Pressure required to cause cover cracking of concrete due to reinforcement corrosion
Source abstract
Abstract
Tests were carried out to investigate the magnitude of pressure created by corrosion products on steel in reinforced concrete that would cause surface cracking of the concrete cover. Test specimens were 150 mm cubes with 8 mm or 16 mm holes provided at various locations and formed by reinforcing bars. The cracking resistance of cover concrete was measured experimentally by pressurizing the holes, and an attempt was made at its prediction using plastic methods of analysis. Experimental failure pressures were found to be influenced by cover/bar diameter ratio, aggregate size, bar diameter, and bar location. The observed lack of correlation between tensile strength and failure pressure lends support to the suggestion made by other researchers that a fracture mechanics approach may be more appropriate. This suggestion was supported by an unsuccessful attempt to find a relationship between cover thickness and effective plastic strength.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Structural Behavior of Reinforced Concrete · Infrastructure Maintenance and Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Civil Engineering, University of Birmingham Edgbaston, Birmingham B15 2TT, UK
References (7)
Show source-provided references
1. 10.5006/1.331595610.5006/1.3315956 ↗
2. McLeish A. · 1986
3. Morinaga S. · 1988
4. Nielsen M. P. · 1984
5. Williamson S. J. The influence of concrete cover properties on the effects of reinforcement corrosion. PhD thesis, 1999, University of Birmingham.
6. Neilsen M. P. · 1978
7. Andreasen B. S. · 1989