Experimental characterization of “non-engineered” masonry systems in a highly seismic prone area
Source abstract
Abstract
Abstract The mechanical characterization of in situ materials is one of the most important issues in the safety assessment of existing buildings, and – especially for masonry structures – represents a major source of uncertainty. In fact, the possibility of achieving a good “Level of Knowledge” is strictly related to the availability of comprehensive experimental tests on the structures, including destructive testing. In the case of masonry buildings, it is very difficult to extract a representative number of “undisturbed” samples or apply alternative techniques (such as in situ diagonal test) without causing unacceptable damages to the structure. The research work presented in the paper concerns the analysis and experimental characterization of a number of “non-engineered” masonry types commonly present in Calabria (a high seismic prone region located in Southern Italy). The definition of non-engineered is actually referred to self-constructed masonry buildings dated back to the first half of the 20th Century, in the absence of any kind of design and technical control about materials and procedures. The attention has been focused on a number of towns in the Province of Cosenza. Here, a survey has been carried out in order to detect and classify the structural features of the buildings: elements, textures, structural configurations. Afterwards, masonry elements and materials have been experimentally investigated (by testing samples taken on site and manufactured in laboratory). All data have been processed and compared with the Italian and European Standards, in order to derive a reference database for the local masonry building types. In a context where it would be very difficult to directly obtain the required experimental information, the objective is to improve the knowledge about local materials and their mechanical features, providing at the same time a reference methodological approach. In the absence of appropriate information (i.e., of a low level of knowledge) the safety verification and vulnerability assessment turn out to be very conservative. It is thence nearly impossible to provide an effective strategy for the rehabilitation/retrofitting against seismic risk, whereas the systematic, complete substitution of the existing residential housing would became the only solution, which is nowadays a non sustainable option.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Seismic Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. Ministero LL.PP. – Consiglio Superiore dei Lavori Pubblici, D.M. 14/01/2008 “Norme Tecniche per le Costruzioni”. Supplemento Ordinario no. 30 Gazzetta Ufficiale no. 29 del 4/02/2008.
2. CEN. Eurocode 8: Design of structures for earthquake resistance. Part 1: General rules, seismic actions and rules for buildings. Brussels; 2005.
3. Proposal of a methodology for assessing the reliability of in situ concrete tests and improving the estimate of the compressive strength10.1016/j.conbuildmat.2012.08.025 ↗
4. Assessment of compressive concrete strength in existing rc buildings by in situ diagnostics: statistical analysis of scatter in test data
5. Structural analysis of masonry historical constructions. classical and advanced approaches10.1007/s11831-010-9046-1 ↗
6. Computations on historic masonry structures10.1002/pse.120 ↗
7. Giuffré · 1996
8. Damage models for the seismic response of brick masonry shear walls. Part II: The continuum model and its applications10.1002/(SICI)1096-9845(199704)26:4<441::AID-EQE651>3.0.CO;2-0 ↗
9. Towards a multiscale analysis of periodic masonry brickwork: A FEM algorithm with damage and friction10.1016/j.ijsolstr.2005.10.004 ↗
10. Micromechanical analysis of periodic composites by prescribing the average stress10.1007/s12356-010-0010-4 ↗
11. Discrete element modeling of masonry structures10.1080/15583050601176868 ↗
12. Salerno G, Formica G, Gabriele S, Varano V. Stone-masonry new constructions: science and history in the service of beauty and environment, structures and architecture. In: Proc. of the 1st Int. Conference on Structures and Architecture, ICSA 2010, 2010. p. 196–203.
