Experimental investigation on flexural response of post-tensioned concrete girders strengthened with near-surface mounted carbon fiber reinforced polymers
Source abstract
Abstract
High-strength steel used in post-tensioned (PT) concrete structures significantly enhances serviceability and load-carrying capacity. However, without adequate protective measures, it is prone to corrosion, posing a critical risk to aging infrastructures. Combined with low residual prestress and heavy loading, this can precipitate premature failure. This study explores the effectiveness of Near Surface Mounted (NSM) Carbon Fiber-Reinforced Polymer (CFRP) systems for strengthening PT girders, leveraging their high strength-to-weight ratio and corrosion resistance. Experimental tests were conducted on four reduced-scale PT girders: two as-built (unstrengthened) specimens with different initial prestress levels and the others with equivalent prestress levels strengthened with NSM CFRP strips. Flexural behavior was evaluated at both global and local scales, analyzing force–displacement responses and load-induced strains in the CFRP strips under both monotonic and cyclic loading. Results reveal that NSM CFRP strips increased the load-carrying capacity by up to 44% compared to the as-built configuration. Analytical parametric analysis was conducted by varying the main mechanical properties of the strengthened girders. This research provides a robust framework for assessing and maintaining aging PT structures, highlighting the superior enhancement of flexural strength over ductility offered by NSM CFRP systems. • NSM CFRP system is investigated for strengthening PT concrete bridge girders. • The system increases flexural capacity by up to 44% with reduced ductility. • CFRP strips reached 57%–63% of their ultimate tensile strain with no debonding. • Analytical moment–curvature study supports experimental results (small model error). • Higher concrete strength increases ultimate bending moment while reducing ductility.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Masonry and Concrete Structural Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (51)
Show source-provided references
1. Efficiency of shear strengthening of RC beams with externally bonded FRP materials – state-of-the-art in the experimental tests10.1016/j.compstruct.2021.113891 ↗
2. Shear strengthening of reinforced concrete deep beams using near-surface mounted hybrid carbon/glass fibre reinforced polymer strips10.1016/j.engstruct.2020.110412 ↗
3. Strengthening of reinforced concrete beams by using fiber-reinforced polymer composites: a review
4. Flexural performance of RC beams strengthened with HB CFRP plates: experimental study and theoretical model based on the intermediate crack debonding10.1016/j.conbuildmat.2024.139444 ↗
5. TG 9.3. fib Bulletin No. 14: Externally Bonded FRP Reinforcement for RC Structures. 2001.
6. European Committee for Standardization. FprEN 1998-1-2:2025. Eurocode 8 — Design of Structures for Earthquake Resistance — Part 1-2: Buildings. Bruxelles: 2022.
7. Bond efficiency of EBR and NSM FRP systems for strengthening concrete members10.1061/(ASCE)CC.1943-5614.0000204 ↗
8. Experimental study of the influence of adhesive properties and bond length on the bond behaviour OF NSM FRP bars in concrete10.3846/13923730.2014.914097 ↗
9. Short- and long-term deflections of RC slabs strengthened with CFRP systems under sustained loading and different environmental conditioning10.1016/j.engstruct.2025.121645 ↗
10. ACI Committee 440. ACI 440.2R-17: Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures. 2017.
11. S. Matthys, T. Triantafillou, T. Neff, 2019, FIB Bulletin NO. 90: Externally Applied FRP Reinforcement for Concrete Structures.
12. Effects of elevated temperature on near surface mounted and externally bonded FRP strengthening systems for concrete10.1016/j.cemconcomp.2012.10.003 ↗
13. Effect of elevated service temperature on bond between FRP EBR systems and concrete10.1016/j.compositesb.2008.06.004 ↗
14. Elevated temperature response of RC beams strengthened with NSM FRP bars bonded with cementitious grout10.1016/j.compstruct.2020.113182 ↗
15. Bond response of NSM CFRP strips in concrete under sustained loading and different temperature and humidity conditions10.1016/j.compstruct.2018.02.048 ↗
16. Reinforced concrete beams strengthened in flexure with near-surface mounted (NSM) CFRP strips: current status and research needs10.1016/j.compositesb.2017.07.072 ↗
17. Near-surface mounted FRP reinforcement: an emerging technique for strengthening structures10.1016/j.compositesb.2006.08.003 ↗
18. Externally bonded reinforcement side extended (EBRSE) technique to postpone debonding of FRP laminates in strengthened concrete elements
