journal article·2026-03Open access

Mechanical properties of vertically and horizontally cored clay bricks and masonry ties used in double brick walls

Sarkar Noor-E-Khuda, Stefan Brestovac

Abstract

Post-COVID-19, Western Australia (WA) has recorded an increased demand for single and double-story residential homes due to record-high migration and mining activities in the state. The majority of these homes are constructed using the double brick (DB) construction technique, where a combination of vertically cored (VCore) and horizontally cored (HCore) clay bricks is used. A review of the literature reveals that no research data is available on the material properties of the VCore and HCore bricks, mortar, masonry and masonry wall ties, which are extensively used in WA. A systematic material-level experimental investigation is thus carried out to determine their material properties. A total of ten different material properties tests were conducted, including mortar compressive and flexural strength, dimensional tolerance, compressive strength and modulus of rupture of masonry unit, compressive and flexural tensile strength of masonry piers, tensile and compressive strength of wire ties, and masonry tie pull-out bond strength using two test methods. All tests were performed according to relevant Australian and international standards. It is found that the performance of the bricks and masonry varied with changes in the arrangement of cores.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Hygrothermal properties of building materials · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Housing Industry Association · 2025
2. Mining Magazine · 2025
3. Urban Development Institute of Australia: Western Australia. (2020). Modern Methods of Housing Construction. Retrieved from 〈https://www.udiawa.com.au/wp-content/uploads/2021/01/FINAL-UDIA-Report-Modern-Methods-of-Construction.pdf〉.
4. Reinforcement of brick walls spanning vertically10.1061/(ASCE)0733-9445(1987)113:2(334) ↗
5. Laboratory testing of strengthened cavity unreinforced masonry walls10.1061/(ASCE)ST.1943-541X.0001987 ↗
6. Shaking table test on a full scale URM cavity wall building10.1007/s10518-017-0185-8 ↗
7. Out-of-plane shaking table tests on URM single leaf and cavity walls10.1016/j.engstruct.2016.07.011 ↗
8. Standards Australia · 2015
9. Strengthening of unreinforced masonry walls using FRPs10.1061/(ASCE)1090-0268(2001)5:2(76) ↗
10. In-situ out-of-plane testing of unreinforced masonry wall segment in Wintec Block F Building
11. Flexural displacement response of NSM FRP retrofitted masonry walls10.1016/j.conbuildmat.2012.06.065 ↗
12. Rehabilitation of masonry walls using unobtrusive FRP techniques for enhanced out-of-plane seismic resistance10.1061/(ASCE)1090-0268(2006)10:3(213) ↗
13. Lunn · 2013
14. Out-of-plane flexural behavior of unreinforced red brick walls strengthened with FRP composites10.1016/j.compositesb.2006.07.019 ↗
15. In situ out-of-plane testing of unreinforced masonry cavity walls in as-built and improved conditions10.1016/j.istruc.2015.04.005 ↗
16. Damaged masonry walls in two-way bending retrofitted with vertical FRP strips10.1016/j.conbuildmat.2007.09.007 ↗
17. Mechanical properties of clay masonry units: Destructive and ultrasonic testing10.1016/j.conbuildmat.2019.05.166 ↗
18. Determination of Mohr–Coulomb failure envelope, mechanical properties and UPV of commercial cement-lime mortar10.1617/s11527-022-01959-z ↗
19. Influence of aggregates grading and water/cement ratio in workability and hardened properties of mortars10.1016/j.conbuildmat.2010.11.011 ↗
20. Influence of wetting–drying cycles on compressive and flexural strength of cement mortar and CFRP-mortar bond strength10.1016/j.conbuildmat.2020.121513 ↗
21. Standards Australia · 2018
22. Standards Australia. (2014). AS/NZS 1012.9-2014: Method of testing concrete compressive strength tests - concrete, mortar and grout specimens. In. Sydney: Standards Australia.
23. Standards Australia. (2003a). AS 4456.3 - 2003: determining dimensions. In. Sydney: Standards Australia.
24. Standards Australia. (2003b). AS 4456.4 - 2003: Masonry units, segmental pavers and flags: Methods of test Determining compressive strength of masonry units. In. Sydney: Standards Australia.
25. Standards Australia. (2003d). AS/NZS 4456.5 - 2003: Masonry units, segmental pavers and flags: Methods of test Determining the breaking load of segmental pavers and flags In. Sydney: Standards Australia.
26. Standards Australia. (2003c). AS 4456.15 - 2003: determining lateral modulus of rupture. In. Sydney: Standards Australia.
27. Standards Australia. (2020a). AS 2699.1 - 2020: built-in components for masonry construction Part1: Wall ties. In. Sydney: Standards Australia.
28. Seismic assessment of out-of-plane loaded unreinforced masonry walls. Doctoral dissertation
29. Out-of-plane flexural strength of unreinforced clay brick masonry walls
30. Development of thin layer mortared concrete masonry, Doctoral dissertation
31. Unreinforced masonry walls subjected to out-of-plane seismic actions Doctoral dissertation
32. Experimental characterization of the axial behavior of traditional masonry wall metal tie connections in cavity walls10.1016/j.conbuildmat.2020.121141 ↗
33. Mechanical modelling of the axial behaviour of traditional masonry wall metal tie connections in cavity walls10.1016/j.conbuildmat.2021.125205 ↗
34. Historical development and observed earthquake performance of unreinforced clay brick masonry cavity walls
35. Experimental assessment of the mechanical behaviour of ties on brick veneers anchored to brick masonry infills10.1016/j.conbuildmat.2017.09.013 ↗
36. Shear behavior of corrugated tie connections in anchored brick veneer–wood frame wall systems10.1061/(ASCE)MT.1943-5533.0000143 ↗
37. European Standard · 2016
38. ASTM C348 · 2021
39. Think Brick Australia, The Properties of Clay Masonry Units, Retrieved from, 2013. 〈www.littlehamptonbrick.com.au/wp-content/uploads/2018/09/manual-2-the-properties-of-clay-masonry-units.pdf〉.
40. Double brick walls with partial-height steel mullions under one-way vertical bending
41. Experimental investigation on out-of-plane bending of double brick walls
42. The use of characteristic strengths in masonry design10.1080/13287982.2007.11464978 ↗
43. Unreinforced masonry walls under two-way out-of-plane bending: Comparison of FE model predictions with analytical models