journal article·2024-12

Mechanical behavior of half-grouted sleeve connection under the coupling of sulfate erosion and dry-wet cycles

Tongxing Wang, Jianian Wen, Menghan Hu, Qiang Han

Publisher page

Abstract

The half-grouted sleeve connection (HGSC) is commonly used in precast concrete (PC) structures due to its convenient fabrication method, however, the long-term mechanical properties of the HGSC in corrosive environments remain unclear. Therefore, the mechanical behavior of HGSC under the coupling of sulfate erosion and dry-wet cycles (DWCs) is investigated in this paper. A total of 24 specimens with 4d and 8d embedded lengths were designed and subjected to sulfate erosion with different DWCs. The failure modes and mechanical properties of HGSCs with different embedded lengths and DWCs were comparatively analyzed. Following this, a modified bond-slip model considering sulfate erosion was proposed and validated against the measured data. The test results indicated that the failure modes of HGSCs with 4d and 8d embedded lengths were rebar fracture and slip failure, respectively. As the number of sulfate erosions increased, the performance indicators of HGSCs gradually decreased. After 180 dry-wet cycles (DWCs), the average deformation and average slip under peak load for HGSCs with an embedded length of 8d decreased by 36.6 % and 37.7 %, respectively. In contrast, for HGSCs with an embedded length of 4d, the corresponding values increased by 3.0 % and 40.1 %, respectively. The predicted bond-slip model of HGSC considering sulfate erosion agreed well with the experimental results, and it can be useful in the life-cycle modeling of the PC structures with HGSCs.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Geotechnical Engineering and Underground Structures · Grouting, Rheology, and Soil Mechanics · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (66)

