journal article·2026-05Open access

Structural performance of timber-framed shear walls of various configurations

Tom P. Slattery, Craig J.L. Cowled, Nor Hafizah Ramli Sulong, Keith Crews, Harrison Brooke

Abstract

Timber-framed shear walls are commonly used in residential construction to resist the lateral forces from wind and earthquakes. In Australia, the residential construction standard AS1684 provides construction details and ultimate racking capacities for several commonly used bracing walls. However, these construction details rely on limited and, in some cases, outdated experimental data. This paper investigates some of these construction details to validate the design capacities in AS1684, namely a comparison of plywood thickness and stress grade, the effect of nailing pattern and tiedown, joint strength group of the timber framing, double-sided bracing walls and pretensioned steel strap bracing. Test panels of 2700 mm (H) × 2400 mm (L) or 2700 mm (H) × 2700 mm (L) were constructed using various construction details, as well as being clad in 10 mm plasterboard, and were tested using a monotonic loading protocol to failure. No statistically significant difference was observed for shear walls clad with different plywood thicknesses and stress grades. Panels constructed using the nailing pattern and tiedown from Method A, Detail (h), Table 8.18, AS1684.2, achieved a 24 % increase in ultimate capacity compared to panels constructed using Method B of the same detail in AS1684.2, which has a tighter nailing pattern and no tiedown. The joint strength group of the timber framing was found to have limited effect on the performance of timber-framed shear walls. Double-sided bracing walls did not achieve the expected double the capacity of a single-sided bracing wall. A comparison of two different pretensioned steel strap construction details showed no statistically significant difference between the two details.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Wood Treatment and Properties · Masonry and Concrete Structural Analysis · Seismic Performance and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Standards Australia · 2021
2. Influence of loading protocol on the structural performance of timber-framed shear walls10.1016/j.conbuildmat.2021.123103 ↗
3. Results of Timber-Framed Shear Wall Tests
4. The effect of sheathing material on racking performance of plywood shear wall10.5552/drvind.2022.2039 ↗
5. The Dynamic Response of Timber Shear Walls
6. Standards Australia · 2012
7. Influence of weathering on the structural performance of sheathing-to-timber connections10.3390/f14040734 ↗
8. Parametric evaluation of racking performance of platform timber framed walls10.1016/j.istruc.2017.08.003 ↗
9. Structural characteristics of light-frame wood shear walls with various construction detailing10.1016/j.engstruct.2019.110093 ↗
10. Strength and Stiffness of Strong Double-Sided Wood-Frame Shear Walls with Continuous Steel Rod Hold-Downs in Mid-rise Timber Structures
11. Efficient nonlinear modeling of strong wood frame shear walls for mid-rise buildings10.1016/j.engstruct.2020.110670 ↗
12. Study of Deflection of Single and Multi-Storey Light Frame Wood Shear Walls
13. Monotonic and cyclic behaviour of wood frame shear walls for mid-height timber buildings10.1016/j.engstruct.2019.03.043 ↗
14. Standards Association of Australia, CA65-1972 SAA Timber Engineering Code, 1972.
15. Standards Australia · 2010
16. European Committee for Standardization · EN 1995-1-12004 + A12008 Eur. 5 Des. Timber Struct. Part 1-1 Gen. Common rules rules Build. · 2004
17. M. Patton-Mallory, R.M. Gutkowski, L.A. Soltis, Racking performance of light-frame walls sheathed on two sides, US Department of Agriculture, Forest Service, Forest Products Laboratory, 1984.
18. Experimental and analytical assessment of the combined in-plane bending-shear behavior of timber frame walls10.1016/j.engstruct.2025.121068 ↗
19. Gattesco · 2012
20. R. Wolfe, Contribution of Gypsum Wallboard to Racking Resistance of Light-Frame Walls, USDA Forest Service Research Paper FPL (Forest Products Laboratory) (1983).
21. Lateral resistance of strapped wood shear walls
22. Experimental Study of The Structural Behaviour of Residential Timber-Framed Shear Walls
23. Influence of Plasterboard on the Structural Performance of Timber-Framed Shear Walls
24. The Length of Plywood Shear Walls Matters
25. European Committee for Standardization, EN 594:2011. Timber structures – Test methods – Racking strength and stiffness of timber frame wall panels., Brussels, Belgium, 2011.
26. Splitting capacity of bottom rail in partially anchored timber frame shear walls with single-sided sheathing10.1080/19373260.2014.898558 ↗
27. Effects of finish materials and dynamic loading on the cyclic response of woodframe shearwalls10.1061/(ASCE)0733-9445(2003)129:10(1394) ↗
28. Light-frame shear wall length and opening effects10.1061/(ASCE)0733-9445(1985)111:10(2227) ↗
29. Standards Australia · 1997
30. Preliminary experimental study of midply trussed shear walls
31. ASTM International, E564 − 06: Standard Practice for Static Load Test for Shear Resistance of Framed Walls for Buildings, West Conshohocken, PA, 2018.
32. ASTM International, E2126 − 11: Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Vertical Elements of the Lateral Force Resisting Systems for Buildings, West Conshohocken, PA, 2018.
33. Experimental investigation on sheathing-to-framing connections in wood shear walls10.1016/j.engstruct.2013.08.039 ↗
34. Analysis of fully anchored light-frame timber shear walls—elastic model10.1617/s11527-008-9463-x ↗
35. Racking deformations in wood shear walls10.1061/(ASCE)0733-9445(1985)111:2(257) ↗
36. Static and dynamic analysis of timber shear walls10.1139/l90-073 ↗
37. Coupled and uncoupled nonlinear elastic finite element models for monotonically loaded sheathing-to-framing joints in timber based shear walls10.1016/j.engstruct.2010.05.018 ↗
38. Lateral resistance of sheathing-to-framing nailed joints with an intermediate insulation layer10.1061/(ASCE)ST.1943-541X.0003026 ↗
39. Behaviour of nailed timber-plywood connections under monotonic and cyclic loading
40. Investigation of wood shear walls subjected to lateral load10.1016/j.istruc.2018.08.007 ↗
41. Small-scale rack testing of wood-frame shear walls
42. Effect of overturning restraint on performance of shear walls
43. Stress distribution among sheathing-to-frame nails of timber shear walls related to different base connections: experimental tests and numerical modelling10.1016/j.conbuildmat.2016.06.079 ↗
44. Experimental study of the effects of continuous rod hold-down anchorages on the cyclic response of wood frame shear walls10.1016/j.engstruct.2020.111641 ↗