Improved estimate and accurate measurement of thermal stresses in FRP tendon
Source abstract
Abstract
Abstract There is distinctive difference in the coefficient of thermal expansion (CTE) between fiber reinforced polymer (FRP) bar and surrounding mass, which may generate great transverse thermal pressure at their interface and cause significant reduction in bond strength of FRP tendon. However, the transverse thermal pressure predicted from previous analytical model has marked deviation from that obtained from experiment test. This paper presents an improved analytical model to exactly analyzing the transverse thermal pressure at the interface of FRP bar/surrounding mass and the three-dimensional thermal stresses of FRP bar. Then accurate measurement using fiber Bragg grating (FBG) sensor is conducted to obtain the transverse thermal pressure that agrees well with our theoretical result. Our work may be helpful in improving the thermal compatibility and bond performance of FRP tendon.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Fiber Optic Sensors · Advanced Fiber Laser Technologies · Advanced Photonic Communication Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Mechanical anchorage of FRP tendons – a literature review10.1016/j.conbuildmat.2011.11.049 ↗
2. Application of polymer composites in civil construction: a general review10.1016/j.compstruct.2007.06.007 ↗
3. Strengthening of rc beams using prestressed fiber reinforced polymers – a review10.1016/j.conbuildmat.2015.02.051 ↗
4. Experimental research on fracture behaviors of damaged CFRP tendons: fracture mode and failure analysis10.1016/j.conbuildmat.2016.03.036 ↗
5. Test and numerical simulation of large angle wedge type of anchorage using transverse enhanced CFRP tendons for beam string structure10.1016/j.conbuildmat.2017.03.150 ↗
6. Thermal compatibility and bond strength of FRP reinforcement in prestressed concrete applications10.1061/(ASCE)1090-0268(2007)11:5(459) ↗
7. Effects of radial stress at anchor zone on tensile properties of basalt fiber-reinforced polymer tendons10.1177/0731684415606857 ↗
8. Effects of thermal loads on concrete cover of FRP reinforced elements: theoretical and experimental analysis
9. H.A. Rahman, C.Y. Kingsley, D.A. Taylor, Thermal stress in FRP reinforced concrete, in: Proceeding of Annual Conference of the Canadian Society for Civil Engineering, Ottawa, Canada, 1995.
10. Transverse thermal expansion of FRP bars embedded in concrete10.1061/(ASCE)1090-0268(2005)9:5(377) ↗
11. Thermal effect on fiber reinforced polymer reinforced concrete slabs10.1139/L07-110 ↗
12. Numerical analysis of thermal stress-deformation in concrete surrounding FRP bars in hot region10.1016/j.conbuildmat.2012.08.047 ↗
13. Bond strength of glass fiber-reinforced polymer bars in concrete after exposure to elevated temperatures10.1177/0731684414555408 ↗
14. Experimental research on mechanical properties of transverse enhanced and high-temperature-resistant CFRP tendons for prestressed structure10.1016/j.conbuildmat.2015.09.003 ↗
15. Mechanical properties and bond characteristics of different fiber reinforced polymer rebars at elevated temperatures10.1016/j.conbuildmat.2017.03.113 ↗
16. Effect of high temperature on the bond performance between basalt fibre reinforced polymer (BFRP) bars and concrete10.1016/j.conbuildmat.2017.02.125 ↗
17. Effect of temperature and loading frequency on the fatigue life of a CFRP bar in concrete, ICCI-98, Tucson
18. Influence of fibre volume fraction and temperature on fatigue life of glass fibre reinforced plastics10.3934/matersci.2016.3.770 ↗
19. Behavior of FRP bars-reinforced concrete slabs under temperature and sustained load effects10.3390/polym6030873 ↗
20. Timoshenko · 1951 · 59
21. Integration of fibre Bragg grating strain sensors into composite electrical insulators10.1117/12.566607 ↗
22. Strain measurement using embedded fiber Bragg grating sensors inside an anchored carbon fiber polymer reinforcement prestressing rod for structural monitoring10.1109/JSEN.2009.2018355 ↗
23. Smart fiber-reinforced polymer anchorage system with optical fiber Bragg grating sensors
24. Stress analysis and detection of composite electrical insulators with embedded fiber Bragg grating sensors10.1166/sl.2012.2488 ↗
25. Monitoring on internal temperature of composite insulator with embedding fiber Bragg grating for early diagnosis
26. Analysis of the stress distribution of crimped pultruded composite rods subjected to traction10.1016/j.compositesb.2013.02.039 ↗
27. Analytical analysis of dynamic stress distribution of fiber reinforced polymer rod based on realistic boundary shear stress10.1016/j.compositesb.2017.07.043 ↗
28. Amadei · 1983 · 148
29. Fiber grating spectra10.1109/50.618322 ↗
30. Embedded fibre Bragg grating sensors for non-uniform strain sensing in composite structures10.1088/0957-0233/16/12/003 ↗