journal article·2024-02

Experimental testing of spliced glulam joints for large-span timber structures

Zheng Li, Yijing Wang, Chengyang He, Jiajia Ou, Ziwei Wang, Mingze Ao, Minjuan He

Publisher page

Abstract

In recent years, wood has become an increasingly popular building material for its environmental friendliness. Large-span timber structures are in high demand, of which the spliced joints play an important role for the main structural members. In this research, six specimens with two connection configurations, i.e., the slotted-in-steel-plate connection (SC) and the cover-plate connection (CC), were designed and subjected to cyclic loading tests. Besides the traditional data acquisition system, contact-free displacement measurement was also applied. The feasibility was verified since the moment-rotation curves obtained through the two methods showed strong consistency. Through the analysis of the mechanical properties of the joints, different methods for the determination of the yielding point of the specimens were compared and discussed. The test results show that the ultimate strength and stiffness of the CC connection were 59.04% and 187.7% higher than that of the SC connection, whereas the ductility of the former was 77.02% lower than that of the latter. Factors influencing on their mechanical properties were further analyzed. It is noted that while the ultimate strength is dominated by the steel plates, the stiffness and ductility depend more on the glulam elements and fasteners. Recommendations were also proposed as a design basis for the two types of connections.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Bamboo properties and applications · Tree Root and Stability Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. A plea for the efficient use of wood in construction10.1038/s41578-023-00534-4 ↗
2. Novel engineered wood and bamboo composites for structural applications: State-of-art of manufacturing technology and mechanical performance evaluation10.1016/j.conbuildmat.2020.118751 ↗
3. Crocetti R. Timber Structures for Large-Span Structures. vol. No. ICSENM 124, Prague, Czech Republic; 2016.10.11159/icsenm16.124 ↗
4. Research on flexural performance of glulam spliced joints connected by self-tapping screws in different arrangements10.1016/j.engstruct.2023.116146 ↗
5. Moment resisting on-site splice of large glulam elements by use of mechanically coupled long threaded rods10.1016/j.engstruct.2018.02.071 ↗
6. Experimental assessment and damage modelling of hybrid timber beam-to-steel column connections under cyclic loads10.1016/j.engstruct.2019.109682 ↗
7. Reinforced moment-resisting glulam bolted connection with coupled long steel rod with screwheads for modern timber frame structures10.1002/eqe.3789 ↗
8. Lateral Performance of Self-Centering Steel–Timber Hybrid Shear Walls with Slip-Friction Dampers: Experimental Investigation and Numerical Simulation10.1061/(ASCE)ST.1943-541X.0002850 ↗
9. Stiffness and slip in multi-dowel timber connections with slotted-in steel plates10.1016/j.engstruct.2022.114723 ↗
10. Assessment of the failure behaviour and reliability of timber connections with multiple dowel-type fasteners10.1016/j.engstruct.2018.05.081 ↗
11. Rotational performance of glulam bolted joints: Experimental investigation and analytical approach10.1016/j.conbuildmat.2019.03.002 ↗
12. Testing and analysis of screw-connected moment joints consisting of glued-laminated timbers and birch plywood plates10.1016/j.engstruct.2023.116356 ↗
13. A numerical study of methods to predict the capacity of multiple steel-timber dowel joints10.1007/s00107-008-0271-3 ↗
14. Experiments on dowel-type timber connections10.1016/j.engstruct.2012.09.010 ↗
15. Mechanical Performance Assessment of Bolted Glulam Joints with Local Cracks10.1061/(ASCE)MT.1943-5533.0002294 ↗
16. Self-tapping screws and threaded rods as reinforcement for structural timber elements – A state-of-the-art report10.1016/j.conbuildmat.2015.04.028 ↗
17. Flexural performance of spliced beam connected and reinforced with self-tapping wood screws10.1016/j.engstruct.2017.08.032 ↗
