journal article·2009-02Open access

Impact of air intrusion on the wind uplift performance of fully bonded roofing assemblies

A. Baskaran, S. Molleti

Abstract

Abstract Wind performance investigation is critical in the design of durable roofing assemblies. In North America, mainly two types of low slope roofs, conventional and inverted, are in practice depending on the placement of the membrane in the assembly. As part of the conventional low-sloped roofs, in a fully bonded assembly (FBA) the insulation is mechanically attached and waterproof membrane is bonded to the insulation using adhesives. Recent field investigations of roof failures after major hurricanes indicated that FBA are susceptible to high wind events. To understand the response of the FBA under dynamic environment, an extensive experimental study has been carried out by the SIGDERS – Special Interest Group for Dynamic Evaluation of Roofing Systems , at the National Research Council. The present study focuses on the impact of air intrusion on wind uplift performance of these assemblies. Airflow control is usually achieved by including a barrier/retarder in the roofing assembly. Assembly with barrier improved the wind uplift rating by two fold when compared to an assembly without barrier. Use of staggered insulation arrangement can provide similar air retarding effect as a barrier and can therefore sustain similar wind uplift pressures compared to an assembly with barrier.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wind and Air Flow Studies · Structural Analysis of Composite Materials · Masonry and Concrete Structural Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. American Society of Civil Engineering. Minimum design loads for building and other structures. SEI/ASCE 7-04, New York, USA, 10017-2398; 2005.
2. Baskaran A, Paroli RM, Booth RJ. Wind performance evaluation procedures for roofing systems current status and future trends. In: Proceedings of the Fifth International Conference on Building Envelope Systems and Technology, Bath, UK, 1997, p. 37–52.
3. Baskaran A, Lei W. A new facility for dynamic wind performance evaluation of roofing systems. In: Proceedings of the fourth international symposium on roofing technology, NRCA/NIST, Washington, DC, USA, 1997, p. 168 –79.
4. Dynamic evaluation of thermoplastic roofing systems for wind performance10.1061/(ASCE)1076-0431(1999)5:1(16) ↗
5. A new dynamic wind load cycle to evaluate flexible membrane roofs10.1520/JTE12223J ↗
6. Baskaran A, Ladubec C, Sexton M. SIGDERS Wind uplift resistance data on fully bonded single ply roofing systems – Effect of vapor/air/ barrier. Research Report, Institute for Research in Construction, National Research Council Canada, IRC -RR # 115; 2002.
7. Baskaran A, Smith TL. A Guide for the wind design of mechanically attached flexible membrane roofs. National Research Council Canada, Ottawa, Ontario; 2005, Canada K1A 0R6.
8. Wind performance evaluation of fully bonded roofing assemblies10.1016/j.conbuildmat.2006.08.011 ↗
9. Baskaran A, Molleti S, Booth RJ. Understanding air barriers in mechanically attached low slope roofing assemblies for wind uplift. in: Proceedings of the 3rd international building physics/science conference, August 27th–31st. Montreal, Canada; 2006.
10. Wind load resistance of modified bituminous roofing systems10.1016/S0950-0618(98)00025-7 ↗
11. CSA Number A123.21-04. Standard test method for the dynamic wind uplift resistance of mechanically attached membrane-roofing systems, Canadian Standards Association, Canada. (); 2004.
12. Molleti S, Baskaran A, Ko S. Development of a new test method for air intrusion quantification of roofing assemblies. J Test Eval 2008;36(3):in press.10.1520/JTE100983 ↗
13. National Roofing Contractors Association. Hurricane Charley: A Preliminary Report. Professional Roofing Magazine, NRCA, October; 2004.
14. National Research Council Canada. National Building Code of Canada. Ottawa, Ontario; 2005, Canada K1A 0R6.
15. ANSI/SPRI. Standard field test procedure for determining the mechanical uplift resistance of insulation adhesives over various substrates. American National Standards Institue/ Single-Ply Roofing Institue,IA-1; 2005.
16. RICOWI, Inc. Hurricanes Charley and Ivan Wind Investigation Report. Roofing Committee on Weather Issues Inc., McDonough, Georgia, March; 2006, p. 286.
17. Bomberg M, Kumaran MK. A test method to determine air flow resistance of exterior membranes and sheathing. Building Research Note No. 227, National Research Council, Ottawa, April;1985.