1 for thermal mortars. Results contribute towards the development of innovative and sustainable thermal insulating mortars with improved effectiveness and durability.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Aerogels and thermal insulation · Building materials and conservation · Hygrothermal properties of building materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. United Nations Environment Programme, 2021 Global Status Report for Buildings and Construction: Towards a Zero-emission, Efficient and Resilient Buildings and Construction Sector, Nairobi, 2021.
2. A cross-country comparison of the building energy consumptions and their trends10.1016/j.resconrec.2016.03.014 ↗
3. A review of the challenges posed by the use of vacuum panels in external insulation finishing systems10.1016/j.apenergy.2019.114028 ↗
4. Physical performance of industrial and EPS and cork experimental thermal insulation renders10.1016/j.conbuildmat.2018.11.151 ↗
5. Impact of natural and artificial ageing on the properties of multilayer external wall thermal insulation systems10.1016/j.conbuildmat.2021.125834 ↗
6. Cement-cork mortars for thermal bridges correction. Comparison with cement-EPS mortars performance10.1016/j.conbuildmat.2013.08.006 ↗
7. Lightweight thermal insulating coating mortars with aerogel, EPS, and vermiculite for energy conservation in buildings
8. Aerial lime-based mortars blended with a pozzolanic additive and different admixtures: A mineralogical, textural and physical-mechanical study10.1016/j.conbuildmat.2011.12.069 ↗
9. J. Maia, M. Pedroso, N. M. M. Ramos, I. Flores-Colen, M. Glória Gomes, L. Silva, Hygrothermal performance of a new thermal aerogel-based render under distinct climatic conditions, Energy Build. 243 (2021) 111001, https://doi.org/10.1016/j.enbuild.2021.111001.10.1016/j.enbuild.2021.111001 ↗
10. Hygrothermal characteristics of aerogel-enhanced insulating materials under different humidity and temperature conditions10.1016/j.enbuild.2017.09.079 ↗
11. Evaluation of the hygrothermal properties of thermal rendering systems10.1016/j.buildenv.2018.08.055 ↗
12. Retrofitting historic walls: feasibility of thermal insulation and suitability of thermal mortars10.3390/heritage4030114 ↗
13. Thermal mortar-based insulation solutions for historic walls: an extensive hygrothermal characterization of materials and systems10.1016/j.conbuildmat.2021.125640 ↗
14. Aerogel materials for heritage buildings: materials, properties and case studies10.1016/j.culher.2019.09.007 ↗
15. CEN, Specification for mortar for masonry. Part 1: rendering and plastering mortar. British Standard Institution. EN 998-1:2017, London, UK, 2017.
16. Experimental study of hygro-thermal characteristics of novel cement-cork mortars10.1016/j.conbuildmat.2020.121901 ↗
17. Silica-based aerogels as aggregates for cement-based thermal renders10.1016/j.cemconcomp.2016.06.013 ↗
18. Aerogel-based renders with lightweight aggregates: correlation between molecular/pore structure and performance10.1016/j.conbuildmat.2016.07.103 ↗
19. Th. Stahl, S. Brunner, M. Zimmermann, thermally insulating aerogel based rendering materials, W02014090790, 2014.
20. Thermo-hygric properties of a newly developed aerogel based insulation rendering for both exterior and interior applications10.1016/j.enbuild.2011.09.041 ↗
21. CEN, Methods of test for mortar for masonry – Part 2: Bulk sampling of mortars and preparation of test mortars. Comité Européen de Normalisation. EN 1015-2:1998, Brussels, Belgium, 1998.
22. CEN, Tests for mechanical and physical properties of aggregates – Part 3: Determination of loose bulk density and voids. Comité Européen de Normalisation. EN 1097-3:1998, Brussels, Belgium, 1998.
23. CEN, Methods of test for mortar for masonry – Part 11: Determination of flexural and compressive strength of hardened mortar. Comité Européen de Normalisation. EN 1015-11:1999, Brussels, Belgium, 1999.
24. Santos · 2012
25. CEN, Methods of test for mortar for masonry – Part 21: Determination of the compatibility of one-coat rendering mortars with substrates. Comité Européen de Normalisation. EN 1015-21:2002, Brussels, Belgium, 2002.
26. CEN, Methods of test for mortar for masonry – Part 3: Determination of consistence of fresh mortar (by flow table). Comité Européen de Normalisation. EN 1015-3:1999, Brussels, Belgium, 1999.
27. CEN, Methods of test for mortar for masonry – Part 6: Determination of bulk density of fresh mortar. Comité Européen de Normalisation. EN 1015-6:1999, Brussels, Belgium, 1999.
