journal article·2026-04Open access

Early-age thermo-mechanical behaviour of a laboratory-scale thermo-active wall: Experimental measurements and numerical modelling

Habib Abdelhak Mesbah, Paul Byrne, Abdelouhab Labihi, Amina Meslem

Abstract

As in tunnels or underground infrastructures, walls and inverts of metro stations can be used as geothermal collectors. The thermo-mechanical behaviour of concrete used in such walls was studied at early age using experimental and numerical approaches. A laboratory-scale reinforced thermo-active concrete block, designed to reproduce diaphragm-wall-type restraint and realistic thermal boundary conditions, was instrumented with embedded vibrating-string extensometers to monitor internal temperatures and strains from casting prior to any operational thermal activation. Semi-adiabatic calorimetry was used to derive the adiabatic temperature-rise curve for calibrating the thermal–hydration model. Simulations performed with CESAR-LCPC using the coupled TEXO–MEXO framework reproduced the measured temperature and strain evolutions at several locations, demonstrating the robustness of the proposed workflow when combined with an effective-modulus approach based on fib Model Code 2010 for early-age stress relaxation. The validated model was then used to investigate scale effects and boundary heat exchange, and to compare CEM III/B and CEM I concretes. Cracking risk was screened using a stress-to-strength indicator and quantified by a volumetric cracking index. A complementary spatial analysis was introduced to characterise the location of tensile overstress zones and the influence of reinforcement. Peak CI values at 24 h under laboratory boundary conditions were about 2.20% for CEM III/B and 2.12% for CEM I, while in-situ boundary conditions reduced CI to about 1.78% and 0.77%, respectively; at later ages, CI remained limited, typically below 1% for the investigated configurations. The results highlight the role of base restraint in controlling the position of critical zones and the influence of reinforcement, including bar diameter, on the intensity of local stress concentrations. Finally, operational thermal cycling representative of geothermal activation produced very small measured deformations, confirming that the structural integrity of the block was maintained at early age and after activation. • Thermo-mechanical behaviour of concrete block was modelled with CESAR-LCPC. • The concrete block is representative of walls and inverts of metro stations. • The model is consistent with strains vibrating-string extensometers data. • Strains depend on elastic, thermal, autogenous shrinkage and creep effects. • The risk of cracking at early age remains low and localised in the block.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Seismic and Structural Analysis of Tall Buildings · Structural Analysis and Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Energy geostructures: a review of analysis approaches, in situ testing and model scale experiments
2. Assessment of cracking risk of concrete due to restrained strain based on zero-stress temperature and cracking temperature10.1016/j.conbuildmat.2023.131381 ↗
3. Granger · 1995
4. Swelling, shrinkage and creep: a mechanical approach to cement hydration10.1007/BF02480632 ↗
5. Numerical analysis of the early age behavior of concrete structures with a hydration based microplane model10.1016/j.compstruc.2009.05.008 ↗
6. Degree of restraint concept in analysis of early-age stresses in concrete walls10.1016/j.engstruct.2015.08.025 ↗
7. Geometry of crack network and its impact on transport properties of concrete10.1016/j.cemconres.2012.05.017 ↗
8. Thermal behaviour of geothermal diaphragm walls: evaluation of exchanged thermal power10.1016/j.renene.2018.11.068 ↗
9. Early-age behaviour of concrete nuclear containments10.1016/j.nucengdes.2008.04.009 ↗
10. CESAR-LCPC Software, CESAR Material models, Edited by IFFSTAR, France. Accessed online on 18 June 2025 at 〈https://www.cesar-lcpc.com/documents/Manuals/EN/CESAR-MU-MM-v31-EN.pdf〉.
11. CESAR-LCPC Software, Concrete at early ages analysis, Theory and application. Edited by ITECH, France. Accessed online on 18 June 2025 at 〈https://www.cesar-lcpc.com/documents/2015-10-FICHES-CESAR-TM-EN.pdf〉.
12. NF EN 1992-1-1, Eurocode 2 - Calcul des structures en béton - Partie 1-1: règles générales et règles pour les bâtiments (P18-711-1:2005-10, NA:2016-03, A1:2015-02).
13. Model Code 2010 - First complete draft, Volume 1, fib Bulletin No. 55, 2010, 318 pages, ISBN: 978-2-88394-095-6, doi.org/10.35789/fib.BULL.0055.
14. M. Chen Austin, T. Vogt Wu, A. Sempey, D. Bruneau, A. Sommier, Experimental assessment of Peltier modules as an alternative to conventional heat flux meters, Congrès Français de Thermique SFT 2019, Nantes, 2019.
15. AASHTO T 336-22 · 2022
16. Separation of thermal and autogenous shrinkage at varying temperatures using optical fiber sensors10.1016/j.cemconcomp.2007.01.005 ↗
17. A finite element-based methodology for the thermo-mechanical analysis of early-age behavior in concrete structures10.1186/s40069-019-0353-0 ↗
18. Influence of constituents and composition on autogenous shrinkage of cementitious materials10.1680/macr.1997.49.178.15 ↗
19. Numerical simulations of the early-age behavior of concrete structures: modeling and feedback
20. Numerical study on the thermal-induced mechanical behavior in deep energy diaphragm wall (EDW): the long-term soil elastoplastic effects10.1016/j.tust.2022.104860 ↗