Dynamic characteristics changes of masonry arches exposed to elevated temperature
Source abstract
Abstract
In this study, the changes in the dynamic characteristics of masonry arches exposed to elevated temperatures were investigated experimentally and numerically. Firstly, the material properties were analyzed at different temperatures, ranging from 200°C to 800°C, through experimental tests. The constructed arch specimens were then subjected to heat to investigate the effects of elevated temperatures on their dynamic characteristics. Ambient vibration tests were performed before and after heating to identify natural frequencies and mode shapes. Furthermore, numerical models of the arches were developed, and a model updating procedure was implemented to minimize the differences between the numerical and experimental data. The findings indicated that elevated temperatures led to notable decreases in the compressive strengths of both the stone and the mortar. This decrease significantly degraded the stiffness of the masonry arch samples, consequently having a profound effect on their dynamic properties.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Health Monitoring Techniques · Fire effects on concrete materials · Masonry and Concrete Structural Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (79)
Show source-provided references
1. ABAQUS v2019, (2017) Dassault Systemes Simulia, Corp., Providence, RI, USA.
2. Resistance to fire of walls constituted by hollow blocks: experiments and thermal modeling10.1016/j.applthermaleng.2006.04.017 ↗
3. Dynamic identification of brick masonry semi-circular arches due to temperature and moisture10.1016/j.istruc.2023.02.022 ↗
4. The modal assurance criterion - twenty years of use and abuse
5. Behaviour of masonry wallettes made from a new concrete formulation under combination of axial compression load and heat exposure: experimental approach10.1016/j.engstruct.2012.09.028 ↗
6. Ambient vibration based seismic evaluation of isolated Gülburnu highway bridge10.1016/j.soildyn.2011.05.020 ↗
7. Dynamic response of a historical armory building using the finite element model validated by the ambient vibration test10.1177/1077546318755559 ↗
8. Non-destructive modal parameter identification of historical timber bridges using ambient vibration tests after restoration10.1016/j.measurement.2019.06.051 ↗
9. Experimental measurement-based FE model updating and seismic response of Santa Maria Church and its guesthouse building
10. Stress–strain curves for masonry materials exposed to fire action10.1016/j.firesaf.2014.08.005 ↗
11. Ambient vibration testing and empirical relation for natural period of historical mosques. Case study of eight mosques in Kermanshah, Iran10.1016/j.conbuildmat.2021.123191 ↗
12. ASTM C 1314-02a, Standard Test Method for Compressive Strength of Masonry Prisms, 2002. ASTM International, West Conshohocken, PA.
13. Dynamic characterisation of a heritage structure with limited accessibility using ambient vibrations10.3390/buildings13010192 ↗
14. High-temperature mechanical properties of concrete
15. Experimental and numerical studies on masonry after exposure to elevated temperatures10.1016/j.conbuildmat.2019.116926 ↗
16. Seismic response trends evaluation and finite element model calibration of an instrumented RC building considering soil–structure interaction and non-structural components10.1016/j.engstruct.2014.01.045 ↗
17. Canevari, F. (2020). Masonry arches in fire conditions, Master's Thesis, Politecnico di Torino University.
18. Integration of NDT, 3D parametric modelling, and nonlinear numerical analysis for the seismic assessment of a vaulted stone-masonry historical building
19. Natural period and vertical distribution of base shear in confined masonry buildings using ambient vibration test10.1007/s10518-021-01046-8 ↗
20. Optimal sensor placement for modal identification of bridge systems considering number of sensing nodes10.1061/(ASCE)BE.1943-5592.0000594 ↗
21. Shear strength of unreinforced masonry panels
22. Design of masonry structures, Canadian Standards Association (CSA), Mississauga
23. Influence of the ground on the structural identification of a bell-tower by ambient vibration testing10.1016/j.soildyn.2021.107102 ↗
24. Structural performance of authentic architectural heritage designs: A masonry monument in Western Anatolia. Frontiers of Architectural
25. Drysdale · 1994
26. EN 1992-1-2, 2004. Eurocode 2: Design of Concrete Structures – Part 1-2: General Rules Structural Fire Design, European Committee for Standardisation (CEN), Brussels.
27. EN 1996-1-1, 2005. Eurocode 6: Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures, European Committee for Standardisation (CEN), Brussels.
28. Assessing the impact of retrofitting on structural safety in historical buildings via ambient vibration tests10.1016/j.conbuildmat.2017.12.154 ↗
29. Review of finite element model updating methods for structural applications10.1016/j.istruc.2022.05.041 ↗
30. Masonry arches and vaults under fire
31. FEMA-273, 1997. FEMA356 Nehrp Guidelines for The Seismic Rehabilitation of Buildings, Building Seismic Safety Council, Washington, D.C. USA.
