Flexural strength of low density blockwork
Source abstract
Abstract
The characteristic flexural strength of low density Aircrete wallettes (2.8 and 2 N/mm 2) incorporating both conventional and thin layer mortar is verified. The wallettes are tested in accordance with BS EN 1052-2. The flexural strength of Aircrete wallettes is derived from the strength of small specimens tested to destruction under four-point loading. The strengths of the wallettes are high with impressive repeatability with the maximum strength being reached for thin layer wallettes within 7 days curing time. In general the strengths of both conventional mortar and thin layer mortar wallettes compare favourably to values reported in BS 5628. © 2005 Taylor & Francis Group.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Innovations in Concrete and Construction Materials · Structural Analysis of Composite Materials · Recycling and utilization of industrial and municipal waste in materials production
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. H+H Celcon Ltd., Celcon House, Ightham, Sevenoaks, Kent, TN15 9HZ. [accessed 24.11.11].
2. The UK Aircrete Association. Code of best practice for the use of aircrete products; 2011. .
3. Ahmed A, Fried A, Roberts JJ, Limbachoya M. Advantages and implications of high performance low density aircrete products for the UK Construction Industry. In: 13th international brick and block masonry conference (IBBMaC), Amsterdam, Netherlands; 2004.
4. Bright N, Ahmed A. Concentrated loads on aircrete thin joint blockwork. In: 14th international brick and block masonry conference (IBBMaC), Sydney, Australia; 2008.
5. Dubral W. YTONG AG, Munich, Germany. In: Wittmann editor. Advances in autoclaved aerated concrete. Rotterdam: ©Balkema; 1992. ISBN 90 5410 086 9.
6. Mitsuda T, Kiribayashi T. Influence of hydrothermal processing on the properties of autoclaved aerated concrete. In: Wittmann editor. Advances in autoclaved aerated concrete. Rotterdam: ©Balkema; 1992. ISBN 90 5410 086 9.
7. Callister Jr W. Department of Metallurgical Engineering, The University of Utah, Materials Science and Engineering – An Introduction. Seventh ed., John Wiley and Sons, Inc.; 2006. ISBN 9780471736967.
8. Ungkoon et al. A preliminary study of hydrothermal performance of autoclaved aerated concrete blocks under hot humid climate of Thailand. In: International conference “passive and low energy cooling for the built environment”. Greece: Santorini; 2005.
9. Thermalite, Hanson HeidelBerg Cement Group. [accessed 18.11.11].
10. Design for homes. Application of aircrete blocks. [accessed 18.11.11].
11. Lippe K. YTONG AG, R + D Centre, Schrobenhausen, Germany, The effect of moisture on the thermal conductivity of AAC. In: Wittmann editor. Advances in autoclaved aerated concrete. Rotterdam: ©Balkema; 1992. ISBN 90 5410 086 9.
12. Liu C, Wang J. Suzhou Concrete and Cement Products Research Institute, China. An experimental study on thermal transmission properties of aerated concrete composite panels. In: Wittmann editor. Advances in autoclaved aerated concrete. Rotterdam: ©Balkema; 1992. ISBN 90 5410 086 9.
13. Tarmac Building products, Lightweight Aircrete Blocks. [accessed 18.11.11].
14. Quan Y, Nianxiang Y. Applications of autoclaved aerated concrete block in new energy-saving building structure. In: Electric technology and civil engineering (ICETCE) Conference. Lushan, China; 2011. p. 1066–9.10.1109/ICETCE.2011.5775764 ↗
15. Yuplng Z, Dedong L, Guokuang S. Investigation into the carbonation of autoclaved aerated concrete. In: 8th international congress on the chemistry of cement. vol 5; 1996. p. 93–8.
16. Wittman FH. Autoclaved Aerated Concrete: Properties, Testing and Design, RILEM Recommended Practice. RILEM technical committees 78 – MCA and 51 – ALC; 1993a.
17. Tada S. Texte, Inc. and Nihon University, Japan. Pore structure and moisture characteristics of porous inorganic binding materials. In: Wittmann editor. Advances in autoclaved aerated concrete. Rotterdam: ©Balkema; 1992. ISBN 90 5410 086 9.
18. Jacobs F, Mayer G. Institute for Building Materials, ETH Zurich, Switzerland, Porosity and Permeability of autoclaved aerated concrete. In: Wittmann editor. Advances in autoclaved aerated concrete. ©Balkema, Rotterdam, 1992. ISBN 90 5410 086 9.
19. Schober G, Hebel AG, Emmering. Germany, Effect of size distribution of air pores in AAC on compressive strength. In: Wittmann editor. Advances in autoclaved aerated concrete. Rotterdam: ©Balkema; 1992. ISBN 90 5410 086 9.
20. British Standards a, BS 5628: Part 1: 1992 – Structural use of unreinforced masonry.
21. British Standards b, BS EN 1052: Part 2: 1999 – determination of flexural strength. Now incorporated into Eurocode 6.