Quantitative assessment of corrosion in reinforced concrete structure using low-attenuation ultrasonic modes integrated with Bayesian updating strategy
Source abstract
Abstract
To achieve a balance between accuracy and efficiency in the corrosion assessment of reinforced concrete structures, this paper proposes an approach that integrates guided waves (GWs) with a Bayesian modification strategy for quantifying corrosion. The selection of high-order longitudinal GW modes with low attenuation minimizes scattering interference, making them efficient candidates for corrosion detection. A new dimensionless damage index (DI), more suitable for long-term monitoring, is developed based on the observed attenuation behavior of GWs during the corrosion process. Previous studies on GW-based corrosion testing have primarily focused on specific laboratory systems; however, directly applying their corresponding models (regression relationship between DI and corrosive damage features) in field applications often leads to significant deviations. In this study, we consider the qualification model established in the laboratory as prior knowledge that indicates general commonalities between DI and corrosive wastage. By incorporating sparse field data through Bayesian updating, our proposed method is promising to quantify corrosion in on-site target structures using the resulting posterior model. Proof-of-concept is demonstrated using collected data from continuous monitoring experiments conducted on concrete samples undergoing accelerated corrosion; these results illustrate the feasibility and potential practicality of our proposed method.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Geophysical Methods and Applications · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Durability evaluation of concrete structure based on reinforcement corrosion
2. Evaluation and Bayesian dynamic prediction of deterioration of structural performance10.1080/15732470701478503 ↗
3. Life-cycle performance, management, and optimisation of structural systems under uncertainty: accomplishments and challenges10.1080/15732471003594427 ↗
4. Half-cell potential mapping to assess repair work on RC structures10.1016/S0950-0618(00)00062-3 ↗
5. Detection of corrosion degradation using electrochemical noise (EN): review of signal processing methods for identifying corrosion forms, Corrosion Engineering
6. A review of magnetic flux leakage nondestructive testing10.3390/ma15207362 ↗
7. Vaghefi · 2013
8. Wolfson · 1987
9. Huo · 2021
10. A review of distributed optical fiber sensors for civil engineering applications10.3390/s16050748 ↗
11. Combined embedded and surface-bonded piezoelectric transducers for monitoring of concrete structures10.1016/j.ndteint.2014.03.009 ↗
12. Wave attenuation measurement technique for nondestructive evaluation of concrete10.1080/10589759.2011.606319 ↗
13. Rose · 1999
14. J.L. Rose, 2011, The upcoming revolution in ultrasonic guided waves, 7983 (2011) 798302.10.1117/12.897025 ↗
15. Ultrasonic guided wave inspection of anchor rods embedded in soil10.1007/s10921-019-0619-0 ↗
16. Novel method for the detection of onset of delamination in reinforced concrete bridge decks10.1061/(ASCE)CF.1943-5509.0001093 ↗
17. Characterization of steel-concrete interface bonding conditions using attenuation characteristics of guided waves10.1016/j.cemconcomp.2017.07.001 ↗
18. Detection and quantification of diameter reduction due to corrosion in reinforcing steel bars10.1177/1475921715578315 ↗
19. Longitudinal guided waves for monitoring chloride corrosion in reinforcing bars in concrete10.1177/1475921710365415 ↗
20. Sensitivity of longitudinal guided wave modes to pitting corrosion of rebars embedded in reinforced concrete10.1016/j.conbuildmat.2019.117855 ↗
21. C. Ma, Corrosion monitoring of rebar embedded in concrete using guided waves, Harbin Institute of Technology, Harbin, 2017.
22. B.L. Ervin, Monitoring corrosion of rebar embedded in mortar using guided ultrasonic waves, University of Illinois at Urbana-Champaign, Urbana,Illinois, 2007.
23. Guided waves for damage detection in rebar-reinforced concrete beams10.1016/j.conbuildmat.2013.05.016 ↗
24. Detection and assessment of pitting corrosion in rebars using scattering of ultrasonic guided waves10.1016/j.ndteint.2018.10.005 ↗
25. Corrosion monitoring of post-tensioned concrete structures using fractal analysis of guided ultrasonic waves10.1002/stc.1586 ↗
26. Effect of pitting corrosion on capacity of prestressing wires10.1680/macr.2007.59.2.131 ↗
27. Corrosion-Induced Cracking: Experimental Data and Predictive Models
28. Identification of Zero Effect State in Corroded RCC Structures Using Guided Waves and Embedded Piezoelectric Wafer Transducers (PWT)10.1016/j.proeng.2017.04.476 ↗
29. Jones · 1992
30. B.N. Paviakovic, M. Lowe, O. Alleyne, P. Cawley, Disperse Users's Manual:Version 2.0.11, 2001.
31. Longitudinal guided waves for monitoring corrosion in reinforced mortar10.1088/0957-0233/19/5/055702 ↗
32. Ntzoufras · 2009
33. WinBUGS (Version1.4.3)[EB/OL]. 2020. 〈https://www.mrc-bsu.cam.ac.uk/software/bugs/〉.
34. Murphy K., Mahdaviani M. Matbugs[EB/OL]. 2005. 〈https://github.com/matbugs/matbugs〉.
35. Li · 2010