Compressive behavior of frp tubular columns with recycled concrete lumps and flowable grout
Source abstract
Abstract
This paper presents a study on the compressive behavior of a novel type of highly deformable hybrid FRP tubular columns. The columns consist of an FRP tube filled with large-size recycled concrete lumps (RCLs) as aggregates and flowable grout as the binding material, and are thus termed FRP-RCL-Grout (F-R-G) columns. The use of large-size RCLs (e.g., up to 63 mm RCLs for 200 mm circular columns) leads to a relatively high recycling ratio and facilitates the manufacturing process. The flowable grout can be easily poured/pumped into the FRP tube, leading to ease of construction, while the FRP tube acts as an effective lateral confining device. The experimental part of the study involved compression tests on F-R-G columns and similar columns for comparison, with the main test variables being the FRP tube thickness, the size of the RCLs, the compressive strength of the concrete for producing RCLs and the WP ratio of the grout. The test results showed that F-R-G columns possess excellent structural behavior including ample ductility, and clarified the effects of the key parameters. In addition, based on the test results, a simple yet accurate model is proposed to predict the strength of F-R-G columns.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. 1992
2. Use of recycled aggregates in molded concrete bricks and blocks10.1016/S0950-0618(02)00019-3 ↗
3. An overview of study on recycled aggregate concrete in China (1996-2011)10.1016/j.conbuildmat.2011.12.074 ↗
4. Primary study on recycled-concrete-segment filled steel tubular members
5. Compressive behaviors of cylindrical concrete specimens made of demolished concrete blocks and fresh concrete10.1016/j.conbuildmat.2013.11.071 ↗
6. Compressive behaviors of cubes and cylinders made of normal-strength demolished concrete blocks and high-strength fresh concrete10.1016/j.conbuildmat.2015.01.027 ↗
7. Influences of size and shape of demolished concrete lumps on compressive behavior of compound concrete10.1016/j.conbuildmat.2020.121317 ↗
8. Behavior of reinforced concrete beams filled with demolished concrete lumps10.12989/sem.2011.40.3.411 ↗
9. Cyclic behavior of thin-walled square steel tubular columns filled with demolished concrete lumps and fresh concrete10.1016/j.jcsr.2012.05.003 ↗
10. Cyclic testing of thin-walled circular steel tubular columns filled with demolished concrete blocks and fresh concrete10.1016/j.tws.2013.01.008 ↗
11. Behavior of FRP-confined compound concrete containing recycled concrete lumps10.1061/(ASCE)CC.1943-5614.0000602 ↗
12. Theoretical model for seawater and sea sand concrete-filled circular FRP tubular stub columns under axial compression10.1016/j.engstruct.2018.01.017 ↗
13. Novel hybrid FRP tubular columns with large deformation capacity: Concept and behaviour10.1016/j.compstruct.2019.01.055 ↗
14. Barczak T. An overview of standing roof support practices and developments in the United States. Proceedings of the Third South African Rock Engineering Symposium. Johannesburg, Republic of South Africa: South African Institute of Mining and Metallurgy 2005; 301–334.
15. Reinforced sandy piles for low-rise buildings10.1016/j.proeng.2015.08.156 ↗
16. The method of calculating the settlement of weak ground strengthened with the reinforced sandy piles10.1051/matecconf/20167301015 ↗
17. Strengthening of clay by geogrid reinforced granular pile10.3328/IJGE.2009.03.03.377-386 ↗
18. Engineering of ground with granular piles: a critical review10.1080/19386362.2016.1145942 ↗
19. ASTM C39/C39M-21. Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens. West Conshohocken, PA: American Society for Testing Material; 2021.
20. BS EN 13369:2018. Common rules for precast concrete products. British standard Institution, London; 2018.
21. Minova. Safety Dada Sheet: CMT grout. Sydney, Australia; 2020.
22. Minova. Technical Dada Sheet: CMT grout. Sydney, Australia; 2020.
23. ASTM C942–15. Standard test method for compressive strength of grouts for preplaced aggregate concrete in the laboratory. West Conshohocken, PA: American Society for Testing Material; 2015.
24. ASTM D2290-19a · 2019
25. Effect of fiber angles on hybrid fiber-reinforced polymer–concrete–steel double-skin tubular columns under monotonic axial compression10.1177/1369433219895916 ↗
26. ASTM D2412–11. Standard test method for determination of external loading characteristics of plastic pipe by parallel-plate loading. West Conshohocken, PA: American Society for Testing Material; 2011.
27. Design-oriented stress–strain model for FRP-confined concrete10.1016/S0950-0618(03)00045-X ↗
28. Behavior of concrete columns confined by fiber composites10.1061/(ASCE)0733-9445(1997)123:5(583) ↗
29. Theoretical model for fiber-reinforced polymer-confined concrete10.1061/(ASCE)1090-0268(2007)11:2(201) ↗
30. FRP-confined concrete-encased cross-shaped steel columns: concept and behaviour10.1016/j.engstruct.2017.09.011 ↗
31. FRP-confined concrete in circular sections: review and assessment of stress–strain models10.1016/j.engstruct.2012.06.010 ↗