Assessment of concrete columns repaired with fiber reinforced mortar through damage indexes and numerical model
Source abstract
Abstract
Abstract Following previous research, the current paper describes the results of an experimental program concerning the repair of reinforced concrete columns by fiber reinforced thixotropic mortar, preformed to analyze and quantify the influence of casting deficiencies on the behavior of the repaired structural element. Ten columns (section scale 1:2) were designed according to the requirements of ductility orientated codes’ design with variables the percentages of initial construction damages and the confinement ratio (0.075:0.15). All were tested in axial compression with repeated cycles up to failure. For comparison reasons, one column of each confinement category, yet healthy, was constructed and tested as reference specimen. A numerical study was conducted for further investigation of the behavior of the thixotropic mortar as repair material and a new empirical model is propose to predict the behavior of the repaired element. The results indicate that: (a) surpassing a damage limit, buckling of steel occurs but is not included in the model so the post-peak behavior of suitably repaired elements is lower than predicted, (b) confinement ratio is primer mechanism that acts favorably on the elements’ capacity, (c) the proposed model comes in remarkable agreement with the experimental results, making it a safe assessment method with the use of damage indexes proposed without expertise non-destructive methods.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Achillopoulou DV, Karabinis AI, repaired concrete columns with fiber reinforced thixotropic mortar. Exp FEA Approach Comput Concrete; 2014 [in press].10.12989/cac.2015.15.1.073 ↗
2. Saand A, Ismail M, Sumadi SR, Afridi MUK. Behaviour of pre-damaged reinforced concrete beams repaired with polymer-modified mortar. In: Materials, experimentation, maintenance and rehabilitation – proceedings of the 10th east Asia-Pacific conference on structural engineering and construction, EASEC; 2010 p. 27–32.
3. European Standard EN. Eurocode 8 Design of structures for earthquake resistance, Part 3: Assessment and retrofitting of Buildings; 2005.
4. Organisation of Seismic Design and Protection. Greek Retrofit Code Attuned to EN 1998/3; 2012 [In Greek].
5. American Concrete Institute. Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary, ACI-318R-08 Building Code; 2008.
6. Achillopoulou DV, Karabinis AI. Initial construction damage effect on the behaviour of reinforced concrete columns. In: Proceedings of 2nd European conference on earthquake engineering and seismology, Istanbul; 2014.
7. Investigation of shear transfer mechanisms in repaired damaged concrete columns strengthened with RC jackets10.12989/sem.2013.47.4.575 ↗
8. Achillopoulou DV, Rousakis TC, Karabinis IA. Force transfer between existing concrete columns with reinforced concrete jackets subjected to pseudoseismic axial loading. In: Proceeding of 15th WCEE, Lisbon; 2012.
9. Types and causes of cracking in concrete structures10.1533/9781845697037.1.57 ↗
10. Types of damage in concrete structures10.1533/9781845697037.1.32 ↗
11. Capacity of RC joints subjected to early-age cyclic loading10.1080/13632460009350380 ↗
12. Effectiveness of RC beam-column connection repair using epoxy resin injections10.1080/13632469809350320 ↗
13. Stress and strain state of concrete during freezing and thawing cycles10.1016/S0008-8846(02)00785-8 ↗
14. Simulating ice-sloping structure interactions with the cohesive element method10.1115/1.4026959 ↗
15. The effect of corrosion on shear behavior of reinforced self-consolidating concrete beams10.1016/j.engstruct.2014.07.044 ↗
16. Fatigue life prediction for aging RC beams considering corrosive environments10.1016/j.engstruct.2014.07.039 ↗
17. Durability of mixtures containing calcium nitrite based corrosion inhibitor10.1016/j.cemconcomp.2004.02.016 ↗
18. Testing of full-scale RC frame under simulated fire following earthquake10.1260/2040-2317.5.3.215 ↗
19. EN 1504: European Standard: Products and systems for the protection and repair of concrete structures – definitions, requirements, quality control and evaluation of conformity, European Committee for Standardization; 2013.
20. BASF technical guides for Emaco S88C T Shrinkage compensated, polymer fiber reinforced, thixotropic repair mortar.
21. EN 206-1: European Standard: Concrete – Part 1: specification, performance, production and conformity. European Committee for Standardization; 2000.
22. ACI 309R-06: Guide for consolidation of concrete. ACI Committee 309. American Concrete Institute; 2006.