18. Mechanical performance of glulam beam-to-column connections with coach screws as fasteners
19. Moment-resisting bolted timber connections10.1680/stbu.2010.163.4.267 ↗
20. Parameter identification of ductile timber beam-to-steel column connections: Procedure and assessment10.1016/j.engstruct.2022.114179 ↗
21. Steel-timber composite beam-to-column joints: Effect of connections between timber slabs10.1016/j.jcsr.2018.09.019 ↗
22. Characterization of Complex Fracture Propagation in Naturally Fractured Formations Using Digital Image Correlation Technique
23. Flow structure and turbulence characteristics downstream of a spanwise suspended linear array10.1007/s10652-016-9465-0 ↗
24. Ottenhaus L., Li M., Nokes R. Application of Particle Tracking in Large Scale Timber Connection Testing, 2018.
25. Use of particle tracking velocimetry in timber material and connection testing10.1007/s00107-018-1376-y ↗
26. Experimental testing of full-scale glulam frames with buckling restrained braces10.1016/j.engstruct.2020.111081 ↗
27. Using self-tapping screw to reinforce dowel-type connection in a timber portal frame10.1016/j.engstruct.2018.10.066 ↗
28. Experimental investigation on screw reinforcement of timber members under compression perpendicular to the grain10.1016/j.engstruct.2022.115163 ↗
29. Experimental investigations into the mechanical performance of glulam dowel-type connections with either bolts or screws as fasteners10.1186/s10086-021-02002-5 ↗
30. EN 1995, Eurocode 5 (2008) Design of Timber Structure. European Committee for Standardization, CEN, Brussels.
31. Bejtka I., Blaß H. Reinforcements perpendicular to the grain using self-tapping screws 2004.
32. Dietsch P., Rodemeier S., Blaß H.-J. Transmission of perpendicular to grain forces using self-tapping screws, 2019.
33. Standard for design of timber structures. China’s National Standard
34. KonstruX Countersunk head, galvanised | Eurotec n.d. 〈https://www.eurotec.team/en/products/wood-construction-screws/konstrux-fully-threaded-screw/konstrux-countersunk-head-galvanised〉 (accessed October 25, 2023).
35. Streams. The University of Canterbury n.d. 〈https://www.canterbury.ac.nz/engineering/schools/cnre/software/streams/〉.
36. Williams M., Mohammad M., Alexander S. Determination of yield point and ductility of timber assemblies, Japan: 2008.
37. Commonwealth Scientific and Industrial Research Organization (CSIRO). Timber evaluation of mechanical joint systems 1996.
38. EN 1998–1, Eurocode 8: Design Of Structures For Earthquake Resistance - Part 1: General Rules, Seismic Actions And Rules For Buildings.
39. EN 1998–3, Eurocode 8: Design Of Structures For Earthquake Resistance - Part 3: Assessment and retrofitting of buildings.
40. Brittle failure of laterally loaded self-tapping screw connections for cross-laminated timber structures10.1016/j.engstruct.2022.114556 ↗
41. Ductile Moment-Resisting Timber Connections: A Review10.3390/buildings12020240 ↗
42. He M., Luo J., Li Z. KEY TECHNOLOGIES FOR PREFABRICATED TIMBER BUILDINGS n.d. https://doi.org/10.29173/mocs62.10.29173/mocs62 ↗
43. Influence of the Force Arm on the Flexural Performance of Prestressed Glulam Beams10.1155/2021/8831406 ↗
44. Study of glulam beams pre-stressed with pultruded GRP10.1016/j.compstruc.2005.03.021 ↗
45. Prestressed glulam timbers reinforced with steel bars10.1016/j.conbuildmat.2011.11.016 ↗
46. Ductility of timber joints under static and cyclic loads10.1680/stbu.10.00017 ↗
47. Experimental analysis of cold-formed steel-to-timber connections with inclined screws10.1016/j.istruc.2020.02.009 ↗
48. Experimental testing and numerical modelling of a heavy timber moment-resisting frame with ductile steel links10.1002/eqe.3025 ↗
49. Stiffness model for inclined screws in shear-tension mode in timber-to-timber joints10.1016/j.engstruct.2017.01.022 ↗
50. Theoretical and experimental analysis of timber-to-timber joints connected with inclined screws10.1016/j.conbuildmat.2010.03.007 ↗
51. Behaviour of small-scale glulam timber connections with slotted-in steel plates and dowel-type fasteners reinforced with self-tapping screws10.1016/j.conbuildmat.2023.132984 ↗