Optimisation of EMI shielding effectiveness: Mechanical and physical performance of mortar containing POFA for plaster work using Taguchi Grey method
Source abstract
Abstract
Abstract A waste material which is collected from palm oil mill called POFA is used as cement replacement in plastering work to overcome electromagnetic interference issue. This study proposes Taguchi-Grey method to assess the optimal mixtures in plastering work with multiple responses of POFA. The responses under investigation are EMI shielding effectiveness, 28-days compressive strength, 28-days flexural strength, shrinkage, slump flow, initial setting time, final setting time, water retention and air content. In the application of this method, POFA admixture percentage, topcoat powder-to-binder ratio, water-to-binder ratio, latex agent content, particle size of POFA, and curing condition are selected as control factors. From the results it had been demonstrated and verified that the optimal mixture has 20% of POFA admixture, 0% of topcoat powder-to-binder ratio, 0.6 of water-to-binder ratio, 10% of latex agent content, 140 µm of POFA particle size and with water immersion curing condition are the optimal mixture. After comparison of the verification results, the Taguchi Grey method is applicable for this study due to the confirmation result which is comparable and fulfill the standard (IEEE Std 299-1997, BS EN 998-1, ASTM C1329 , ASTM C596, and ASTM C1437 ) requirement.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Energy Technologies and Civil Engineering Innovations · Material Selection and Properties · Industrial Engineering and Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. Brain tumors among electronics industry workers10.1097/00001648-199603000-00004 ↗
2. Development of layer structured wave absorbing mineral wool boards for indoor electromagnetic radiation protection10.1016/j.jobe.2015.11.008 ↗
3. Optimization of the EMI shielding effectiveness of fine and ultrafine POFA powder mix with OPC powder using Flower Pollination Algorithm
4. The electromagnetic characteristics of fly ash and absorbing properties of cement-based composites using fly ash as cement replacement10.1016/j.conbuildmat.2011.07.062 ↗
5. Coke powder as an admixture in cement for electromagnetic interference shielding10.1016/S0008-6223(03)00289-6 ↗
6. Three-layer wave absorber using common building material for wireless LAN10.1049/el:20046426 ↗
7. Experimental and numerical analyses of electromagnetic attenuation properties of an L-shaped channel constructed by electromagnetic absorbing concrete
8. Mixed cement containing fly ash for masonry and plastering work10.1016/j.conbuildmat.2005.01.009 ↗
9. Cement based electromagnetic shielding and absorbing building materials10.1016/j.cemconcomp.2005.12.004 ↗
10. Materials for electromagnetic interference shielding10.1361/105994900770346042 ↗
11. Palm oil fuel ash as potential green micro-filler in polymer concrete10.1016/j.conbuildmat.2015.11.038 ↗
12. A. Standard, C618-12a standard specification for coal ash and raw or calcined natural pozzolan for use in concrete, ASTM International, (n.d.).
13. On blended cement and geopolymer concretes containing palm oil fuel ash10.1016/j.matdes.2015.09.140 ↗
14. Optimum preparation and thermal conductivity of novel glossy paint prepared from waste of palm oil fly ash composite10.15282/ijame.12.2015.19.0254 ↗
15. Fresh and hardened properties of lightweight foamed concrete with palm oil fuel ash as filler10.1016/j.conbuildmat.2013.04.015 ↗
16. Taguchi design and flower pollination algorithm application to optimize the shrinkage of triaxial porcelain containing palm oil fuel ash
17. Effect of palm oil fuel ash fineness on packing effect and pozzolanic reaction of blended cement paste10.1016/j.proeng.2011.07.045 ↗
18. Application of a weighted Grey-Taguchi method for optimizing recycled aggregate concrete mixtures10.1016/j.cemconcomp.2011.06.005 ↗
19. Application of Taguchi method for optimization of concrete strengthened with polymer after high temperature10.1016/j.conbuildmat.2015.01.039 ↗
