journal article·2021-10-12Open access

Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume

Yu-Chuan Tseng, Han-Sheng Chen, Szu-Yu Hsiao, Kun-Jung Hsu, Chun-Ming Chen

Materials· Volume 14· Issue 20

Abstract

The microthread neck concept has been applied to dental implants. This study investigated the pullout strength and destruction volume of orthodontic microimplants with and without the microthread neck design. Fifteen microimplants (diameter: 1.5 × 10 mm) of three types (Types A and B: without microimplant neck; Type C: with microimplant neck) were tested. The insertion torque (IT), Periotest value (PTV), horizontal pullout strength (HPS), and horizontal destruction volume (HDV) of each type were measured. Kruskal–Wallis H test and Dunn’s post-hoc comparison test were performed to compare the measured values of the three types of microimplants. The correlations of the measured values were used to perform the Spearman’s correlation coefficient analysis. The ITs of Types B (8.8 Ncm) and C (8.9 Ncm) were significantly higher than those of Type A (5.2 Ncm). Type B yielded the lowest PTV (4.1), and no statistical differences in PTV were observed among the three types. Type A had a significantly lower HPS (158.8 Ncm) than Types B (226.9 Ncm) and C (212.8 Ncm). The three types did not exhibit any significant differences in the HDV. The results of the Spearman’s correlation coefficient test revealed that HDV (ρ = 0.710) and IT (ρ = 0.813) were strongly correlated with HPS, whereas for PTV and HPS, it was not. HPS was strongly and significantly correlated with HDV. The orthodontic microimplant with a microimplant neck design did not perform better than that without a microthread in the mechanical strength test.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Orthodontics and Dentofacial Orthopedics · Additive Manufacturing and 3D Printing Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan

Division of Orthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan

Department of Dentistry, Kaohsiung Municipal Siaogang Hospital, Kaohsiung 812, Taiwan

Division of Dentistry for Child and Special Needs, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan

Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan

Division of Oral and Maxillofacial Surgery, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan

References (21)

Show source-provided references
1. The skeletal cortical anchorage using titanium microscrew implants
2. Maxillary molar intrusion with micro-implant anchorage (MIA)
3. Insertion torque and success of orthodontic mini-implants: A systematic review10.1016/j.ajodo.2012.06.013 ↗
4. In vitro evaluation of insertion and removal torques of orthodontic mini-implants10.1016/j.ijom.2010.09.013 ↗
5. Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length10.2319/121206-507.1 ↗
6. Mechanical strength of stainless steel and titanium alloy mini-implants with different diameters: An experimental laboratory study10.1186/s40510-021-00352-w ↗
7. Effect of cortical bone thickness and density on pullout strength of mini-implants: An experimental study10.1016/j.ajodo.2019.02.020 ↗
8. Insertion torque, pull-out strength and cortical bone thickness in contact with orthodontic mini-implants at different insertion angles10.1093/ejo/cjs095 ↗
9. The correlation between crestal bone resorption and implant stability during healing period using resonance frequency analysis10.1097/ID.0b013e318296583d ↗
10. Gripping and Anchoring Effects on the Mechanical Strengths of Orthodontic Microimplants10.1097/ID.0000000000000765 ↗
11. Monitoring the Changes of Material Properties at Bone-Implant Interface during the Healing Process In Vivo: A Viscoelastic Investigation
12. Relationship of implant stability and bone density derived from computerized tomography images10.1111/cid.12579 ↗
13. Effects of implant design and surface on bone regeneration and implant stability: An experimental study in the dog mandible10.1111/j.1708-8208.2001.tb00123.x ↗
14. A randomized controlled clinical trial to assess crestal bone remodeling of four different implant designs10.1111/cid.12604 ↗
15. Effects of the taper shape, dual-thread, and length on the mechanical properties of mini-implants10.2319/071808-374.1 ↗
16. The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone10.1016/j.ijom.2008.09.006 ↗
17. Computed tomographic characterization of mini-implant placement pattern and maximum anchorage force in human cadavers10.1016/j.ajodo.2010.05.024 ↗
18. Is trabecular bone related to primary stability of miniscrews?10.2319/052513-39.1 ↗
19. Factors affecting the pullout strength of cancellous bone screws10.1115/1.2796022 ↗
20. Effect of Implant Diameter on Fatigue Strength10.1097/ID.0000000000000502 ↗
21. Kim, W.H., Song, E.S., Ju, K.W., Lim, D., Han, D.W., Jung, T.G., Jeong, Y.H., Lee, J.H., and Kim, B. (2020). Mechanical Assessment of Fatigue Characteristics between Single- and Multi-Directional Cyclic Loading Modes on a Dental Implant System. Materials, 13.10.3390/ma13071545 ↗