journal article·2025-12Open access

Influence of elevated temperature on the performance of pre-damaged grouted sleeve connections under tension and compression

Jinyi Zhang, Xianzhong Xie, Jialu Wang, Yibo Zhou, Ao Wang, Weijian Yi

Abstract

This study investigates the performance of grouted sleeve connections (GSCs) under post-earthquake fire conditions. A total of 62 specimens were fabricated with variations in anchorage length (6 d , 7 d , 8 d ), pre-damage protocol (unidirectional and cyclic loading), and exposure temperature (20°C to 800°C). The response was evaluated based on residual deformation, hysteretic behavior, failure mode, strength, deformation capacity, and bond stress. Results indicate that GSCs become increasingly susceptible to rebar pull-out failure when subjected to shorter anchorage lengths, more severe pre-damage, and higher temperatures. Both yield strength and ultimate displacement decrease with increasing temperature. The ultimate strength of connections failing in pull-out is significantly lower than those failing by rebar fracture. Furthermore, while GSCs exhibiting rebar fracture satisfy standard performance evaluation criteria, those failing by pull-out do not. A bond stress coefficient k is proposed; for GSCs with an 8 d anchorage length, a value of k > 1.80 is recommended to prevent premature pull-out and ensure a ductile fracture failure mode.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Building energy efficiency and green building development plan[J]. Installation, 2022(5):1-6.(In Chinese).
2. Experimental research on dynamic mechanical properties of fully-grouted sleeve connections10.1016/j.conbuildmat.2021.123125 ↗
3. Review of post-earthquake fire hazard to building structures10.1139/L08-029 ↗
4. Vulnerability evaluation of post-earthquake fire ignition of building structures
5. A procedure to simulate spread of post-earthquake fire in urban area considering seismic damage to buildings10.1007/s11069-024-06778-9 ↗
6. Experimental Study and Bond Slip Analysis on Mechanical Properties of Half Grout Sleeve Splicing of Rebars after High Temperature
7. WEN DY · 2020
8. Zhu J.N., Guo D.D., Ma J.F. Experimental study on tensile properties of semi-grouting sleeve after high temperature engineering mechanics, 2020, 37(5): 104-111 (In Chinese).
9. Deng X. Study on Mechanical Properties of the Reinforced Half Grouting Sleeve Connection under and after High Temperature. Hunan University, 2018(In Chinese).
10. Experimental study on post fire tensile properties of reinforcing rebars connected by grout-filled splice sleeves10.4028/www.scientific.net/KEM.773.305 ↗
11. Postfire mechanical behaviors of grouted sleeve connections under strong earthquakes10.1007/s10694-023-01455-y ↗
12. Comparison of tensile mechanical properties of half grouted sleeve connection at elevated and post-elevated temperature: An experimental study10.1016/j.conbuildmat.2024.136723 ↗
13. Bond performance prediction model of defective grout in post-fire sleeve connections under cyclic loading10.1016/j.conbuildmat.2023.132442 ↗
14. Experimental study on effect of loading mode and anchorage length on connection behaving of grouting sleeve for rebars splicing [J]
15. Bond performance prediction model of defective grout in post-fire sleeve connections under cyclic loading10.1016/j.conbuildmat.2023.132442 ↗
16. Study on uniaxial tensile test of half grouted sleeve connection with axial eccentric rebar after high temperature
17. Experimental Research on Mechanical Properties of Semi-Grouting Sleeve Connection After Being Subjected to High Temperature
18. Study on uniaxial tensile test of grouting sleeve of seamless steel pipe after high temperature
19. Uniaxial tensile behavior of half-grouted sleeve connections with concrete cover after exposure to elevated temperatures
20. Post-fire mechanical properties of half-grouted sleeve connectors with grouting defects10.3390/buildings14051434 ↗
21. Post-fire mechanical properties of full-grouted sleeve connection with different grouting defects
22. Post-fire mechanical behavior and simplified stress-strain model of grouted sleeve connections
23. Experimental study on seismic performance of large-diameter grouted sleeve connections and precast bridge piers10.1016/j.istruc.2025.108791 ↗
24. Experimental and numerical investigation of the seismic behaviour of corroded precast concrete piers with grouting sleeve connections10.1080/15732479.2023.2209070 ↗
25. Seismic behaviour of prefabricated square reinforced concrete-filled steel tubular pier with a grouting sleeve connection10.1016/j.engstruct.2025.120414 ↗
26. JGJ 355-2015. Technical specification for grout sleeve splicing of rebars [S].2015. (In Chinese).
27. GB/T 228.1-2021. Metallic materials-Tensile testing Part 1: Method of test at room temperature [S].2021. (In Chinese).
28. JGJ107-2016. Technical specification for mechanical splicing of steel reinforcing bars. [S].2016. (In Chinese).
29. Numerical simulation method for quantitative assessment of fully-grouted sleeve connection damage state and performance under thermal coupling10.1016/j.ijthermalsci.2023.108789 ↗
30. The relationship between interlocking mechanism and bond strength in elastic and inelastic segment of splice sleeve10.1016/j.conbuildmat.2014.01.020 ↗
31. Effect of sleeve inner cavity structure on bond performance of grouted pipe splice