A UHP-ECC surface layer combined with a wire mesh strengthening method for brick masonry walls: Experimental investigation on seismic behavior
Source abstract
Abstract
Many existing brick masonry structures require strengthening due to low mortar strength and inadequate seismic detailing. Considering their cost-effectiveness and ease of construction, a UHP-ECC surface layer combined with a wire mesh is proposed for strengthening brick masonry walls. The tests employed wall thicknesses of 180 mm and 240 mm and strengthening forms of single- and double-sided as parameters. Six specimens, including four strengthened walls and two unstrengthened walls, were tested under low-cycle reversed loading. A validated finite element model was further employed to analyze the effects of vertical compressive stress, aspect ratio, and mortar strength. The strengthened walls exhibited significant increases in peak and ultimate loads, stiffness, ductility, and energy dissipation, with double-sided strengthening performing the best. Thicker walls showed greater cumulative energy dissipation, whereas unstrengthened walls experienced early cracking and rapid damage progression. Parameter analysis showed that higher vertical compressive stress and mortar strength, as well as a lower aspect ratio, significantly increased load-bearing capacity. A shear capacity formula for UHP-ECC strengthened brick masonry walls is proposed, providing an experimental and theoretical basis for seismic strengthening design. • The UHP-ECC surface layer strengthening method is proposed for brick masonry walls. • The UHP-ECC surface layer effectively restrains wall deformation and enhances shear capacity. • Double-sided strengthening significantly improves ductility and energy dissipation capacity. • The effects of vertical compressive stress, aspect ratio, and mortar strength on seismic behavior are investigated. • A shear capacity calculation formula is proposed and validated against experimental results.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Seismic Performance and Analysis · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (44)
Show source-provided references
1. In-plane seismic response of brick masonry walls10.1002/(SICI)1096-9845(199711)26:11<1091::AID-EQE693>3.0.CO;2-6 ↗
2. Evaluation of the seismic performance of brick masonry walls10.1002/stc.299 ↗
3. Seismic rehabilitation of brick masonry walls with central openings using hybrid GFRP configurations10.1016/j.jobe.2025.113464 ↗
4. Seismic behavior of semi-confined vs. confined brick masonry structures: An experimental analysis10.1016/j.istruc.2025.108339 ↗
5. Brick masonry panels strengthened with textile reinforced mortar: experimentation and numerical analysis10.1016/j.conbuildmat.2019.117061 ↗
6. The behavior of masonry walls with reinforced plaster mortar10.1155/2013/436946 ↗
7. Numerical analysis of the load-bearing capacity of brick masonry walls strengthened with textile reinforced mortar and subjected to eccentric compressive loading10.1016/j.engstruct.2015.02.032 ↗
8. Comparative experimental analysis on the in-plane shear performance of brick masonry walls strengthened with different fiber reinforced materials10.1016/j.conbuildmat.2020.120387 ↗
9. Shear strengthening of unreinforced masonry wall with different fiber reinforced mortar jacketing10.1016/j.conbuildmat.2015.10.095 ↗
10. Review of strengthening techniques for masonry using fiber reinforced polymers10.1016/j.compstruct.2016.10.132 ↗
11. Out-of-plane response of ECC-strengthened masonry walls
12. Diagonal shear performance of unreinforced masonry wall strengthened with hybrid basalt-PE fibers engineered cementitious composites (HF-ECC)
13. Out-of-plane testing of unreinforced masonry walls strengthened using ECC shotcrete10.1016/j.istruc.2016.04.005 ↗
14. Experimental investigation on seismic behavior of brick masonry wall strengthened with ECC splint10.1016/j.conbuildmat.2023.131627 ↗
15. In-plane strengthening of clay brick unreinforced masonry wallettes using ECC shotcrete10.1016/j.engstruct.2014.01.043 ↗
