Assessment of damaged timber structures using proof load test – Experience from case studies
Source abstract
Abstract
Abstract In this paper assessment of damaged timber structures using proof load test is given, which is mandatory according to Macedonian standards. Two types of structures were analyzed in the paper: Glued laminated timber structure, Cambered beam span of L = 24.00 m and Glued Laminated pedestrian timber bridge, two-hinged arch, span of L = 26.00 m plus two simple supported beams span of L = 12.5 m each. The results were also used for reliability verification to define partial safety factor for material for ultimate limit state and serviceability limit state, according to Eurocodes EN1990 and EN1995.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wood Treatment and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (13)
Show source-provided references
1. MKS U.C9.300/1984-Design of glue laminated timber structures, Technical requirements and Assessment of new and damaged structures.
2. MKS EN1995-1-1:2012 (EN1995-1-1:2004) Design of timber structures Part 1-1: General-Common rules and rules for building, ISRM Skopje, R. Macedonia.
3. SAMCO Final Report 2006, F08a Guideline for the Assessment of Existing Structures, Dir. u. Prof. Dr. W. Rucker, Dipl.-ing. F. Hille, Dipl. -Ing. R. Rohrmann, Federal Institute of Materials Research and Testing (BAM), Division VII.2 Buildings and Structures, Unter den Eichen 87, 12205 Berlin, Germany.
4. ISO 13822 “Bases for design of structures – Assessment of existing structures”, 2010.
5. K. Gramatikov, “Report on initial analysis for the state of stresses and deflections in the roof structure for the Coca- Cola section”, Brewery Skopje, 1996 (in Macedonian).
6. Kiril Gramatikov, Experimental Testing and Assessment of the Bearing Capacity of Glu–Lam Timber Structure of COCA–COLA Section at Skopje Brewery”, Report Faculty of Civil Engineering, 2002 (in Macedonian language).
7. S. Atanasovski, K. Gramatikov “Assessment of the bearing capacity of glulam timber bridge in Struga”, Report Faculty of Civil Engineering Faculty 2003 (in Macedonian language).
8. MKS EN1990:2012 (EN1990:2002) Basis of structural design, ISRM Skopje, R. Macedonia.
9. Joint Committee on Structural Safety, Probabilistic Model Code, 12th draft version 2000, internet version http://www.jcss.byg.dtu.dk, 2014.
10. Joint committee on Structural Safety, CodeCal, Reliability Based Code Calibration program updated 12 June 2013, internet version: http://www.jcss.byg.dtu.dk, 2014.
11. SOFiSTiK version 2012, SOFiSTiK AG-Nuremberg.
12. Dr. Alpo Ranta-Maunus, research professor VTT Technical Research Centre of Finland, Espoo, Finland “Relation of the-oretical structural reliability to safety and safety factors of timber structures”, 10. Internationales Holzbau-Forum, 2004.
13. MKS EN1995-2:2012 (EN1995-2:2004) Design of timber structures Part 2: Bridges, ISRM Skopje, R. Macedonia.