28. CEN, Methods of test for mortar for masonry – Part 10: Determination of dry bulk density of hardened mortar. Comité Européen de Normalisation. EN 1015-10:1999, Brussels, Belgium, 1999.
29. CEN, Natural stone test methods – Determination of the dynamic modulus of elasticity (by measuring the fundamental resonance frequency). Comité Européen de Normalisation. EN 14146:2004, Brussels, Belgium, 2004.
30. ASTM, Standard test method for thermal conductivity of plastic by means of transient line-source technique. ASTM International. ASTM D5930-09:2014, Pennsylvania, USA, 2014.
31. CEN, Methods of test for mortar for masonry – Part 18: Determination of water absorption coefficient due to capillary action of hardened mortar. Comité Européen de Normalisation. EN 1015-18:2002, Brussels, Belgium, 2002.
32. Efficacy of iron-based bioproducts as surface biotreatment for earth-based plastering mortars10.1016/j.jclepro.2019.117803 ↗
33. CEN, Concrete test on structures – Part 2: Non-destructive test. Determination of the sclerometric index. Comité Européen de Normalisation. EN 12504-2:2001, Brussels, Belgium, 2001.
34. LNEC, Test sheet FE Pa 25: Wall coating. Sphere impact test, Lisbon, Portugal, 1980 (in Portuguese).
35. RILEM, Water absorption under low pressure, Pipe method. Test N° II.4. Recommandations provisoires. RILEM TC 25-PEM, 201-202, 1980.
36. Laboratory and in-situ non-destructive methods to evaluate the thermal transmittance and behavior of walls, windows, and construction elements with innovative materials: a review10.1016/j.enbuild.2018.10.021 ↗
37. Fresh properties of cement-based thermal renders with fly ash, air lime and lightweight aggregates
38. Incorporation of phase change materials in an expanded clay containing mortar for indoor thermal regulation of buildings10.1016/j.est.2021.102385 ↗
39. Thermo-physical and mechanical characteristics of sand-based lightweight composite mortars with recycled high-density polyethylene (HDPE)10.1016/j.conbuildmat.2017.12.069 ↗
40. Physico-mechanical and thermal properties of composite mortars containing lightweight aggregates of expanded polyvinyl chloride10.1016/j.conbuildmat.2018.04.173 ↗
41. Assessment of test methods for the durability of thermal mortars exposure to freezing10.1617/s11527-019-1411-4 ↗
42. Aerogel-incorporated concrete: An experimental study10.1016/j.conbuildmat.2013.10.100 ↗
43. Physical and mechanical performance of cement-based renders with different contents of fly ash, expanded cork granules and expanded clay10.1016/j.conbuildmat.2018.10.043 ↗
44. Influence of brick and concrete substrates on the performance of renders using in-situ testing techniques
45. Silva · 2014
46. Expected render performance assessment based on impact resistance in situ determination10.1016/j.conbuildmat.2009.05.003 ↗
47. The comparison of thermal insulation types of plaster with cement plaster10.1016/j.jclepro.2014.07.042 ↗
48. Thermal conductivity measurement of thermal insulating mortars with EPS and silica aerogel by steady-state and transient methods10.1016/j.conbuildmat.2018.03.162 ↗
49. M. Pedroso, I. Flores-Colen, J. D. Silvestre, M. Glória Gomes, L. Silva, L. Ilharco, Physical, mechanical, and microstructural characterisation of an innovative thermal insulating render incorporating silica aerogel, Energy Build. 211 (2020) 109793, https://doi.org/10.1016/j.enbuild.2020.109793.10.1016/j.enbuild.2020.109793 ↗
50. The influence of moisture content on the thermal conductivity of external thermal mortars10.1016/j.conbuildmat.2016.12.166 ↗
51. Onsite monitoring of ETICS comparing different exposure conditions and insulation materials
52. Variability of in-situ testing on rendered walls in natural ageing conditions – rebound hammer and ultrasound techniques10.1016/j.conbuildmat.2018.02.152 ↗
53. Non-destructive mechanical and physical in-situ testing of rendered walls under natural exposure10.1016/j.conbuildmat.2019.116838 ↗
54. Effect of moisture content on heat and moisture transport properties of thermal insulation materials10.1016/j.enbuild.2012.07.002 ↗
55. Experimental assessment of the water content influence on thermos-acoustic performance of building insulation materials10.1016/j.conbuildmat.2017.10.028 ↗
56. Investigation of the thermal insulation performance of fibrous aerogel samples under various hygrothermal environment: laboratory tests completed with calculations and theory10.1016/j.enbuild.2020.109902 ↗
57. On-site performance assessment of rendering façades for predictive maintenance10.1108/02630801111132812 ↗