32. Dynamic analysis of a cable-stayed deck steel arch bridge10.1016/j.jcsr.2006.11.001 ↗
33. Meta-model assisted continuous vibration-based damage identification of a historical rammed earth tower in the Alhambra Complex
34. Ambient vibration testing of historic masonry towers for structural identification and damage assessment10.1016/j.conbuildmat.2006.01.007 ↗
35. One-year dynamic monitoring of a historic tower: damage detection under changing environment10.1007/s11012-016-0482-3 ↗
36. Expeditious damage index for arched structures based on dynamic identification testing10.1016/j.conbuildmat.2020.120236 ↗
37. Modulus of elasticity and compressive strength of tuff masonry: Results of a wide set of flat-jack tests10.3390/buildings10050084 ↗
38. Experimental investigation on acceptable difference value in modal parameters for model updating using RC building models10.1080/10168664.2018.1517019 ↗
39. Structural condition assessment of a historical masonry school building using experimental and numerical methods10.1007/s13349-022-00597-x ↗
40. Automatic estimation of post-fire compressive strength reduction of masonry structures using deep convolutional neural network10.1007/s10694-022-01275-6 ↗
41. Evaluating the deterioration effects of building stones using NDT: the Küçükköy Church, Cappadocia Region, central Turkey10.1007/s10064-018-1339-x ↗
42. Wireless-based identification and model updating of a skewed highway bridge for structural health monitoring10.3390/app10072347 ↗
43. Model updating of the vehicle-track coupled system based on in-situ dynamic measurements10.1016/j.conbuildmat.2021.123861 ↗
44. Sensor placement optimization for structural modal identification of flexible structures using genetic algorithm10.1007/s12206-015-0606-z ↗
45. Experimental and numerical modal analysis of a cross laminated timber floor system in different construction states10.1016/j.conbuildmat.2022.128032 ↗
46. Changes in the engineering properties of marble in fire-exposed columns10.1016/j.ijrmms.2005.09.007 ↗
47. Effect of restoration interventions on the seismic behavior of historical masonry buildings: The case of Molla Siyah mosque10.1016/j.engfailanal.2023.107206 ↗
48. Deterioration of different stones used in historical buildings within Nigde province, Cappadocia10.1016/j.conbuildmat.2013.07.033 ↗
49. Recommendations for restoration of ancient buildings and the survival of a masonry chimney10.1016/j.conbuildmat.2005.08.026 ↗
50. MSJC, 2002. Building code requirements for masonry structures, Masonry Standards Joint Committee (MSJC). ACI 530-02, ASCE 5-02, TMS 402, 2.
51. Review of strengthening techniques and mechanical testing for unreinforced masonry
52. Finite element modelling of compartment masonry walls in fire10.1016/S0045-7949(03)00212-8 ↗
53. Compartment Masonry Walls in Fire Situations10.1007/s10694-006-7509-6 ↗
54. Behavior of clay hollow-brick masonry walls during fire Part-1, experimental analysis10.1016/j.firesaf.2012.06.001 ↗
55. The behaviour of masonry wall ssubjected to fire Modelling and parametrical studies in the case of hollow burnt-clay bricks10.1016/j.firesaf.2008.12.006 ↗
56. Experimental and numerical analysis on the structural fire behaviour of three-cell hollowed concrete masonry walls10.1016/j.engstruct.2020.111439 ↗
57. OMA, 2006. Operational Modal Analysis, Release 4.0. Structural Vibration Solution A/S, Denmark.
58. Determination of the regions used as facing and building stone according to the material characteristics in an andesite quarry10.1016/j.enggeo.2011.01.005 ↗
59. Effects of high temperature on physico-mechanical properties of Turkish natural building stones10.1016/j.enggeo.2014.10.006 ↗
60. Effects of temperature variations on the modal properties of masonry structures: an experimental-based numerical modelling approach10.1016/j.istruc.2023.04.080 ↗
61. PULSE, 2006. Analyzers and Solutions, Release 11.2. Bruel and Kjaer, Sound and Vibration Measurement A/S, Denmark.
62. Ramos, L.F. 2007. Damage identification on masonry structures based on vibration signatures. Doctoral dissertation, Universidade do Minho, Portugal.
63. Damage identification on arched masonry structures using ambient and random impact vibrations10.1016/j.engstruct.2009.09.002 ↗
64. A discussion about the Douglas-Reid model updating method and its prospective application to continuous vibration-based SHM of a historical building10.1016/j.engstruct.2022.115058 ↗
65. Experimental and theoretical investigation on masonry after high temperature exposure10.1007/s11340-011-9493-0 ↗
66. Residual mechanical parameters of masonry exposed to fire: a new numerical approach10.4028/www.scientific.net/AMR.1119.700 ↗
67. Sahlin, S. (1971). Structural Masonry. Englewood Cliffs, New Jersey: Prentice-Hall Inc.
68. Detection of structural damage through changes in frequency: a review10.1016/S0141-0296(96)00149-6 ↗
69. Model updating of historical belfries based on OMA identification techniques10.1080/15583058.2020.1723735 ↗
70. TEC, 2018. TEC2018 Turkey Earthquake Building Codes, Disaster and Emergency Management Presidency-Earthquake Department, Ankara.
71. TS 500, 2000. Design and Construction Rules of Reinforced Concrete Structures, Turkish Standards Institute (TSI), Ankara, Turkey.
72. TS EN 1052-1, 2000. Masonry- Test methods - Part 1: Determination of compressive strength, Turkish Standards Institute (TSI), Ankara.
73. TS EN 12390-3, 2019. Testing hardened concrete compressive strength of test specimens, Turkish Standards Institute (TSI), Ankara.
74. TS EN 196-1, 2016. Methods of testing cement Determination of strength, Turkish Standards Institute (TSI), Ankara.
75. TS EN 772-1, 2002. Masonry Units, test methods - Part 1: Determination of Compressive Strength, Turkish Standards Institute (TSI), Ankara.
76. Seismic assessment of historical masonry towers by means of simplified approaches and standard FEM10.1016/j.conbuildmat.2016.01.025 ↗
77. Durability assessments of rare green andesites widely used as building stones in Buca (Izmir)
78. Technology for condition and performance evaluation of highway bridges10.1007/s13349-020-00403-6 ↗
79. Determining minimum intervention in the preservation of heritage buildings10.1080/15583058.2019.1645237 ↗