journal article·2025-12Open access

Experimental investigation of in-plane shear and compressive behaviour of dry-stacked interlocking concrete masonry

Mahmoud Zaki Abdelrahman, Khaled Galal

Abstract

Dry-stacked interlocking masonry (DSIM), also known as mortarless masonry, is an alternative construction technique that replaces conventional mortar joints with integrated interlocking shear keys. This system offers significant advantages, including faster construction times and improved cost efficiency. Nevertheless, a notable gap exists in the literature regarding the quantitative assessment of the in-plane shear strength of mortarless masonry systems, particularly with respect to the effects of grouting and reinforcement. Therefore, an experimental program was conducted involving fifteen DSIM assemblages, each measuring 1.20 m × 1.20 m, constructed using mortarless units called Sparlock, with various grouting conditions and vertical and horizontal reinforcement ratios. The assemblages were tested under diagonal compression loading to evaluate their in-plane shear performance in terms of shear strength, modulus of rigidity, and ductility. Additionally, six DSIM prisms were tested under uniaxial compression to evaluate the compressive behaviour of both grouted and ungrouted configurations. The experimentally obtained shear strength values in addition to DSIM walls from literature were further compared with the predicted values derived from existing design standards developed for conventional masonry construction to assess their applicability to dry-stacked interlocking systems. The experimental results showed that DSIM assemblages lacking horizontal reinforcement experienced premature failure, characterized by brittle sliding along the dry joints. In contrast, the horizontally reinforced specimens exhibited a more ductile response, characterized by progressive crack development and enhanced deformation capacity prior to failure. This could be attributed to the layout of the blocks, which is stack-patterned and not staggered. The increase in vertical reinforcement within fully grouted specimens led to a 78 % enhancement in shear strength compared to partially grouted assemblages. Similarly, increasing the horizontal reinforcement ratio in partially grouted assemblages resulted in a 33 % improvement. The shear strength predictions obtained from conventional masonry design equations showed poor correlation with the experimental results, primarily due to the fundamentally different shear-resisting mechanisms present in the DSIM systems. To address this limitation, an equation was proposed to calculate the shear strength for different DSIM systems. The findings of this study contribute to the quantification and potential codification of the shear behaviour of DSIM systems.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Civil and Structural Engineering Research · Wood Treatment and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Strength, behavior, and failure mode of hollow concrete masonry constructed with mortars of different strengths10.1016/j.conbuildmat.2016.12.112 ↗
2. Correlation between the performance of solid masonry prisms and wallettes under compression10.1016/j.jobe.2019.01.007 ↗
3. Influence of blocks and grout on compressive strength and stiffness of concrete masonry prisms10.1016/j.conbuildmat.2018.06.091 ↗
4. Prediction of compressive stress-strain curves of grouted masonry10.1016/j.conbuildmat.2019.116826 ↗
5. Structural behaviour of dry-stack interlocking block walling systems subject to in-plane loading
6. Development and evaluation of hollow concrete interlocking block masonry system10.70803/001c.130934 ↗
7. Capacity of innovative interlocking blocks under monotonic loading10.1016/j.conbuildmat.2012.08.002 ↗
8. Overcome of bed-joint imperfections and improvement of actual contact in dry-stacked masonry10.1016/j.conbuildmat.2019.117173 ↗
9. Characterisation and strategies for mitigation of the contact surface unevenness in dry-stack masonry10.1016/j.conbuildmat.2018.03.002 ↗
10. Impact of the height imperfections of masonry blocks on the load bearing capacity of dry-stack masonry walls10.1016/j.conbuildmat.2017.12.183 ↗
11. Experimental and numerical investigation on the compressive properties of interlocking blocks10.1016/j.engstruct.2020.111561 ↗
12. Strength characteristics of interlocking dry-stacked concrete block masonry
13. Behaviour of reinforced mortarless concrete masonry panels under axial compression: An experimental and analytical study10.1016/j.conbuildmat.2023.131097 ↗
14. Experimental and numerical evaluation of reinforced dry-stacked concrete masonry walls
15. Development and Performance Evaluation of Interlocking-Block Masonry10.1061/(ASCE)1076-0431(2000)6:2(45) ↗
16. Compressive strength in grouted dry-stack concrete block masonry: Experimental and analytical predictions10.1016/j.conbuildmat.2025.140411 ↗
17. Axial stress-strain models for grouted dry-stack concrete block masonry10.1016/j.istruc.2025.109385 ↗
18. Experimental characteristics of dry stack masonry under compression and shear loading
19. Experimental and numerical studies of the shear resistance capacities of interlocking blocks
20. In-plane and out-of-plane shear characteristics of reinforced mortarless concrete block masonry
21. Seismic behavior of load-bearing horizontal-hole interlocking concrete block masonry walls: An experimental investigation of variable configurations10.1016/j.engstruct.2024.117939 ↗
22. Experimental study on the in-plane seismic performance of fully grouted interlocking block walls
23. Behavior of post-tensioned dry-stack interlocking masonry shear walls under cyclic in-plane loading10.1016/j.conbuildmat.2018.11.149 ↗
24. Behavior of post-tensioned dry-stack interlocking masonry walls under out of plane loading10.1016/j.conbuildmat.2016.12.071 ↗
25. Influence of the number of keys on the shear strength of post-tensioned dry joints10.3989/mc.2013.07611 ↗
26. “The mechanical performance of concrete shear key for prefabricated structures,”10.1177/1369433220950618 ↗
27. Shear behavior of dry joints with castellated keys in precast concrete segmental bridges10.1061/(ASCE)BE.1943-5592.0000649 ↗
28. Shear strength of joints in precast posttensioned segmental bridges during 1959–2019, review and analysis10.1016/j.istruc.2019.06.007 ↗
29. Assessing the compressive behavior of dry-stacked concrete masonry with experimentally informed numerical models10.1061/(ASCE)ST.1943-541X.0002056 ↗
30. Canadian Standards Association (CSA), 2024, “CSA S304–24 Design of Masonry Structures,” Mississauga, Ontario, Canada.
31. ASTM International, 2024, “ASTM C140/C140M-24: Standard Test Methods for Sampling and Testing Concrete Masonry Units and Related Units.”
32. Canadian Standards Association (CSA), 2014, “CSA A179-14: Mortar and Grout for Unit Masonry.”
33. ASTM International, 2020, “ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products Authoring Organization: ASTM International,” West Conshohocken, PA, USA.
34. ASTM International, 2019, “ASTM E2126-19, Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Vertical Elements of the Lateral Force Resisting Systems for Buildings,” West Conshohocken, PA. United States.
35. ASTM International, 2022, “ASTM E519/E519M-22 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages,” West Conshohocken, PA. United States.
36. Canadian Standards Association (CSA), 2014, “CSA S304-14: Design of masonry structures,” Mississauga, Ontario, Canada.
37. ASTM International, 2018, “ASTM C1314 - 18: Standard Test Method for Compressive Strength of Masonry,” West Conshohocken, PA. United States.
38. TMS 402/602-22, 2022, “Building Code Requirements and Specification for Masonry Structures,” Longmont, CO, USA.
39. New Zealand Standard, 2004, “Design of reinforced concrete masonry structures, NZS 4230,” Wellington, New Zealand.
40. TMS 1430-21, 2021, “Design and Construction Guidelines for Dry-Stack Concrete Masonry,” Longmont, CO, USA.
41. Effect of Vertical Reinforcement on the In-Plane Shear Strength of Concrete Masonry Walls