Bearing capacity diagnosis of Santiago church (Jerez de la Frontera, Spain)
Source abstract
Abstract
Abstract The aim of this research has been to determine the causes of the damages located in Santiago church (Jerez de la Frontera, Spain), such as the collapse of the pillars, the wall and vault fissures and others, which have occurred over its five hundred year existence. The most significant aspects of the investigation works performed are related to the use of combined non-destructive techniques, such as the use of georadar with ultrasounds to detect voids inside pillars and main walls, videoscope, thermograph systems, accelerator and other seismic techniques, reducing up to 20% the excavations and unnecessary bore holes in order to know the composition and heterogeneities of the elements. In addition, by using these techniques, the deformation module E – dynamic and static – at different heights in pillars, as well as the bearing capacity could be obtained, not only among the pillars, but also at the bottom, central and upper parts of each pillar. An important goal of the investigation was to determine the extent of the reinforcement works developed in 1961, checking geometric features and conservation status of concrete elements. From all the data collected, the origin of the existing damages and pathologies can be set out, and hence, a building restoration can be adequately carried out.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Building materials and conservation · Masonry and Concrete Structural Analysis · 3D Surveying and Cultural Heritage
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Archives of Santiago´s church and Jerez´s Bishop.
2. Dynamic and static moduli10.1029/GL008i001p00039 ↗
3. Relation between static and dynamic Young moduli for rocks10.1016/0148-9062(88)90987-4 ↗
4. Heyman, Jacques. El esqueleto de Piedra. Mecanica de la arquitectura de fábrica CEHOPU Madrid, 1999, 1995; ISBN: 84-89977-73-9.
5. Francisco Jurado Jiménez. Tecnología Previa A La Restauración De Edificios Históricos. Informes de la Construcción. Consejo Superior de Investigaciones Científicas. vol. 50, no. 460, marzo/abril 1999. ISSN: 0020-0883.10.3989/ic.1999.v50.i460.835 ↗
6. ASTM E494-95. Standard practice for measuring ultrasonic velocity in materials; 2001.
7. Gere James M. “Timoshenko Resistencia De Materiales” 5th ed.Editorial: Paraninfo; 2002. ISBN: 8497320654, 13: 9788497320658.
8. Maierhofer Ch, Wendrich A, Köpp Ch. ONSITEFORMASONRY – A European Research Project: on-site investigation techniques for the structural evaluation of historic masonry DGZfP In: International symposium non-destructive testing in civil engineering (NDT-CE) in Berlin, Germany, September 16–19, 2003, proceedings on BB 85-CD, V70, Berlin; 2003.
9. Young · 2004
10. Barrios J, Barrios A. “Caracterización de los materiales que conforman la cúpula de la Sacristía Mayor de la S.I. Catedral de Sevilla”. Materiales de construcción. Csic. Madrid 2004; p. 79–88. ISSN: 0465-2746.10.3989/mc.2004.v54.i273.225 ↗
11. Differences between static and dynamic elastic moduli of a typical seismogenic rock10.1111/j.1365-246X.2004.02213.x ↗
12. Avseth · 2005
13. Eaton · 2006
14. Bodo Lehmann. Seismic traveltime tomography for engineering and exploration applications. Houten, The Netherlands: EAGE Publications; 2007. 1: p. 273. ISBN: 978-90-73781-41-2.
15. The Golden Tower: characterization of its foundations and the underlying soil10.1016/j.conbuildmat.2005.12.017 ↗
16. The analysis of masonry architecture: a historical approach10.3763/asre.2008.5136 ↗