journal article·2007-11Open access

Defects of non-loadbearing masonry walls due to partial basal supports

R. Da Silva Vicente, J.A.R. Mendes da Silva

Abstract

Abstract The attempts to reduce heat transmission heterogeneity all over the external surface of building envelopes include several recommendations about external protection of concrete structures with thin clay brick walls. This procedure was extensively adopted in Portugal during the last ten years in consequence of the new national thermal code. This practice has generated several defects in consequence of the insufficient technological knowledge in this domain. This work analyses some of those defects adopting an experimental and a numerical approach, using the traditional Portuguese clay brick with a high percentage of horizontal voids.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Hygrothermal properties of building materials · Building Energy and Comfort Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Vicente R. Pathology of masonry enclosure walls. Mechanical behaviour of enclosure walls with external thermal bridge correction, MSc thesis in Civil Engineering, University of Coimbra, 2002 [in Portuguese].
2. Silva J, Vicente R. Damages and defects of masonry enclosure walls (enclosure wall instability and cracking due to correction of thermal bridges), In: The 7th international conference on inspection, appraisal, repairs & maintenance of buildings & structures, 11–13 September, 2001.
3. Tubi Norberto – La Realizzazione di Murature in Laterizio, Roma. Andil, Sezione Murature, 1986.
4. Duque V, Tadeu A, Silva J, Meliço S. Illness related to thermal pathologies in buildings. In: International conference on implementation of safety and health on construction sites, CIB W99, Lisboa, Setembro 1996.
5. Garratt J, Nowak F. Tackling condensation: a guide to the causes of, and remedies for, surface condensation and mould in traditional housing, BRE Report, Garston, 1991.
6. Portugal – laws, decrees, etc. Portuguese Thermal Code (Regulamento das Caracterı´sticas de Comportamento Térmico dos Edifı´cios. Dec.-Lei n° 40/90 de 6 de Fevereiro de 1990).
7. The new Portuguese building thermal regulations: a passive and low energy approach, PLEA 91 (Passive and low energy architecture congress), Sevilha
8. Hendry AW, Sinha BP, Davies SR. Design of masonry structures. Load bearing brickwork design, 3rd ed., 1997.
9. Silva J, Abrantes V, Vicente R, Precocious degradation of enclosure walls with external thermal bridge correction. Case studies, National Congress on Construction, IST, Lisbon, December, 2001 [in portuguese].
10. CEN, Eurocode 6, Design of masonry structures – Part 1-1: General rules for buildings – Rules for reinforced and unreinforced masonry. CEN, prENV 1996-1-1, 1995.
11. BSI, BS 5628 – code of practice for use of masonry. Part 1: Structural use of unreinforced masonry, BSI, London, 1992.
12. CSTB (Groupe de Coordination des Textes Techniques) – DTU 20.1 (référence AFNOR DTU P10-202) – Parois et murs en maçonnerie de petits éléments. Cahier CSTB 2024, livraison 262, CSTB, Paris, Septembre 1985.
13. CIB – W23 – International recommendations for design and erection of unreinforced and reinforced masonry structures with an appendix on recommendations for seismic design of unreinforced, confined and reinforced masonry structures. Publication 94. CIB, Rotterdam, 1987.
14. John H. Matthys, editor, TMS – The Masonry Society; ACI, American Concrete Institute; CMR – Council for Masonry Research – Masonry Designers’ Guide. 1st ed., 1993, Boulder (CO), 1993.