A model specification for fiber reinforced non-participating permanent formwork panels for concrete bridge deck construction
Source abstract
Abstract
This paper discusses the development of a model design and construction specification for thin [less than 38 mm (1.5 in.)] non-participating permanent formwork panels (also known as, stay-in-place forms and lost forms) made of FRP or FRC materials with or without non-metallic reinforcements for use in the construction of concrete slabs, in particular, highway bridge decks. The use of such forms is motivated by the narrow gaps [less than 1 m (39.4 in.)] that are often found between the flanges of wide flange ‘‘bulb-T” prestressed girders that are becoming commonplace in the US highway construction industry. Bridge contractors have expressed an interest in using non-participating permanent forms to reduce the time and cost required in forming and stripping the plywood forms for such narrow gaps. A model specification that was developed to enable engineers to design and specify such forms is provided in the appendix to this paper. To develop the specification, different permanent formwork panels were fabricated and tested. These included (1) flat cementitious panels reinforced with short glass or polypropylene fibers, (2) flat cementitious panels reinforced with bi-directional FRP thin grids, (3) flat cementitious panels reinforced with unidirectional FRP reinforcing bars, and (4) off-the-shelf, commercially manufactured pultruded FRP thin-walled, ribbed planks. The specification provides guidance for the width of gaps permissible for each Class of system and details of prescriptive and performance tests that must be performed to qualify the products for use in construction.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Wrigley · 2001
2. Glass fibre reinforced cement permanent formwork
3. PCI. Recommended practice for glass fiber reinforced concrete panels, 4th ed., Committee on glass fiber reinforced concrete panels, Chicago (IL), USA: Precast/Prestressed Concrete Institute; 2001.
4. Bentur · 2007
5. Reinhardt · 2000
6. Brameshuber · 2002
7. Brameshuber W. Textile reinforced concrete – state-of-the-art report, RILEM TC 201-TRC, Bagneux, France: RILEM Publications SARL; 2006.
8. A model specification for FRP composites for civil engineering structures10.1016/S0950-0618(03)00041-2 ↗
9. Bank LC, Malla AP, Oliva MG, Russell JS, Bentur A, Shapira A. Specification and design of fiber reinforced bridge deck forms for use on wide flange T-girders, Wisconsin Highway Research Program Report WHRP 07-10; 2007. .
10. Malla AP. Development of a specification for thin stay-in-place forms for bridge deck construction. MS thesis, University of Wisconsin-Madison; 2007.
11. ASTM C1609-06. Standard test method for flexural performance of fiber-reinforced concrete (using beam with third-point loading). West Conshohocken (PA, USA): ASTM International; 2006.
12. ASTM C1399-07. Standard test method for obtaining average residual-strength of fiber-reinforced concrete. West Conshohocken (PA, USA): ASTM International; 2007.
13. ASTM E695-03. Method for measuring relative resistance of wall, floor, and roof construction to impact loading. West Conshohocken (PA, USA): ASTM International; 2003.
14. ACI 347-04. Guide to formwork for concrete, Farmington Hills (MI, USA): American Concrete Institute; 2004.
15. American Society of Civil Engineers. Design loads on structures during construction. Reston (VA, USA): ASCE 37-02, ASCE; 2002.
16. ACI 440.1R-06. Guide for the design and construction of structural concrete reinforced with FRP bars. Farmington Hills (MI, USA): American Concrete Institute; 2006.