Masonry spandrels reinforced by thin-steel stripes: Experimental program on reduced-scale specimens
Source abstract
Abstract
Abstract This paper presents the results of an experimental program conducted on H-shaped reduced-scale reinforced masonry spandrels subjected to monotonic loadings. It summarized tests units, test set-up and experimental results relative to seventeen samples reinforced by thin-steel stripes arranged with different configurations, and compared with those unreinforced. The first configuration comprised masonry spandrels strengthened by unbonded horizontal and diagonal steel stripes (i.e., stripes connected by means of threaded rods to the nodal area of the panel), while the second masonry spandrels reinforced by bonded horizontal stripes (i.e., stripes connected with 5 or 13 threaded rods over the spandrel length). For each reinforcement configuration, slender, intermediate and squat slenderness ratios have been considered for the samples. The conducted research investigated the effectiveness of the reinforcement to enhance the seismic response of the spandrels. Test results demonstrated that the application of steel stripes is beneficial in changing the failure modes from shear-dominated into flexural-dominated, especially for intermediate and squat panels prone to brittle shear mechanisms. Despite that increases of strength are reduced with respect to unreinforced samples, when reinforced the post-peak response changes significantly being it characterized by a remarkable ductile response for whatever spandrels’ slenderness ratios.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Performance of masonry buildings and churches in the 22 February 2011 Christchurch earthquake10.5459/bnzsee.44.4.279-296 ↗
2. L. Sorrentino, S. Cattari, F. da Porto, G. Magenes, A. Penna. Seismic behavior of ordinary masonry buildings during the 2016 central Italy earthquakes. Bull of Eart Eng. 17. 2019. 5583-5607.10.1007/s10518-018-0370-4 ↗
3. Sustainable Mortars for Application in the Cultural Heritage Field10.3390/ma14030598 ↗
4. Fragility curves for Italian URM buildings based on a hybrid method10.1007/s10518-021-01155-4 ↗
5. N. Mendes, P.B. Lourenco, A. Campos-Costa, A. 2014. ‘Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance. Earth Eng and Str Dyn. 4. 2014. 247–266.10.1002/eqe.2342 ↗
6. Seismic damage and performance of Palazzo Centi after L’Aquila earthquake: A paradigmatic case study of effectiveness of mechanical steel ties10.1016/j.engfailanal.2013.09.011 ↗
7. The retrofitting of historical buildings with insufficient seismic resistance using conventional and non-conventional techniques10.1016/j.engfailanal.2019.01.031 ↗
8. Comparative experimental analysis on the in-plane shear performance of brick masonry walls strengthened with different fiber reinforced materials10.1016/j.conbuildmat.2020.120387 ↗
9. Cattari · 2008
10. Upper bound analysis of meso-mechanical spandrels models for the push-over analysis of 2D masonry frames10.1016/j.engstruct.2009.06.015 ↗
11. Experimental cyclic testing of URM pier-spandrel substructure10.1061/(ASCE)ST.1943-541X.0001650 ↗
12. Two-story perforated URM wall subjected to cyclic in-plane loading10.1061/(ASCE)ST.1943-541X.0002021 ↗
13. Experimental investigation on the in-plane seismic performance of damaged walls repaired with grout-injected ferrocement overlay10.1016/j.conbuildmat.2021.122565 ↗
14. Tomazevic · 199910.1142/p055 ↗
15. Spandrel panels in masonry buildings: Effectiveness of the diagonal strut model within the equivalent frame model10.1016/j.istruc.2020.07.001 ↗
16. Quasi-static cyclic tests on masonry spandrels10.1193/1.4000063 ↗
17. Review of experimental cyclic tests on unreinforced and strengthened masonry spandrels and numerical modelling of their cyclic behavior10.1016/j.engstruct.2016.11.063 ↗
18. F. Graziotti, G. Magenes, A. Penna. Experimental cyclic behavior of stone masonry spandrels. Proceedings of 15th World Cong on Earth Eng, WCEE, Lisbon, Portugal. 2012.
19. Calderoni · 2008
20. B. Calderoni, E.A. Cordasco, P. Lenza, G. Pacella. Experimental tests for the evaluation of shear strength of spandrels in ordinary masonry. Proceedings of the 9th Int Mas Conf. Guimaraes. Portugal. 2014.
21. Nonlinear behavior of a masonry subassemblage before and after strengthening with inorganic matrix-grid composites10.1061/(ASCE)CC.1943-5614.0000203 ↗
22. FRP-reinforced masonry spandrels: Experimental campaign on reduced-scale specimens10.1016/j.conbuildmat.2020.119965 ↗
23. EN 1996-1-1. 2005. Eurocode 6. Design of masonry structures – Part 1-1: General rules for reinforced and unreinforced masonry structures. Brussels. Belgium.
24. ASTM E 519M-15. 2015. Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages. ASTM International, West Conshohocken, PA.
25. H. Krawinkler. Possibilities and limitations of scale-model testing in earthquake engineering. Proc. Of the 2nd US national Conf. on Earth Eng. Stanford, California. 1979.
26. Dynamic modelling of masonry buildings: storey mechanisms model as a simple alternative10.1002/eqe.4290150606 ↗
27. Italian Building Code 2018 (IBC18). D.M. 17/01/2018. Technical code for constructions. Ministry of Transportation and Infrastructures. Italy. (in Italian).
28. B. Ortolani, A. Vignoli. Comportamento sismico dei pannelli di fascia in muratura: prove sperimentali. Proc of 3rd Wonder Masonry Conf. Florence, Italy. 2012. (in italian).
29. A simplified theoretical model for the evaluation of structural behavior of masonry spandrels10.1504/IJMSI.2011.041934 ↗
30. EN 1998-3 2005. Eurocode 8: Design of structures for earthquake resistance – Part 3: Assessment and retrofitting of buildings. CEN (European Committee for Standardization). Brussels. Belgium.
31. Italian Seismic Recommendations n.7/2019. Instruction for the use of the Technical Code for Construction published by DM 2018. Ministry of Infrastructure and Transportation. Italy. (in Italian).
32. EQ Asses. Part C – Unreinforced masonry buildings. The seismic assessment of existing buildings. Technical Guidelines for Engineering Assessment. 2017. New Zealand.
33. ATC-FEMA306. Evaluation of earthquake damaged concrete and masonry wall buildings – basic procedures manual. Washington, D.C. 1999.