Flow‐Through Microbial Capture by Antibody‐Coated Microsieves
Source abstract
Abstract
A new flow‐through method for rapid capture and detection of microorganisms is developed using optically‐flat microengineered membranes. Selective and efficient capture of Salmonella is demonstrated with antibodies coated on membranes (microsieves) having a pore size much larger than the microorganism itself. The silicon‐nitride membranes are first photochemically coated with 1,2‐epoxy‐9‐decene yielding stable Si–C and N–C linkages. The resultant epoxide‐terminated microsieves are subsequently biofunctionalized with anti‐Salmonella antibodies. The capture efficiency of antibody‐coated microsieves with different pore sizes (2.0–5.0 μm) is studied with Salmonella enterica enterica serotype Typhimurium suspensions (107 cfu mL–1). The antibody‐coated microsieves capture 52% (2 μm microsieves), 30% (3.5 μm microsieves), and 12% (5 μm microsieves) of Salmonella from the suspension. The influence of flow rate (0.8–16 μL min–1 mm–2) on the capture efficiency of antibody‐coated 3.5 μm microsieves is investigated. The capture efficiency increases from ≈30% to ≈70% when the flow‐rate decreases from 16 to 0.8 μL min–1 mm–2. Antibody‐coated 3.5 μm microsieves can capture Salmonella rapidly and directly from fresh milk suspension (capture 35% at concentration of 80 cfu mL–1). The use of antibody‐coated microsieves as microbial selective capture devices is thus shown to be highly promising for the direct capture of microorganisms.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Biosensors and Analytical Detection · Advanced biosensing and bioanalysis techniques · Microfluidic and Capillary Electrophoresis Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Laboratory of Organic Chemistry Wageningen University Dreijenplein 8 6703 HB Wageningen The Netherlands
Aquamarijn Micro Filtration Berkelkade 11 7201 JE Zutphen The Netherlands
Innosieve Diagnostics Nieuwe Kanaal 7A 6709 PA Wageningen The Netherlands
References (31)
Show source-provided references
1. 10.3390/s9060440710.3390/s90604407 ↗
2. 10.1016/j.fm.2010.04.00810.1016/j.fm.2010.04.008 ↗
3. 10.1016/S0167-7012(01)00304-910.1016/S0167-7012(01)00304-9 ↗
4. 10.1016/S0021-9673(03)00769-610.1016/S0021-9673(03)00769-6 ↗
5. 10.1039/c0lc00044b10.1039/c0lc00044b ↗
6. 10.1021/bm061197b10.1021/bm061197b ↗
7. 10.1016/j.bios.2008.06.04510.1016/j.bios.2008.06.045 ↗
8. 10.2174/138620704332881410.2174/1386207043328814 ↗
9. Opalka D. · Clin. Diagn. Lab. Immunol. · 2003 · 10 · 108
10. van Rijn C. J. M. · 2004
11. 10.1038/nmat88810.1038/nmat888 ↗
12. Hermanson G. T. · 2008
13. 10.1021/bm025766110.1021/bm0257661 ↗
14. 10.1021/la060331a10.1021/la060331a ↗
15. 10.1021/ac800809310.1021/ac8008093 ↗
16. 10.1016/j.ab.2007.07.01010.1016/j.ab.2007.07.010 ↗
17. 10.1016/0021-9797(84)90012-210.1016/0021-9797(84)90012-2 ↗
18. 10.1006/jcis.1993.117010.1006/jcis.1993.1170 ↗
19. 10.1021/la500533f10.1021/la500533f ↗
20. 10.1039/b923890p10.1039/b923890p ↗
21. 10.1021/la301056810.1021/la3010568 ↗
22. 10.1021/la203136310.1021/la2031363 ↗
23. 10.1021/am100985c10.1021/am100985c ↗
24. 10.1021/la104657c10.1021/la104657c ↗
25. 10.1021/la803094y10.1021/la803094y ↗
26. 10.1021/jp053816110.1021/jp0538161 ↗
27. 10.1016/0927-7765(95)98205-210.1016/0927-7765(95)98205-2 ↗
28. 10.1073/pnas.91.5.160410.1073/pnas.91.5.1604 ↗
29. 10.1016/0021-9797(88)90456-010.1016/0021-9797(88)90456-0 ↗
30. 10.1016/0009-2509(86)80016-110.1016/0009-2509(86)80016-1 ↗
31. 10.1063/1.316073210.1063/1.3160732 ↗