Show source-provided references
1. Grouted sleeve connection for precast concrete members
2. Mechanical properties of large-diameter semi-grouted sleeve connections for railway platform canopies10.1016/j.istruc.2023.03.002 ↗
3. Seismic performance of precast RC and RC/ECC composite columns with grouted sleeve connections10.1016/j.engstruct.2019.03.022 ↗
4. Seismic experimental study on a precast concrete beam-column connection with grout sleeves10.1016/j.engstruct.2017.09.027 ↗
5. Experimental and numerical investigation of cast-in-situ concrete under external sulfate attack and drying-wetting cycles[J]10.1016/j.conbuildmat.2020.118789 ↗
6. Investigating the failure process of concrete under the coupled actions between sulfate attack and drying-wetting cycles by using X-ray CT10.1016/j.conbuildmat.2016.01.040 ↗
7. Durability of concrete exposed to leaching and external sulphate attacks10.1016/j.cemconres.2009.07.021 ↗
8. Study of deterioration of concrete exposed to different types of sulfate solutions under drying-wetting cycles10.1016/j.conbuildmat.2016.04.094 ↗
9. Degradation progress of Portland cement mortar under the coupled effects of multiple corrosive ions and drying-wetting cycles10.1016/j.cemconcomp.2020.103629 ↗
10. Effect of sulfate attack, drying-wetting cycles and freezing-thawing cycles on reinforced concrete columns under eccentric loads10.1016/j.istruc.2022.10.011 ↗
11. Resistance of concrete against combined attack of chloride and sulfate under drying wetting cycles10.1016/j.conbuildmat.2015.12.151 ↗
12. Influence of compressive stress on chloride transport in the interfacial zone of precast and cast-in-place concrete10.1002/suco.201900147 ↗
13. Chloride transport in interfacial zone of new–old concrete joints of precast prestressed concrete bridges under fatigue load10.1061/(ASCE)MT.1943-5533.0004412 ↗
14. Steel corrosion in precast reinforced concrete column-beam joint with grouted sleeve connections under chloride-rich environment
15. Seismic performance of pre-fabricated segmental bridge piers with grouted splice sleeve connections10.1016/j.engstruct.2020.111668 ↗
16. Behavior of a novel corrugated grouted sleeve splice for prefabricated construction under uniaxial tensile loading
17. Seismic experimental study on a precast concrete beam-column connection with grout sleeves10.1016/j.engstruct.2017.09.027 ↗
18. External sulfate attack to reinforced concrete under drying-wetting cycles and loading condition: Numerical simulation and experimental validation by ultrasonic array method10.1016/j.conbuildmat.2017.02.064 ↗
19. Deterioration of marine concrete exposed to wetting-drying action10.1016/j.jclepro.2020.123383 ↗
20. Effect of sulfate attack on reinforced concrete columns confined with CFRP Sheets under axial compression10.1061/(ASCE)CC.1943-5614.0001151 ↗
21. Structural performance of circular columns confined by recycled GFRP stirrups and exposed to severe conditions10.1016/j.hbrcj.2012.09.006 ↗
22. Behavior of normal reinforced concrete columns exposed to different soils.10.1051/matecconf/201816204018 ↗
23. Proposal and experimental verification of enhancement method for half-grouted sleeve connection quality[J]10.1016/j.conbuildmat.2024.135161 ↗
24. Comparison of tensile mechanical properties of half grouted sleeve connection at elevated and post-elevated temperature: an experimental study10.1016/j.conbuildmat.2024.136723 ↗
25. Experimental bond behavior of deformed rebars in half-grouted sleeve connections with insufficient grouting defect10.1016/j.conbuildmat.2018.07.050 ↗
26. Evaluation of common defects of grouted sleeve connectors
27. Experimental investigation of mechanical behaviour of rebar in steel half-grouted sleeve connections with defects in water/binder ratio
28. Experimental investigation of mechanical properties of steel half-grouted sleeve splice with rebar bonding defects
29. Experimental investigation of uncertain factors on the mechanical properties of half-grouted sleeve connected with large-diameter high-strength reinforcement
30. Bond strength prediction model of defective grout materials in half-grouted sleeve connections under uniaxial and cyclic loadings10.1016/j.conbuildmat.2022.128981 ↗
31. Experimental investigation on the connection performance of defect detectable and repairable half-grouted sleeve under cyclic loads[J]10.1016/j.conbuildmat.2022.126593 ↗
32. Development and validation of a defect detection and repair method for half grouted sleeve connection
33. Experimental study on mechanical properties of corroded grouted sleeve splice10.1016/j.conbuildmat.2023.134797 ↗
34. Grouted sleeve connections used in precast reinforced concrete construction-Experimental investigation of a column-to-column joint10.1016/j.engstruct.2016.09.021 ↗
35. Finite element modeling approach for precast reinforced concrete beam-to-column connections under cyclic loading10.1016/j.engstruct.2018.07.055 ↗
36. Seismic behavior of precast reinforced concrete column-to-foundation grouted duct connections10.1007/s10518-021-01133-w ↗
37. Standard, C., 2009. Test Methods of Long-Term Performance and Durability of Ordinary Concrete. GB/T 50082e2009.
38. C1012, A.S., 2018. Standard Test Method for Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate Solution. American Society for Testing and Materials, West Conshohocken, PA.
39. GJ 355-2015, 2015, Technical specification for grout sleeve splicing of rebars. Beijing: China Architecture & Building Press..
40. Non-proprietary bar splice sleeve for precast concrete construction10.1016/j.engstruct.2014.10.045 ↗
41. JGT408-2019, Cementitious grout for sleeve of rebar splicing, Standards Press of China, Beijing, 2019. (in Chinese).
42. CEB-FIP, 1993, Model Code 1990. Thomas Telford Ltd., London..
43. Tensile capacity of grouted splice sleeves10.1016/j.engstruct.2015.12.023 ↗
44. Seismic column-to-footing connections using grouted splice sleeves
45. Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete columns-to-cap beam joints in accelerated bridge construction10.15554/pcij.03012015.80.103 ↗
46. ACI 318, Building code requirements for structural concrete (ACI 318–14) and commentary (ACI 318R–14), American Concrete Institute, Farmington Hills, MI, 2014.
47. A simplified model of reinforced concrete stick-slip instantonal relationship
48. Experimental investigation on UHPC-based gravity-type half grouted sleeve connections under tensile and cyclic loadings
49. Bond stress–slip model for steel bars in unconfined or steel, FRC, or FRP confined concrete under cyclic loading10.1061/(ASCE)0733-9445(2009)135:5(509) ↗
50. Equivalent stress-strain model of half grouted sleeve connection under monotonic and repeated loads: Experiment and preliminary application10.1016/j.engstruct.2022.114247 ↗
51. Tensile capacity of grouted splice sleeves10.1016/j.engstruct.2015.12.023 ↗
52. Effect of grout properties on bond behavior of grouted pipe splice10.1007/s12205-017-0034-y ↗
53. On the early-age bond-slip behavior of an eccentric bar embedded in a grouted sleeve10.1016/j.engstruct.2019.04.020 ↗
54. Experimental study on a novel UHPC grout-filled pipe sleeve with mechanical interlocking for large-diameter deformed bars10.1016/j.engstruct.2020.111358 ↗
55. Mechanical performance for defective and repaired grouted sleeve connections under uniaxial and cyclic loadings10.1016/j.conbuildmat.2019.117233 ↗
56. Evaluation of common defects of grouted sleeve connectors
57. Bond characteristics in post-yield range of deformed bars10.2208/jscej.1987.378_213 ↗
58. Hawkins N M. Beam bar anchorage in exterior column-beam connections
59. Viwathanatepa · 1979
60. Modeling of strain penetration effects in fiber-based analysis of reinforced concrete structures
61. FIB Task Group on Bond Models, Bond of reinforcement in concrete, Bulletin 10, Lausanne, Switzerland, Aug. 2000, 427 pp.
62. Reinforcement anchorage slip under monotonic loading10.1061/(ASCE)0733-9445(1992)118:9(2421) ↗
63. R. Eligehausen, E. Popov, V. Bertero, 1983, Local bond stress-slip relationships of deformed bars under generalized excitations. Report No UCB/EERC 83-23, California: University of California, Berkeley.
64. CEB-FIP, 2010, fib Model Code for Concrete Structures 2010. Lausanne, Switzerland: Thomas Thelford..
65. Experimental study on flexural capacity of corroded RC slabs reinforced with basalt fiber textile[J]10.3390/app11010144 ↗
66. Experimental investigation on the dynamic behavior of grouted splice sleeve connector under fast tensile loading