The impregnation of the exterior surface of a masonry wall with a water repellent is a common intervention in (historic) building renovation and maintenance. Such treatments, whilst degrading at the surface with time under influence of ultra violet light, remain effective below the surface several decades after their application. During renovation works of masonry previously treated with a water repellent, the question arises whether it is necessary to repeat the hydrophobic treatment of the entire masonry after repointing. Opposing opinions exist with this regard, but no research clearly supporting one or the other. This research investigates for the first time the effect of hydrophobic treatment when applied on previously treated and repointed masonry walls. Small masonry walls were subjected to rain periods in the laboratory and their water uptake and drying behaviour were studied. Moreover, this laboratory research was followed by 30 months of outdoor exposition of the masonry specimens. The following cases were considered: (1) wall treated with water repellent, (2) wall treated with water repellent, followed by repointing but without new water repellent treatment, (3) wall treated with water repellent, followed by repointing and retreatment. This was done for three different types of pointing mortar: ordinary Portland cement and natural hydraulic lime with standard sand, and natural hydraulic lime with sand with one grain size. The results show that, after prolonged rain periods, the water uptake by repointed but not retreated masonry is comparable to that of untreated, non-hydrophobic masonry, whereas drying is considerably slower. This leads to a high saturation degree in repointed but not retreated masonry, which, in turn, increases the risk of damage to the masonry by e.g. frost. Therefore, retreating repointed hydrophobic masonry should definitively be considered.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Building materials and conservation · Hygrothermal properties of building materials · Conservation Techniques and Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Damage development to treated brick masonry in a long-term salt crystallisation test10.1016/j.conbuildmat.2004.02.006 ↗
2. R.P.J. van Hees, J.A.G. Koek, H. de Clercq, E. de Witte, L. Binda, G. Baronio. Evaluation of the performance of surface treatments for the conservation of brick masonry. In: J. Riederer, ed., Proceedings of the 8th International Congress on Deterioration and Conservation of Stone, Berlin, 1695–1715, 1996.
3. R.P.J. van Hees, J.A.G. Koek, H. de Clercq, E. de Witte, L. Binda, E.D. Ferrieri, E. Carraro. The assessment of the performance of surface treatments in the field. Results of 60 case studies confronted with lab results. In: R.P.J. van Hees, ed., Evaluation of the performance of surface treatments of historic brick masonry. EC Research report 7:733–767, 1998.
4. A. Pien. Hydrofugation de surface des maconneries, In: G. Félix, ed., Proceedings of the 5th International Congress on Deterioration and Conservation of Stone, Lausanne, 909–913, 1985.
5. Durability of the hydrophobic treatment on brick and mortar10.1016/j.buildenv.2021.107994 ↗
6. transport in mortar joint
7. transfer through mortar joints: A sharp-front analysis10.1016/j.cemconres.2012.05.004 ↗
8. performance of a massive masonry wall: How do the mortar joints influence the moisture flux ?10.1016/j.conbuildmat.2012.12.024 ↗
9. Liquid moisture transport in combined ceramic brick and natural hydraulic lime mortar samples: Does the hygric interface resistance dominate the moisture transport ?10.1177/1744259119857762 ↗
10. R.P.J. van Hees, S., Naldini, L.J.A.G. van der Klugt. Maintenance of pointing in historic buildings: Decay and replacement. Final report, EU contract ENV4-CT98–706, 2001.
11. K. van Zundert, R. van Zwet. Evaluatie verschillende producten als alternatief voor Wapex in wateropname en droogexperimenten in het laboratorium. TNO, Delft, TNO report 2019-R10244, 2019.
12. NEN-EN 15801:2009. Conservation of cultural property - Test methods - Determination of water absorption by capillarity.
13. NEN-EN 772–11:2011. Methods of test for masonry units - Part 11: Determination of water absorption of aggregate concrete, autoclaved aerated concrete, manufactured stone and natural stone masonry units due to capillary action and the initial rate of water absorption of clay masonry units.
14. Absorption of water by immersion under vacuum
15. CUR Recommendation 61:2013. Het voegen en hydrofoberen van metselwerk.
16. NEN 2872:1989. Beproeving van steenachtige materialen. Bepaling van de vorstbestandheid. Eenzijdige bevriezing in zoetwatermilieu.