journal article·2017-05

Barcelona test for the evaluation of the mechanical properties of single and hybrid FRC, exposed to elevated temperature

D. Choumanidis, E. Badogiannis, P. Nomikos, A. Sofianos

Publisher page

Abstract

Abstract The mechanical behaviour of single and hybrid FRC mixtures, with one type of steel and two types of polypropylene fibres at 0.5% and 1.0% volume fractions, is investigated through the double punch Barcelona test. Indirect tensile strength and toughness characteristics are evaluated at ambient temperature and after heating of the specimens at 280 °C. It is shown that the modified toughness estimated through Barcelona test may be a suitable index to classify FRC in terms of ductility, both for the unheated and for the heated specimens. It was also found that hybrid FRC, containing an appropriate amount of different fibre types, is superior in terms of ductility compared to the single FRC. Finally, equations are proposed for the calculation of the Total Circumferential Opening Displacement (TCOD) values by using the axial displacement measurements, considering basic characteristics of the fibres and of FRC mixture, such as fibre’s length, rupture strength and volume fraction, respectively.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Innovative concrete reinforcement materials · Fire effects on concrete materials · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. ASTM C 1609/C 1609 M-05 · 2005
2. JSCE SF-4 · 1984
3. EN 14651:2005+A1:2007, Test method for metallic fibered concrete-Measuring the flexural tensile strength (limit of proportionality (LOP), residual), 2007.
4. UNE 83515 · 2010
5. W.F. Chen, Double punch test for tensile strength of concrete, Sept. 1969 (70-18) PB224770/AS (NTIS), 1969, doi: (70-18) PB224770/AS (NTIS).
6. W.F. Chen, Double Punch Test for Tensile Strength of Concrete, July 1973, 1973, doi: (70-18) PB224770/AS (NTIS).
7. Constitutive model for fibre reinforced concrete based on the Barcelona test10.1016/j.cemconcomp.2014.07.017 ↗
8. Double punch test to control the energy dissipation in tension of FRC (Barcelona test)10.1617/s11527-008-9391-9 ↗
9. S. Chao, N.B. Karki, J. Cho, R.N. Waweru, Use of double punch test to evaluate the mechanical performance of fiber reinforced concrete, in: High Perform. Fiber Reinf. Cem. Compos. vol. 6, 2012, pp. 27–34.10.1007/978-94-007-2436-5_4 ↗
10. Characterization of the properties of steel fiber reinforced concrete by means of the generalized Barcelona test10.1016/j.conbuildmat.2013.07.060 ↗
11. Generalization of the Barcelona test for the toughness control of FRC10.1617/s11527-011-9816-8 ↗
12. New analytical model to generalize the Barcelona test using axial displacement10.3846/13923730.2012.756425 ↗
13. Multidirectional double punch test to assess the post-cracking behaviour and fibre orientation of FRC10.1016/j.conbuildmat.2014.02.023 ↗
14. Evaluation of mechanical properties of steel-fibre-reinforced concrete exposed to high temperatures by double-punch test10.1016/j.conbuildmat.2015.01.042 ↗
15. Hybrid fiber reinforced concrete (HyFRC): fiber synergy in high strength matrices10.1007/BF02480516 ↗
16. High strength characteristics of cement mortar reinforced with hybrid fibres10.1016/j.conbuildmat.2010.11.008 ↗
17. Hybrid fibre-reinforced concrete under repeated loading10.1016/0029-5493(94)00945-U ↗
18. Mechanical properties of polypropylene hybrid fiber-reinforced concrete10.1016/j.msea.2008.05.037 ↗
19. ASTM C 469-02 · 2002 · vol. 4
20. ACI Committee 506R, Guide to Shotcrete, 1990.
21. High-temperature behaviour of HPC with polypropylene fibres – From spalling to microstructure10.1016/S0008-8846(01)00596-8 ↗
22. EN 206-1, Concrete – Part 1: Specification, performance, production and conformity, (2000) pp. 1–72.
23. ASTM C 143/C 143M-03 · 2003 · vol. 4
24. ASTM C 138/C 138M-01a · 2001 · vol. 4
25. SIDENOR, Product Data Sheet Steel Fibers INOMIX, 2016.
26. SIKA, SikaFiber PP-540/52, 2013.
27. SIKA, SikaFibers, 2013.
28. Potassium based geopolymer for passive fire protection of concrete tunnels linings10.1016/j.tust.2014.05.003 ↗
29. Efnarc, Specification and Guidelines for Testing of Passive Fire Protection for Concrete Tunnels Linings, 2006.
30. Investigations on the relationship between porosity, structure and strength of hydrated Portland cement pastes. I. Effect of porosity10.1016/0008-8846(85)90044-4 ↗
31. Toughness enhancement in steel fiber reinforced concrete through fiber hybridization10.1016/j.cemconres.2007.05.005 ↗
32. Performance synergy in hybrid fiber reinforced concrete under impact