Shear strength of high-strength bolts at elevated temperature
Source abstract
Abstract
Abstract Failure of bolted connections has frequently occurred during fire events. Because knowledge of the behavior of high-strength bolts while under fire is insufficient, there is further need to establish the behavior of high-strength bolt while under fire load. In this study, the behavior of high-strength bolts was investigated by a series of tests conducted at elevated temperatures with the parameters of temperature, number of bolts and the joint geometry analyzed. The strength deterioration and the deformation characteristics of the bolts were analyzed and discussed. Based on the experimental results, it was found that AIJ specification provides a conservative prediction for the strength of high-strength bolt under fire conditions, while BS5950 overestimated bolt strength. Eurocode 3 gave a good prediction on bolt strength.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (13)
Show source-provided references
1. Ball EF, Hinggins JJ. Installation and tightening of High-strength bolts, Transactions ASCE 1961;126. Part 2.10.1061/TACEAT.0008168 ↗
2. Surface Treatment of High-Strength Bolted Joints10.1061/JSDEAG.0001911 ↗
3. Kulak Geoffrey L, Fisher John W, Struik John HA. Guide to design criteria for bolted and riveted joints;1987.
4. AISC 2005, Manual of Steel Construction, LRFD, American Institute of Steel Construction; 2005.
5. The behavior of high-strength Grade 8.8 bolts in fire10.1016/0143-974X(94)00013-8 ↗
6. World Trade Center Building Performance Study: Data collection, preliminary observations and recommendations. Technical Report FEMA 403, Federal Emergency Management Agency, Washington, DC; 2002.
7. Architectural Institute of Japan, 1999, Recommendation for fire resistant design of steel structures; 1999.
8. Steel Construction Institute. Fire resistant design of steel structures – A Handbook to BS 5950: Part 8. SCI, Ascot, SCI-P-080; 1990.
9. Eurocode3: Design of steel structures Part1.2: General rules-structural fire design; 2005.
10. CNS 3934. Mechanical properties of bolts, screws, and studs, Taipei, Taiwan, ROC; 1998.
11. JSSIIB09. Sets of torque-shear-type high-strength bolt, hexagon nut and plain washer for structural joints. Soc Steel Constr Japan, 1-23, Tokyo, Japan; 1981.
12. Fang ZJ. Influence of fire temperature on the behavior of weld and bolt connection of fire-resistance steel structures. Master Thesis, National Taiwan University of Science and Technology; 1990.
13. Yang KC, Hsu RJ, Chen Y. Bearing and tensile strength of bolted butt joints under fire load. J Constr Steel Res, in preparation.