Summary The effect of the quality of grouts on transmission lengths observed after the release of one of the mechanical anchorages was investigated by tests on nineteen grout-bonded post-tensioned concrete beams. The results showed that the transmission lengths for this condition were directly related to the compressive strengths of the grouts used. Grouts containing aluminium powder possess relatively high compressive strengths when expansion is restrained during setting, as in ducts, and consequently better bonding ability, and their use is therefore worthy of consideration.