Mechanically fastened hybrid composite strips for flexural strengthening of concrete beams
Source abstract
Abstract
Abstract While externally bonded fiber-reinforced polymer reinforcing has become an accepted technology for the flexural strengthening of reinforced concrete members, less information is available on flexural strengthening using mechanically fastened FRP (MF-FRP). This study presents the development of a vacuum-infused, hybrid glass–carbon MF-FRP system for the flexural strengthening of reinforced concrete beams. Two different FRP fabric architectures were considered to assess the impact of fiber orientation on behavior. The resistance of the MF-FRP composite strips to freeze–thaw cycling and saltwater submersion was assessed with single-fastener tension–bearing testing. Test results indicate that the MF-FRP system should display adequate residual capacity in typical cold-climate bridge applications. The flexural strengthening capabilities of MF-FRP composite strips were evaluated using four-point bending tests of MF-FRP-strengthened, steel-reinforced concrete beams and non-strengthened beams. The flexural test results for two glass–carbon MF-FRP reinforcing systems show an average increase in ultimate capacity of nearly 50% with good ductility. Flexural fatigue testing was conducted on four MF-FRP reinforced specimens. The cyclic flexural test results indicate that the strength gains that can be realized with the MF-FRP systems used here may be limited by fatigue performance, and that fatigue is an area that warrants further study.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. RC beams strengthened with GFRP plates. I: Experimental Study10.1061/(ASCE)0733-9445(1991)117:11(3417) ↗
2. RC beams strengthened with FRP plates. II: Analysis and parametric study10.1061/(ASCE)0733-9445(1991)117:11(3434) ↗
3. Carbon-fiber-reinforced polymers: modern materials in bridge engineering10.2749/101686692780617020 ↗
4. Strengthening of structures using carbon fibre/epoxy composites10.1016/0950-0618(95)00071-2 ↗
5. Strengthening of concrete structures with presetressed fibre reinforced plastic laminates
6. Flexural strengthening of beams using externally bonded composite materials10.1016/S0950-0618(09)90034-4 ↗
7. ACI Committee 440 · 2008
8. AASHTO · 2012
9. Flexural strengthening of reinforced concrete beams by mechanically attaching fiber-reinforced polymer strips10.1061/(ASCE)1090-0268(2004)8:3(203) ↗
10. Use of fiber reinforced polymer composites as reinforcing material for concrete10.1061/(ASCE)0899-1561(2002)14:3(191) ↗
11. Flexural strengthening of reinforced concrete beams using fasteners and fiber-reinforced polymer strips
12. Analysis of RC beams strengthened with mechanically fastened FRP (MF-FRP) strips10.1016/j.compstruct.2005.12.001 ↗
13. Performance of mechanically fastened FRP strengthened concrete beams in flexure10.1061/(ASCE)1090-0268(2008)12:3(257) ↗
14. Slip effects in reinforced concrete beams with mechanically fastened FRP strips10.1016/j.cemconcomp.2009.04.008 ↗
15. Strongwell Corporation. SAFSTRIP fiber reinforced strengthening strip. Available: . [accessed 16.06.14].
16. Modeling and verification of response of RC slabs strengthened in flexure with mechanically fastened FRP laminates10.1680/macr.2010.62.8.593 ↗
17. Modeling of flexural behavior of RC beams strengthened with mechanically fastened FRP strips10.1016/j.compstruct.2011.03.003 ↗
18. Analysis and design of RC structures strengthened with mechanically fastened FRP laminates: a review10.1016/j.compositesb.2013.06.038 ↗
19. Bank LC, Oliva MG, Arora D, Borowicz DT. Rapid strengthening of reinforced concrete bridges. Wisconsin highway research program report no. 03–06, Madison WI, USA: Wisconsin Department of Transportation; 2003.
20. Rizzo A, Galati N, Nanni A. Design and in-situ load testing of bridge no. 1330005. Rolla, MO, USA: Center for Infrastructure Engineering Studies, University of Missouri-Rolla; 2004.
21. Whittemore MD, Durfee RH. Low-cost rehabilitation with FRP strips. In: Proceedings of the international bridge conference 2011, Pittsburg, PA: Engineers’ Society of Western Pennsylvania; 2011.
22. Comparison of three flexural retrofit systems under monotonic and fatigue loads10.1061/(ASCE)1084-0702(2005)10:6(731) ↗
23. Flexural fatigue behavior of reinforced concrete beams strengthened with FRP fabric and precured laminate systems10.1061/(ASCE)1090-0268(2006)10:5(433) ↗
24. Finite-element analysis and load rating of flat slab concrete bridges10.1061/(ASCE)BE.1943-5592.0000461 ↗
25. The strength of bolted joints in multi-directional CFRP laminates10.1016/0010-4361(77)90027-1 ↗
26. The strength of bolted joints in glass fibre/epoxy laminates10.1016/0010-4361(85)90615-9 ↗
27. On the bearing strength of CFRP laminates10.1016/0010-4361(82)90006-4 ↗
28. Breton H. Mechanically fastened FRP flexural retrofit systems for reinforced concrete flat-slab bridges. M.S. thesis, Orono ME, USA: University of Maine; 2013.
29. Daniel · 2006
30. ASTM D3039 · 2008
31. ASTM C1645 · 2011
32. ASTM A370 · 2013
33. AASHTO · 2010