Dimensional Accuracy Assessment of 3D-Printed Edentulous Jaw Models: A Comparative Analysis Using Three Laboratory Scanners
Source abstract
Abstract
The dimensional accuracy of 3D-printed edentulous jaw models is critical for successful prosthetic treatment outcomes. This study investigated the accuracy of 3D-printed working models of a completely edentulous jaw through comparative analysis of digital images generated by three laboratory scanners. A reference plaster model of a mandibular edentulous arch was digitized and used to produce ten resin models via digital light processing (DLP) technology. Each model was scanned using three different laboratory scanners: AutoScan-DS-EX, AutoScan-DS-EX Pro(H), and Optical 3D Scanner Vinyl. Digital comparison was performed using specialized software, evaluating the root mean square (RMS) deviation and percentage of values within an acceptable deviation range ±0.05 mm. All printed models showed significant deviations from the reference model (p < 0.05), with RMS values ranging from 109.2–139.7 µm and acceptable deviation percentages ranging from 29.34 to 32.31%. The mean precision RMS value was 66.37 µm. The mean intraclass correlation coefficient of 0.544 indicated moderate precision. Optical 3D Scanner Vinyl demonstrated the highest consistency, while AutoScan-DS-EX Pro(H) showed maximum variability. No statistically significant differences were found between scanners (p = 0.075). While the investigated scanners demonstrated reliable performance and sufficient accuracy, the additive manufacturing process introduced clinically significant deviations, highlighting the importance of verification between printed models and their digital originals before proceeding with clinical stages. Clinical practice should prioritize scanning systems with advanced software algorithms over those with superior hardware specifications alone.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Anatomy and Medical Technology · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Medical College “Y. Filaretova”, Medical University—Sofia, Yordanka Filaretova 3 Str., 1606 Sofia, Bulgaria
Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University—Sofia, Georgi Sofiiski Str., 1431 Sofia, Bulgaria
References (33)
Show source-provided references
1. A comparison of trueness and precision of 12 3D printers used in dentistry10.1038/s41405-022-00108-6 ↗
2. Czajkowska, M., Walejewska, E., Zadrożny, Ł., Wieczorek, M., Święszkowski, W., Wagner, L., Mijiritsky, E., and Markowski, J. (2020). Comparison of Dental Stone Models and Their 3D Printed Acrylic Replicas for the Accuracy and Mechanical Properties. Materials, 13.10.3390/ma13184066 ↗
3. Etemad-Shahidi, Y., Qallandar, O.B., Evenden, J., Alifui-Segbaya, F., and Ahmed, K.E. (2020). Accuracy of 3-Dimensionally Printed Full-Arch Dental Models: A Systematic Review. J. Clin. Med., 9.10.3390/jcm9103357 ↗
4. Effects of remeshing algorithms on trueness of fit when used to compress.stl files for dental models: A narrative review10.1016/j.jdent.2023.104531 ↗
5. Effect of internal structures on the accuracy of 3D printed full-arch dentition preparation models in different printing systems10.4047/jap.2023.15.3.145 ↗
6. Effect of additive manufacturing process and storage condition on the dimensional accuracy and stability of 3D-printed dental casts10.1016/j.prosdent.2021.02.028 ↗
7. Evaluation of dimensional accuracy and degree of polymerization of stereolithography photopolymer resin under different postpolymerization conditions: An in vitro study10.1016/j.prosdent.2020.02.023 ↗
8. Shin, S.H., Lim, J.H., Kang, Y.J., Kim, J.H., Shim, J.S., and Kim, J.E. (2020). Evaluation of the 3D Printing Accuracy of a Dental Model According to Its Internal Structure and Cross-Arch Plate Design: An In Vitro Study. Materials, 13.10.3390/ma13235433 ↗
9. Precision and trueness of dental models manufactured with different 3-dimensional printing techniques10.1016/j.ajodo.2017.05.025 ↗
10. Effect of printing layer thickness on the trueness and fit of additively manufactured removable dies10.1016/j.prosdent.2022.10.011 ↗
11. Lim, Y. (2022). Influence of Different Postprocessing Rinsing Agents on the Manufacturing Accuracy of Dental Models Printed by LCD Resin 3D Printer. [Master’s Thesis, Texas A&M University]. Available online: https://hdl.handle.net/1969.1/197435.