13. Modeling masonry historic buildings by multi-body dynamics
14. New discrete models and their application to seismic response analysis of structures10.1016/0029-5493(78)90217-0 ↗
15. Macroscale modeling of microstructure damage evolution by a rigid body and spring model10.2140/jomms.2009.4.551 ↗
16. A new discrete element model for the evaluation of the seismic behavior of unreinforced masonry buildings10.1016/j.engstruct.2012.02.039 ↗
17. Simplified out-of-plane modeling of three-leaf masonry walls accounting for the material texture10.1016/j.conbuildmat.2012.09.090 ↗
18. Nonlinear analysis of out-of-plane masonry façades: full dynamic versus pushover methods by rigid body and spring model10.1002/eqe.2224 ↗
19. Seismic assessment of bell towers of Mexican colonial churches10.4028/www.scientific.net/AMR.133-134.585 ↗
20. Comparative seismic vulnerability analysis on ten masonry towers in the coastal Po Valley in Italy10.1016/j.engstruct.2012.11.033 ↗
21. Seismic assessment of a medieval masonry tower in Northern Italy by limit, nonlinear static, and full dynamic analyses10.1080/15583058.2011.588987 ↗
22. Seismic analysis and strengthening design of a masonry monument by a rigid body spring model: the “Maniace Castle” of Syracuse10.1016/j.engstruct.2009.02.030 ↗
23. Investigation procedures for the diagnosis of historic masonries10.1016/S0950-0618(00)00018-0 ↗
24. Repair and investigation techniques for stone masonry walls10.1016/S0950-0618(97)00031-7 ↗
25. Experimental evaluation of shear and compression strength of masonry wall before and after reinforcement: deep repointing10.1016/j.conbuildmat.2006.11.021 ↗
26. Experimental study on the determination of strength of masonry walls10.1016/S0950-0618(03)00007-2 ↗
27. Identification of shear parameters of masonry panels through the in situ diagonal compression test10.1080/15583050802138634 ↗
28. Shaking table tests on multi-leaf stone masonry structures: analysis of stiffness decay
29. Binda L, Baronio G, Penazzi D, Palma M, Tiraboschi C. Caratterizzazione di murature in pietra in zona sismica: data-base sulle sezioni murarie e indagini sui materiali. In: Proc. 9th Italian National Conference on Earthquake Engineering, Torino, CD-ROM, 1999. (ref. 243) (in Italian).
30. Design choices and intervention techniques for repairing and strengthening of the Monza cathedral bell-tower10.1016/S0950-0618(02)00041-7 ↗
31. Cyclic testing of unreinforced masonry walls in two-way bending10.1002/eqe.654 ↗
32. Shear strength of brick masonry walls assembled with different types of mortar10.1016/j.conbuildmat.2012.11.107 ↗
33. Appraisal of masonry infill walls effect in the seismic response of RC framed buildings: a case study10.1016/j.engstruct.2011.08.043 ↗
34. About the influence of the infill panels over the collapse mechanisms actived under pushover analyses: two case studies10.1016/j.soildyn.2012.02.004 ↗
35. On the role of equivalent strut models in the seismic assessment of infilled RC buildings10.1016/j.engstruct.2012.04.005 ↗
36. Borri A, Corradi M, Speranzini E. Caratterizzazione meccanica di murature del XX secolo: alcune sperimentazioni. In: Proc. of 13th Italian Conference on Earthquake Engineering-ANIDIS. Italy: Bologna; 2009.
37. Repair and strengthening of historic masonry buildings in seismic areas. In: Int congr more than two thousand years in the history of architecture safeguarding the structure of our archit heritage Bethlehem, (Palestine)
38. Spinelli E, Analisi teorico-sperimentale sul comportamento di tipologie murarie non codificate presenti sul territorio regionale. Dissertation Thesis, 2001.
39. UNI ENV 1996: Eurocode 6 – Design of masonry structures, Milano, UNI, 1998.
40. UNI EN 771: Specification for masonry units, Milano, UNI, 2011.
41. UNI EN 772: Methods of test for masonry units, Milano, UNI, 2011.
42. UNI EN 196: Methods of testing cement, Milano, UNI, 2011.
43. UNI EN 1052: Methods of test for masonry, Milano, UNI, 2011.