16. Seismic shear behavior of masonry walls strengthened with engineered cementitious composites (ECC)
17. Direct tensile properties and stress–strain model of UHP-ECC10.1061/(ASCE)MT.1943-5533.0002975 ↗
18. Rate-dependent tensile properties of ultra-high performance engineered cementitious composites (UHP-ECC)10.1016/j.cemconcomp.2018.07.016 ↗
19. Experimental investigations on tensile and shear behavior of the interface between UHP-ECC and concrete10.1186/s40069-024-00679-8 ↗
20. Structural behaviors of ultra-high performance engineered cementitious composites (UHP-ECC) beams subjected to bending—experimental study10.1016/j.conbuildmat.2018.05.122 ↗
21. Experimental case study for practical implementation of real pre-stressed two-layer reinforced concrete beams10.1016/j.istruc.2022.11.084 ↗
22. Recent trends in steel-fibered high-strength concrete10.1016/j.matdes.2011.03.030 ↗
23. Two-layer pre-stressed beams consisting of normal and steel-fibered high-strength concrete10.1016/j.matdes.2007.04.013 ↗
24. Experimental and numerical simulation study on the interfacial shear performance of UHPECC-reinforced existing brick wall
25. Experimental study and application of seismic performance of 180-mm-thick brick masonry walls strengthened with UHP-ECC
26. Effect of cement substitution by limestone on the hydration and microstructural development of ultra-high performance concrete (UHPC)10.1016/j.cemconcomp.2016.12.009 ↗
27. Chloride-induced corrosion of steel fiber near the surface of ultra-high performance concrete and its effect on flexural behavior with various thickness10.1016/j.conbuildmat.2019.07.063 ↗
28. Ministry of Industry and Information Technology of the People’s Republic of China. Standard test method for the mechanical properties of ductile fiber reinforced cementitious composites: JC/T 2461—2018. Beijing: China Building Materials Industry Press; 2018. (In Chinese).
29. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China. Test methods for wall bricks: GB/T 2542—2012. Beijing: Standards Press of China; 2012. (In Chinese).
30. Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Standard for test method of basic properties of construction mortar: JGJ/T 70—2009. Beijing: China Architecture & Building Press; 2009. (In Chinese).
31. A review of analytical methods in the current design processes and assessment of performance of masonry structures10.1016/j.conbuildmat.2012.07.095 ↗
32. Building response to excavation induced settlement10.1061/(ASCE)0733-9410(1989)115:1(1) ↗
33. Zeolite to improve strength-shrinkage performance of high-strength engineered cementitious composite10.1016/j.conbuildmat.2019.117335 ↗
34. Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Specification for seismic test of buildings: JGJ/T 101—2015. Beijing: China Architecture & Building Press; 2015. (In Chinese).
35. Park R. State of the art report: ductility evaluation from laboratory and analytical testing. In: Proceedings of the Ninth World Conference on Earthquake Engineering. 1988; Tokyo/Kyoto, Japan. p. 605–616.
36. Simulating masonry wall behaviour using a simplified micro-model approach10.1016/j.engstruct.2017.08.021 ↗
37. Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Ultra high performance concrete: GB/T 31387—2025. Beijing: China Architecture & Building Press; 2025. (In Chinese).
38. Seismic performance of confined brick masonry structure for multistory buildings: a comparative study10.1617/s11527-025-02665-2 ↗
39. Bond strength and compressive stress-strain characteristics of brick masonry10.1016/j.jobe.2016.11.006 ↗
40. Analysis on seismic shear strength of masonry structures
41. The heuristic vulnerability model: fragility curves for masonry buildings10.1007/s10518-021-01063-7 ↗
42. Seismic strength of masonry houses
43. Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Code for design of strengthening masonry structures: GB 50702—2011. Beijing: China Architecture & Building Press; 2011. (In Chinese).
44. Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Technical specification for seismic strengthening of buildings: JGJ 116—2009. Beijing: China Architecture & Building Press; 2009. (In Chinese).