12. Influence of post-polymerization processing on the mechanical characteristics of 3D-printed occlusal splints10.1088/1742-6596/1492/1/012018 ↗
13. Effects of postpolymerization conditions on the physical properties, cytotoxicity, and dimensional accuracy of a 3D printed dental restorative material10.1016/j.prosdent.2022.04.024 ↗
14. The anisotropicity of the flexural properties of an occlusal device material processed by stereolithography10.1016/j.prosdent.2016.03.018 ↗
15. Kang, B.-h., Son, K., and Lee, K.-b. (2020). Accuracy of Five Intraoral Scanners and Two Laboratory Scanners for a Complete Arch: A Comparative In Vitro Study. Appl. Sci., 10.10.3390/app10010074 ↗
16. In vitro comparison of five desktop scanners and an industrial scanner in the evaluation of an intraoral scanner accuracy10.1016/j.jdent.2022.104391 ↗
17. Nulty, A. (2021). A Comparison of Full Arch Trueness and Precision of Nine Intra-Oral Digital Scanners and Four Lab Digital Scanners. Dent. J., 9.10.20944/preprints202105.0165.v1 ↗
18. Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans10.4047/jap.2021.13.5.316 ↗
19. Accuracy and reproducibility of virtual edentulous casts created by laboratory impression scan protocols10.1016/j.prosdent.2017.11.024 ↗
20. Srivastava, G., Padhiary, S.K., Mohanty, N., Molinero-Mourelle, P., and Chebib, N. (2023). Accuracy of Intraoral Scanner for Recording Completely Edentulous Arches—A Systematic Review. Dent. J., 11.10.3390/dj11100241 ↗
21. Accuracy of a chairside intraoral scanner compared with a laboratory scanner for the completely edentulous maxilla: An in vitro 3-dimensional comparative analysis
22. The effects of additive manufacturing technologies and finish line designs on the trueness and dimensional stability of 3D-printed dies10.1111/jopr.13588 ↗
23. The epidemiology of edentulism and the associated factors: A literature Review10.4103/jfmpc.jfmpc_1181_19 ↗
24. Evaluation of the accuracy of the optical scanners used in the modern dental practice10.1088/1742-6596/1492/1/012017 ↗
25. Son, K., Lee, W.-S., and Lee, K.-B. (2021). Effect of Different Software Programs on the Accuracy of Dental Scanner Using Three-Dimensional Analysis. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18168449 ↗
26. Accuracy of five different 3D printing workflows for dental models comparing industrial and dental desktop printers
27. Accuracy of 3D Printed Models Created by Two Technologies of Printers with Different Designs of Model Base10.1111/jopr.13107 ↗
28. Evaluation of functional suitable digital complete denture system based on 3D printing technology10.4047/jap.2021.13.6.361 ↗
29. Trueness and precision of complete denture digital impression compared to conventional impression: An in vitro study10.7717/peerj.19075 ↗
30. Accuracy evaluation of complete-arch models manufactured by three different 3D printing technologies: A three-dimensional analysis10.2186/jpr.JPOR_2019_579 ↗
31. Tsolakis, I.A., Papaioannou, W., Papadopoulou, E., Dalampira, M., and Tsolakis, A.I. (2022). Comparison in Terms of Accuracy between DLP and LCD Printing Technology for Dental Model Printing. Dent. J., 10.10.3390/dj10100181 ↗
32. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research10.1016/j.jcm.2016.02.012 ↗
33. Mangano, F.G., Hauschild, U., Veronesi, G., Imburgia, M., Mangano, C., and Admakin, O. (2019). Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: A comparative in vitro study. BMC Oral Health, 19.10.1186/s12903-019-0792-7 ↗