Repairs of longitudinal joint separations and their performances

Dar Hao Chen

Publisher page

Abstract

Abstract Many miles of CRCP and JCP in Texas suffer distresses due to longitudinal joint separation and slab faulting. The absence or ineffectiveness of tie bars causes larger deflections of concrete slabs and pumping, ultimately resulting in lane separation, cracking and faulting of slabs. In addition to full depth repair, slot stitching, stapling, and cross stitching have been used by districts to repair longitudinal cracks and longitudinal joint separations. Field results indicated that districts have successful experiences with slot stitching and stapling to restore load transfer along longitudinal joint and provide horizontal anchorage to prevent further lane separations. Longitudinal joints that had been repaired with slot stitching did not appear to have suffered any further separation or major faulting. Houston district has utilized stapling in many projects. Some of the stapling projects last for more than 8 years. Condition survey results indicated that the performances vary significantly when different slot filler (or elastomeric) materials were used in stapling projects. Few areas showed poor performance as the filler materials had cracked, spalled, and de-bonded from the wall of the slot. In some areas, chunks of the filler material had come out of the stapling joints. The cross stitching may be used to repair cracks/separations that are fairly tight. For wider cracks/joint separations and/or faulted slabs, cross stitching is not suitable. Slot stitching with Class P concrete filler material is the most cost effective approach to repair wide longitudinal joint separations. The cost would be double if full depth repair was used instead of slot stitching to repair the wide longitudinal joint separations.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Infrastructure Maintenance and Monitoring · Geotechnical Engineering and Underground Structures · Asphalt Pavement Performance Evaluation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. American Concrete Pavement Association (ACPA). Stitching concrete pavement cracks and joints. Special report SR903P. Skokie (IL): American Concrete Pavement Association; 2001
2. Investigation of settlement on a joint concrete pavement10.1061/(ASCE)CF.1943-5509.0000050 ↗
3. Chen Dar-Hao, Fowler D, Whitney D, Won M. Results of repairs on Texas longitudinal joints and cracks. ASCE Geotechnical Special Publications. Number 218; 2011. p. 208–14.10.1061/47629(408)26 ↗
4. Effect of tie bars on the field performance of full-depth repair on concrete pavement10.1080/14680629.2011.644076 ↗
5. Gaspard K, Morvant M. Assessment of the Uretek process on Continuously Reinforced Concrete Pavement, Jointed Concrete Pavement, and Bridge Approach Slabs. Technical assistance report number 03-2TA. Louisiana Transportation Research Center. Louisiana Department of Transportation and Development; 2003.
6. Pierce L, Uhlmeyer J, Weston J. Dowel bar retrofit—do’s and don’ts. report WA-RD 576.1. Olympia (WA): Washington State Department of Transportation; 2003.
7. Soltesz S. Injected polyurethane slab jacking. Final report. SPR 306-261. Oregon Department of Transportation; 2002.
8. Stringer M, Crawford T, Fowler D, Jirsa J, Won M, Whitney D. Assessment and rehabilitation methods for longitudinal cracks and joint separations in concrete pavement. Research report 0-5444-2. Texas Department of Transportation. Austin, TX 78763-5080; 2009.