20. Optimization of early flexural strength of pavement concrete with silica fume and fly ash by the taguchi method10.1080/10286600410001684562 ↗
21. Determination by the Taguchi method of optimum conditions for mechanical properties of high strength concrete with admixtures of silica fume and blast furnace slag10.1080/1028660031000081527 ↗
22. Investigating mix proportions of high strength self compacting concrete by using Taguchi method10.1016/j.conbuildmat.2008.02.014 ↗
23. A Taguchi approach for investigation of some physical properties of concrete produced from mineral admixtures10.1016/j.buildenv.2007.02.005 ↗
24. Properties of fly ash geopolymer concrete designed by Taguchi method10.1016/j.matdes.2011.10.036 ↗
25. Compressive strength of high strength class C fly ash-based geopolymers with reactive granulated blast furnace slag aggregates designed by Taguchi method10.1016/j.matdes.2013.07.035 ↗
26. Mechanical and dry sliding wear characterization of epoxy – TiO2 particulate filled functionally graded composites materials using Taguchi design of experiment10.1016/j.matdes.2010.08.011 ↗
27. Optimization of the pulsed current gas tungsten arc welding (PCGTAW) parameters for corrosion resistance of super duplex stainless steel (UNS S32760) welds using the Taguchi method10.1016/j.jallcom.2010.09.087 ↗
28. Laser welding of thin foil nickel – titanium shape memory alloy10.1016/j.optlaseng.2010.08.007 ↗
29. Phadke · 1989
30. Analysis of process parameters in surface grinding using single objective Taguchi and multi-objective grey relational grade10.1016/j.pisc.2016.04.077 ↗
31. Multi-response optimization in the development of oleo-hydrophobic cotton fabric using Taguchi based grey relational analysis10.1016/j.apsusc.2016.01.165 ↗
32. Optimisation of multiple quality characteristics of hardfacing using grey-based Taguchi method10.1016/j.matdes.2011.04.050 ↗
33. Parametric optimization of MIG welding on 316L austenitic stainless steel by grey-based Taguchi method10.1016/j.protcy.2016.08.204 ↗
34. Multi-response optimization of process parameters in friction stir welded AM20 magnesium alloy by Taguchi grey relational analysis10.1016/j.jma.2014.12.002 ↗
35. Multi-response optimisation of sintering parameters of Al-Si alloy/fly ash composite using Taguchi method and grey relational analysis10.1007/s00170-009-1973-3 ↗
36. N.O.L. Ching, S.C. Kiong, A. Zainudin, N.H.M. Nor, Y.S. Khee, Exploring the Potential of Palm Oil Fuel Ash (POFA) in EMI Shielding Effectiveness, 2017.
37. T.O. Standard, Standard Specification for aggregate for masonry mortar 1, 70 (2014) 53–54. doi:10.1520/C0144-11.2.
38. IEEE, IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures, 1997. https://doi:10.1109/IEEESTD.2007.323387.
39. Paul · 2006
40. C.I. Sfb, A guide to BS EN 998-1 and BS EN 998-2, 2015.
41. C.C.T. Speci-, T.D. Cores, C.C.T. Speci-, Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with), (n.d.) 1–3.
42. Cement and Concrete Research Cellulose ethers in fluence on water retention and consistency in cement-based mortars10.1016/j.cemconres.2010.09.004 ↗
43. ASTM C185: standard test method for air content of hydraulic cement mortar
44. M. Cabinets, M. Rooms, Standard Test Method for Flow of Hydraulic Cement Mortar 1, (2009) 6–7.
45. M. Rooms, H. Cements, Standard Test Method for Drying Shrinkage of Mortar Containing Hydraulic Cement 1, 2 (1971) 11–13.
46. An hybrid Taguchi-grey relational technique and cuckoo search algorithm for multi-criteria optimization in hard turning of AISI D3 steel
47. Gray evaluation method of concrete pavement comprehensive condition10.1061/(ASCE)0733-947X(1999)125:6(547) ↗
48. Hazard risk analysis of typhoon damage by applying grey system theory
49. Application of gray relational analysis to evaluate HMA with reclaimed building materials10.1061/(ASCE)0899-1561(2005)17:4(400) ↗
50. Practical expert diagnosis model based on the grey relational analysis technique10.1016/j.eswa.2007.11.046 ↗
51. Fisher · 1925
52. F. Aggregate, T. Concrete, M. Units, H. Cement, M. Rooms, R. Unit, B. Strength, C. Mortars, Mortar Cement 1, 14 (n.d.) 1–7.