19. Bond between near-surface mounted fiber-reinforced polymer rods and concrete in structural strengthening
20. Bond strength of near-surface mounted frp strip-to-concrete joints10.1061/(ASCE)1090-0268(2007)11:4(401) ↗
21. Generic debonding resistance of EB and NSM plate-to-concrete joints10.1061/(ASCE)1090-0268(2007)11:1(62) ↗
22. Anchorage strength models for FRP and steel plates bonded to concrete10.1061/(ASCE)0733-9445(2001)127:7(784) ↗
23. Near-surface-mounted fiber-reinforced polymer reinforcements for flexural strengthening of concrete structures
24. Investigation of bond in concrete structures strengthened with near surface mounted carbon fiber reinforced polymer strips10.1061/(ASCE)1090-0268(2003)7:3(248) ↗
25. L. A review on retrofitting concrete members with near-surface mounted-fiber reinforced polymer composites
26. Flexural behaviour of indeterminate concrete beams reinforced with FRP bars10.1016/j.engstruct.2007.12.019 ↗
27. Bond behavior of near surface mounted CFRP rods under temperature cycling10.1016/j.engstruct.2017.01.057 ↗
28. Effects of different environmental conditions on the mechanical characteristics of a structural epoxy10.1016/j.compositesb.2015.10.036 ↗
29. Performance of postcured CFRP–strengthened reinforced concrete beams at elevated temperatures10.1061/(ASCE)CC.1943-5614.0000787 ↗
30. Bond response of NSM CFRP strips in concrete under sustained loading and different temperature and humidity conditions10.1016/j.compstruct.2018.02.048 ↗
31. Prestress transfer in NSM CFRP-strengthened RC structures under curing and service temperature effects: experimental validation and analytical modeling10.3390/polym17182492 ↗
32. Hosen M.A., Alengaram U.J., Jumaat M.Z., Sulong N.H.R., Mahfuz Ud Darain K. Glass Fiber Reinforced Polymer (GFRP) Bars for Enhancing the Flexural Performance of RC Beams Using Side-NSM Technique 2017. https://doi.org/10.3390/polym9050180.10.3390/polym9050180 ↗
33. An experimental study on reinforced concrete beams strengthened with prestressed near surface mounted CFRP strips10.1016/j.engstruct.2014.08.007 ↗
34. Flexural strengthening of RC beams with prestressed NSM CFRP rods – Experimental and analytical investigation10.1016/j.conbuildmat.2009.03.005 ↗
35. Shear strengthening of RC beams with prestressed NSM CFRP: influencing factors and analytical model10.1016/j.compstruct.2024.118262 ↗
36. Experimental and analytical flexural performances of reinforced concrete beams strengthened with post-tensioned near surface mounted basalt composite laminates10.1016/j.compositesb.2018.08.072 ↗
37. Post-tension near-surface mounted strengthening system for reinforced concrete beams with changes in concrete condition10.1016/j.compositesb.2018.12.149 ↗
38. A new bonding agent for the Near-surface mounted Fibre-reinforced polymer strengthening system for concrete structures
39. Strengthening of RC beams using prestressed fiber reinforced polymers – a review10.1016/j.conbuildmat.2015.02.051 ↗
40. Pandey · 2017
41. Nonlinear 2D Finite-Element Modeling of RC Beams Strengthened with Prestressed NSM CFRP Reinforcement
42. Tonelli D., Rossi F., Brighenti F., Verzobio A., Bonelli A., Zonta D. Prestressed concrete bridge tested to failure: the Alveo Vecchio viaduct case study. J Civ Struct Health Monit 123AD;13:873–899. 10.1007/s13349-022-00633-w.10.1007/s13349-022-00633-w ↗
43. Experimental investigation on nonlinear flexural behavior of post-tensioned concrete bridge girders with different grouting conditions and prestress levels10.1061/JBENF2.BEENG-6466 ↗
44. European Committee for Standardization. EN 1992–1-1 Eurocode 2: Design of Concrete Structures—Part I: General Rules and Rules for Buildings. 2002.
45. Ministero delle Infrastrutture e dei Trasporti. Aggiornamento delle Norme tecniche per le costruzioni. DM 17–01-2018 2018.
46. ACI Committee 437. 437.1R-07: Load Tests of Concrete Structures: Methods, Magnitude, Protocols, and Acceptance Criteria. 2007.
47. Galano S., Losanno D., Parisi F. Numerical Simulation of Post-tensioned Concrete Girders with Defective Grouting Including Local Stress-strain Tendons Response 2024. https://doi.org/10.1002/suco.202400416.10.1002/suco.202400416 ↗
48. Galano S., Losanno D., Miluccio G., Parisi F. Multidimensional Nonlinear Numerical Simulation of Post-tensioned Concrete Girders with Different Prestressing Levels 2023. https://doi.org/10.1002/suco.202300272.10.1002/suco.202300272 ↗
49. International Standard. ISO 527–5:2021: Plastics — Determination of Tensile Properties. Part 5: Test Conditions for Unidirectional Fibre-reinforced Plastic Composites. 2021.
50. ACI Committee 440. ACI 440.2R 17 - Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures. 2017.
51. Consiglio Nazionale delle Ricerche. CNR-DT 200 R1 - Guide for the Design and Construction of Externally Bonded FRP Systems. Roma: 2013.