Effect of wire rupture on the mechanical behaviour of an external prestressing tendon
Source abstract
Abstract
External prestressing is a construction technique widely employed since the 1980s for large civil engineering structures to reduce the cross-sectional area of structures and thus their permanent load, and more recently to reinforce structures. External prestressing tendons are composed of strands, each comprising 7 wires with a very high elastic limit, laid in a HDPE sheath, anchored in reinforced concrete blocks and generally tensioned to 80% (excluding creep and shrinkage) of their ultimate tensile strength. To safeguard the cables, grout was injected into the sheaths. However, this protection system has not always prevented the corrosion of the strands. When wires and strands re-anchor through friction in the grout after fracturing due to corrosion, the stress on the remaining tendon increases until the breaking load of the entire tendon is reached. The sudden release of energy from such a break can jeopardize the structure and endanger any personnel present on-site. Therefore, understanding the state of the cable at a given level of degradation and the permissible degradation before failure is crucial for structure managers. Several 46 m long cables between supports were tested and brought to failure by the progressive cutting of the wires composing the strands. Initially, three tendons, each comprising a single strand of seven wires, were tested. Subsequently, three tendons, each comprising five strands, were examined. The experiments conducted and the analysis of the results have enhanced the understanding of the evolution of tension in the tendon as it becomes damaged. To this end, a model was developed to estimate the length affected by wire ruptures. This work also presents findings regarding the transfer of stresses within the tendon and strands resulting from these ruptures. Finally, a model that estimates tension loss due to the sliding of wires after they break is presented. • Damage has been reproduced wire-wise for external prestressing tendon. • Breaking occur after around a third wires break. • Tension loss is minimal. • Re-anchoring length and tension loss can be estimated using damage level.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Properties and Behavior · Structural Engineering and Vibration Analysis · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Godart · 2014
2. Bond and re-anchoring tests of post-tensioned steel tendon in case of strand failure inside cement grouting with voids10.1002/suco.202000351 ↗
3. Modeling and parametric study of the reanchorage of ruptured tendons in bonded posttensioned concrete10.1061/(ASCE)ST.1943-541X.0001898 ↗
4. Experimental and numerical evaluation of unbonded posttensioning tendons subjected to wire breaks10.1061/(ASCE)BE.1943-5592.0000940 ↗
5. Evaluation for flexural-load capacity of prestressed concrete girders with broken tendons10.2219/rtriqr.52.224 ↗
6. Mechanical model for unbonded seven-wire tendon with symmetric wire breaks
7. Neutron diffraction measurement of stress redistribution in parallel seven-wire strands after local fracture10.1007/s11340-012-9621-5 ↗
8. Martin · 2012
9. Dilation behavior of seven-wire prestressing strand – the hoyer effect10.1016/j.conbuildmat.2012.11.064 ↗
10. Theoretical analysis of transfer lengths in pretensioned prestressed concrete members
11. A higher-order equation for modeling strand bond in pretensioned concrete beams
12. Response of a strand to axial and torsional displacements10.1243/JMES_JOUR_1973_015_045_02 ↗
13. Response of a wire rope strand to axial and torsional loads: asymptotic modeling of the effect of interwire contact deformations10.1016/j.ijsolstr.2011.01.021 ↗
14. Tests of unbonded seven-wire tendon with broken outer wires
15. Mechanical model for unbonded seven-wire tendon with single broken wire
16. Static response of asymmetrically damaged metallic strands: experimental and numerical approach10.1016/j.conbuildmat.2018.10.092 ↗
17. Evaluation of the coupled effect of strain localization and asymmetric damage distribution on rope response: numerical approach based on a nonlinear cable-beam element10.1016/j.engstruct.2020.110258 ↗
18. An investigation on stressing and breakage response of a prestressing strand using an efficient finite element model10.1016/j.engstruct.2016.05.030 ↗
19. Experimental evaluation of vibration response of external post-tensioned tendons with corrosion10.1007/s12205-019-0735-5 ↗
20. Evaluer l’état de la précontrainte : avancées récentes dans le développement de méthodes non destructives d’auscultation.
21. Mechanical impact of wires break in grouted external prestressing tendon
22. The effect of rock mass confinement on the bond strength of fully grouted cable bolts10.1016/0148-9062(92)92634-O ↗
23. Effect of stress corrosion cracking on stress–strain response of steel wires used in prestressed concrete beams10.1016/j.corsci.2009.03.033 ↗
24. Long-term experimental study and prediction of the mechanical performance on corroded prestressing steel strands subjected to marine salt spray environment10.1016/j.conbuildmat.2024.136069 ↗
25. Comprehensive assessment of prestress loss in post-tensioned prestressed concrete structures exposed to wet-dry cycles in chloride environments10.1016/j.engstruct.2025.119691 ↗
26. Modeling the axial-torsional response of metallic strands accounting for the deformability of the internal contact surfaces: derivation of the symmetric stiffness matrix10.1016/j.ijsolstr.2019.05.008 ↗
27. Validity and limitations of linear analytical models for steel wire strands under axial loading, using a 3D FE model10.1016/j.ijmecsci.2007.03.014 ↗
28. A model to predict the coupled axial torsion properties of ACSR electrical conductors10.1007/BF02326388 ↗