Effect of grout conditions and tendon location on corrosion pattern in PS tendon in grout
Source abstract
Abstract
Abstract Pre-stressed Concrete (PSC) has various engineering advantages like reduction of dead load, enhancement of shear strength, and reducing crack, however tendon corrosion in grout caused by deficient grout and intrusion of chlorides causes a tendon break and the related structural problems. It is important to understand the corrosion pattern varying with grout properties and placement conditions. In the work, TG (Tendon-Grout) systems are prepared considering grout quality, bleeding, tendon location, and crack width. In order to evaluate corrosion pattern in TG systems in a short period, ICM (Impressed Current Method) is adopted for corrosion acceleration for 2 and 4 days of duration. For two types of grout (conventional one and improved grout with reduced water to cement ratio and silica fume), corrosion current and its amounts are evaluated for various conditions. In the TG system with crack, corrosion greatly increases with extension of test duration for both types of grout since crack width on grout is a main channel for ion intrusion. In spite of crack effect, improved grout has better resistance to corrosion considering crack and bleeding condition. When TG system has eccentricity of tendon with small cover depth, no significant differences between conventional and improved grout are measured since cover depth is too small to protect chlorides from outside. Various effects like bleeding, crack, tendon location, and grout quality are discussed in the work. The improved properties in IG like porosity, strength, absorption ratio, and expansion rate are also investigated.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Concrete and Cement Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Corrosion propagation of prestressing steel strands in concrete subject to chloride attack10.1016/j.conbuildmat.2011.04.011 ↗
2. Enhanced modeling of moisture equilibrium and transport in cementitious materials under arbitrary temperature and relative humidity history10.1016/j.cemconres.2006.11.015 ↗
3. Japan Society of Civil Engineering (JSCE), Standard Specification for Concrete Structures-Design JSCE Guidelines for Concrete 15, Tokyo, Japan, 2013.
4. An estimation of the diffusivity of silica fume concrete
5. Broomfield · 1997 · 1
6. A smart steel strand for the evaluation of prestress loss distribution in post tensioned concrete structures10.1177/1045389X09347021 ↗
7. Reliability evaluation of a PSC highway bridge based on resistance capacity degradation due to a corrosive environment10.3390/app6120423 ↗
8. A global model for corrosion-induced cracking in prestressed concrete structures10.1016/j.engfailanal.2016.01.013 ↗
9. Corrosion of prestressing steels and its mitigation
10. Long-term monitoring of reinforcement corrosion in concrete using ground penetrating radar10.1016/j.corsci.2016.11.003 ↗
11. Corrosion and strength behaviors in prestressed tendon under various tensile stress and impressed current conditions
12. K. Lau, Corrosion of post-tensioned tendons with deficient grout, Final report, Florida Department of Transportation Research Center, BDV29-977-04, 2016, p. 202.
13. Permeh · 2015
14. Powers · 1999
15. Corrosion behavior of steel reinforcement in concrete exposed to composite chloride–sulfate environment10.1016/j.conbuildmat.2014.09.026 ↗
16. S.K. Lee, J. Zielske, An FHWA special study: post-tensioning tendon grout chloride thresholds, Federal Highwat Administration, FHWA-HRT-14-039, 2014.
17. Effect of milled glass fibers on corrosion resistance of PSC grout mortar
18. Corrosion testing of grout for posttensioning ducts and stay cables10.1061/(ASCE)0733-9445(2000)126:2(163) ↗
19. Approach to determine corrosion propensity on post-tensioned tendons with deficient grout10.4236/ojce.2013.33022 ↗
20. Assessment of the durability of grout submitted to accelerated carbonation test10.1016/j.conbuildmat.2017.10.111 ↗
21. Estimation of the permeability of silica fume cement concrete10.1016/j.conbuildmat.2009.08.033 ↗
22. Nondestructive corrosion detection in RC through integrated heat induction and IR thermography10.1007/s10921-012-0133-0 ↗
23. S. Sakurada, H. Irie, Y. Yoshida, Development of reinforced concrete corrosion amount presumption method by ultrasonic method. In: Proceedings of the 17th World Conference on Nondestructive Testing 2008, Shanghai, China, 2008, pp. 1–6.
24. Non destructive technique for steel corrosion detection using heat induction and IR thermography
25. PCI, Precase/Prestressed Concrete Institute, Precast Prestressed Concrete Bridge Design Manual, MNL-133-97, Chicago, IL 60606-6938, 1997.
26. Neville · 1995
27. Maekawa · 2009